Search NASA⌕ Search

Engineering topics

Reinking, Zachary

Publications and source records attributed to Reinking, Zachary.

Design of a gas-solid-solid separator to remove ash from circulating fluidized bed reactors

Cyclones are one of the most common types of gas-solid separators used in circulating fluidized bed boilers. However, cyclones typically do not allow ash to leave the system through the cyclone exit, causing ash to build up in the fluidized bed and necessitating additional systems to remove ash that builds up in the bed. In this study, an alternative “disengager” gas-solid separator is proposed as a way of inherently separating small and large solids, resulting in a gas-solid-solid separation system where ash is allowed to leave the system along with gas while the desired fluidized bed material is retained. Unlike cyclones, which rely on centrifugal force to separate solids and gas, the disengager separates based on entrainment velocity of the particles. Upwards-flowing gas and particles strike a deflection plate and enter the disengaging chamber where particles with low terminal velocity such as ash fines flow with the gas, while larger particles such as sand fall to the bottom of the separator and are returned to the fluidized bed. In this study, several different proposed disengager configurations are simulated and compared to a typical cyclone using computational fluid dynamic (CFD) simulations. Furthermore, it was found that separation efficiency in the disengager is strongly influenced by the size of the deflection plate, rather than by the size of the unit itself. The predicted separation efficiency showed that compared to a cyclone, the disengager design allows significantly more ash to exit the system but retains a similar amount of desirable material. Additionally, the disengager was predicted to not suffer significantly more erosion that a cyclone.

42 ENGINEERING↗

A simulation-based parametric study of CLOU chemical looping reactor performance

Chemical looping with oxygen uncoupling (CLOU) is a variant on chemical looping combustion in which the oxygen carrier releases gaseous O 2 in the fuel reactor, making it well-suited for solid fuels, since the released gaseous O 2 readily reacts with solid char. This work presents several computational fluid dynamic (CFD) simulations of copper-based CLOU in a dual fluidized bed system, each with different operating conditions. The modeling predicted that coal particle sizes as large as 1000 μm did not significantly affect performance. Increased oxygen carrier copper loading resulted in an excess of gaseous oxygen in the product gas stream. Decreasing the oxygen carrier bed mass as well as reducing the air reactor fluidizing velocity did not supply enough oxygen to the fuel reactor to complete combustion of the coal. This generated a failure state in which the temperature continued to decrease in the fuel reactor from the lack of combustion, which in turn reduced the O 2 equilibrium partial pressure, further lowering the amount of combustion possible. Sufficient O 2 can be maintained in the fuel reactor by ensuring a high enough air reactor velocity and a large enough supply of oxygen carrier inventory to handle the chosen coal feed rate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational simulation of a 100 kW dual circulating fluidized bed reactor processing coal by chemical looping with oxygen uncoupling

Chemical looping with oxygen uncoupling (CLOU) is a promising carbon capture technology that utilizes two interconnected fluidized-bed reactors to separate oxygen from air using a metal oxide, and then to use that oxygen to combust fuel in a nitrogen-free environment. CLOU is particularly well suited for solid fuels such as coal since released O 2 will readily combust with solid char. This study presents simulations of the University of Utah's dual fluidized bed chemical looping process development unit (PDU) operating as a CLOU system at 100 kW th , using CPFD Software's Barracuda-VR™ CFD modeling program. A full 3D model of the PDU was used including both reactors, as well as loop seals and cyclone separators. Hydrodynamic settings and the drag model are based on previous cold-flow validation experiments. Mechanisms describing CLOU reaction kinetics for cuprous oxide oxidation in the air reactor and cupric oxide reduction in the fuel reactor were adapted from previously completed experimental work. Coal char kinetics were based on the carbon-hydrogen-nitrogen-oxygen-sulfur, CHNOS, method. Submodels for devolatilization, gasification, and homogenous gas-phase reactions used relationships from the literature. Results predict volatile burnout almost immediately, though coal combustion continues into the upper portions of the fuel reactor and cyclone. Lastly, nitrogen gas leakage into the fuel reactor is shown to be mostly carryover from the air reactor

42 ENGINEERING↗

Prediction of Performance of a Pilot Scale Dual Fluidized Bed System for Chemical Looping with Oxygen Uncoupling

Chemical looping with oxygen uncoupling (CLOU) is a variant of chemical looping combustion that involves spontaneous release of gaseous oxygen in the fuel reactor, which enables efficient combustion of solid fuel char. The University of Utah has constructed a pilot-scale dual fluidized bed chemical looping process development unit (PDU) with a nominal thermal input of 200 kW. The CLOU oxygen carrier uses copper as the active metal, cycling between cupric (CuO) and cuprous (Cu2O) oxides. As an aid for design, troubleshooting and evaluation of the pilot system, a CFD model has been developed using CPFD Software’s Barracuda VR software. The 3D model includes both reactors, as well as loop seals and cyclone separators. Mechanisms describing CLOU reaction kinetics for cuprous oxide oxidation in the air reactor and cupric oxide reduction in the fuel reactor were adapted from previously done experimental work. Coal char kinetics were based on the carbon-hydrogen-nitrogen-oxygen-sulfur, CHNOS, method. Submodels for devolatilization, gasification, and homogenous gas-phase reactions used preexisting relationships in the literature. Results predict temperature profiles, concentration profiles, product gas composition, and CO¬2 capture efficiency. This paper presents results of a parametric study in which key operational variables were adjusted to determine the influence on simulated performance of the PDU. The adjusted variables include fuel feed rate, fuel particle size, total oxygen carrier inventory, oxygen carrier copper oxide loading, and oxygen carrier particle physical properties.

Reinking, Zachary↗

Prediction of Performance of a Pilot-Scale Dual Fluidized Bed System for Chemical Looping with Oxygen Uncoupling

Chemical looping with oxygen uncoupling (CLOU) is a variant of chemical looping combustion that involves spontaneous release of gaseous oxygen in the fuel reactor, which enables efficient combustion of solid fuel char. The University of Utah has constructed a 200 kW pilot-scale chemical looping process development unit (PDU) consisting of two fluidized beds. The CLOU oxygen carrier uses copper as the active metal, cycling between cupric (CuO) and cuprous (Cu2O) oxides. As an aid for design, troubleshooting and evaluation of the pilot system, a CFD model has been developed using CPFD Software’s Barracuda VR software. The 3D model includes both reactors, as well as loop seals and cyclone separators. Mechanisms describing CLOU reaction kinetics for cuprous oxide oxidation in the air reactor and cupric oxide reduction in the fuel reactor were adapted from previously reported experimental work. Coal char kinetics were based on the carbon-hydrogen-nitrogen-oxygen-sulfur, CHNOS, method. Submodels for devolatilization, gasification, and homogenous gas-phase reactions used preexisting relationships in the literature. Three different simulations were performed, analyzing the influence of particle properties (a base carrier and an alternate carrier referred to as cariact) and coal feeding rate (100kW, 200kW). Increased coal feeding rate caused significant increase in cuprious oxide oxidation in the air reactor as well as higher temperature. The alternate carrier predicted CO2 capture below 90%, in contrast to the other cases.

Reinking, Zachary↗