Search NASA⌕ Search

Engineering topics

Reid, H.

Publications and source records attributed to Reid, H..

Instrumental uncertainties in radiative corrections for the MUSE experiment

The MUSE experiment at the Paul Scherrer Institute is measuring elastic lepton-proton scattering cross sections in a four-momentum transfer range from Q 2 of approximately 0.002–0.08 GeV 2 using positively and negatively charged electrons and muons. The extraction of the Born cross sections from the experimental data requires radiative corrections. Estimates of the instrumental uncertainties in those corrections have been made using the ESEPP event generator. The results depend in particular on the minimum lepton momentum that contributes to the experimental cross section and the fraction of events with hard initial-state radiation that is detected in the MUSE calorimeter and is excluded from the data. Furthermore, these results show that the angular-dependent instrumental uncertainties in radiative corrections to the electron cross section are less than 0.4% and are negligible for the muon cross section.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of muon and electron beams in the Paul Scherrer Institute PiM1 channel for the MUSE experiment

The MUon Scattering Experiment, MUSE, at the Paul Scherrer Institute, Switzerland, investigates the proton charge radius puzzle, lepton universality, and two-photon exchange, via simultaneous measurements of elastic muon-proton and electron-proton scattering. The experiment uses the PiM1 secondary beam channel, which was designed for high precision pion scattering measurements. We review the properties of the beam line established for pions. We discuss the production processes that generate the electron and muon beams, and the simulations of these processes. Simulations of the π/μ/e beams through the channel using TURTLE and G4beamline are compared. The G4beamline simulation is then compared to several experimental measurements of the channel, including the momentum dispersion at the intermediate focal plane and target, the shape of the beam spot at the target, and timing measurements that allow the beam momenta to be determined. Finally, we conclude that the PiM1 channel can be used for high precision π, μ, and e scattering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A liquid hydrogen target for the MUSE experiment at PSI

A 280 ml liquid hydrogen target has been constructed and tested here for the MUSE experiment at PSI to investigate the proton charge radius via simultaneous measurement of elastic muon–proton and elastic electron–proton scattering. To control systematic uncertainties at a sub-percent level, strong constraints were put on the amount of material surrounding the target and on its temperature stability. The target system was successfully operated during a commissioning run at PSI at the end of 2018. The target temperature was stable at the 0.01 K level. This indicates a density stability at the 0.02% level, which is about a factor of ten better than required.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Test and analysis of a Northrup collector controller

The collector controller was examined as a functioning control system that drives the Northrup collector from east to west to follow the sun then back to the east at sundown in readiness for the next sunrise. The major components were examined separately with particular emphasis placed on an analysis of the electronic drive circuit. Results are presented from hardware testing and analysis with recommended changes to improve the system.

Scott, D. R.↗