Search NASASearch

Engineering topics

Reinhardt, V.

Publications and source records attributed to Reinhardt, V..

Temperature averaging thermal probe

A thermal probe to average temperature fluctuations over a prolonged period was formed with a temperature sensor embedded inside a solid object of a thermally conducting material. The solid object is held in a position equidistantly spaced apart from the interior surfaces of a closed housing by a mount made of a thermally insulating material. The housing is sealed to trap a vacuum or mass of air inside and thereby prevent transfer of heat directly between the environment outside of the housing and the solid object. Electrical leads couple the temperature sensor with a connector on the outside of the housing. Other solid objects of different sizes and materials may be substituted for the cylindrically-shaped object to vary the time constant of the probe.

Kalil, L. F.

Temperature-Averaging Thermal Probe

Temperature-averaging thermal probe measures long-term temperature fluctuations in fluid environment. Consists of temperature probe embedded inside thermally massive material. Probe measurements used to estimate powerplant heating and cooling loads, map temperature profiles, and calibrate more-sensitive temperature probes.

Kalil, L. F.

Recent results on the peformance of EFOS, NP and NX hydrogen masers

In response to a NASA Goddard Space Flight Center Work Assignment, Bendix Field Engineering Corporation evaluated the performance of the Oscilloquartz EPOS-2 hydrogen maser along with that of NASA NX-3 and NP-2 hydrogen masers in early 1983. This paper presents the results of that evaluation.

Reinhardt, V.

Hydrogen-maser frequency standard

Wall shift in frequency of proposed variable-shift maser that is caused by collisions between hydrogen atoms and container walls, could easily be determined, thereby allowing building of frequency standard with accuracy of 1 part in 10 to 14th power.

Reinhardt, V.

Femtosecond time-domain phase comparator

Phase shift in test device is measured by summing output of mixer with ramp voltage and comparing time interval between zero crossings of summed signal and ramp reference frequency. Circuit can be used to test devices at other frequencies by changing only signal source, phase splitter, and mixer; divider and time-interval counter need not be driven by oscillator.

Donahoe, T.

Frequency stability requirements for two way range rate tracking

Accuracy limitations to two way range rate Doppler tracking due to master (reference) oscillator frequency instabilities are discussed. Theory is developed to treat both the effects of random and nonrandom oscillator instabilities. The nonrandom instabilities treated are drift, environmental effects, and coherent phase modulation. The effects of random instabilities on range rate accuracy are shown to be describable in terms of sigma y (2, T, tau). For the typical noise processes encountered in precision oscillators, range rate error is related to the more familiar sigma y (tau) and script L (f). Three examples are discussed to show how to determine range rate error from given sigma y (tau) or script L (f) curves, and approximations are developed to simplify the treatment of complex systems. An error analysis of range determined from rate data is also given.

Reinhardt, V.

Relativistic effects of the rotation of the earth on remote clock synchronization

A treatment is given of relativistic clock synchronization effects due to the rotation of the earth. Unlike other approaches, the point of view of an earth fixed coordinate system is used which offers insight to many problems. An attempt is made to give the reader an intuitive grasp of the subject as well as to provide formulae for his use. Specific applications to global timekeeping, navigation, VLBI, relativistic clock experiments, and satellite clock synchronization are discussed. The question of whether atomic clocks are ideal clocks is also treated.

Reinhardt, V.

Flexible bulb large storage box hydrogen maser

The principal limitation on the accuracy of the hydrogen maser as a primary frequency standard has been the irreproducibility of the frequency shift caused by collisions of the radiating atoms with the walls of the vessel containing them. The flexible bulb-large storage box hydrogen maser allows correction for this wall shift within a single device, sidestepping the reproducibility problem, and reducing the frequency error from the wall shift to the level imposed by the device's stability. The principles of the device are discussed including the flexible bulb technique and the complications caused by a multiple region storage bulb. The stability of the device is discussed including a comparison with an ordinary hydrogen maser. Data is presented from a working flexible bulb-large storage box hydrogen maser demonstrating the feasibility of the device and showing some of its operating characteristics. The flexibility of the device is demonstrated by showing how the device's added degrees of freedom allow measurement of parameters unmeasurable in an ordinary hydrogen maser.

Reinhardt, V.