High-temperature chemical expansion of Pr0.1Ce0.9O2-δ thin films determined by Differential Laser Doppler Vibrometry

The chemical expansion of thin-film praseodymium-cerium oxide solid solutions (Pr 0.1 Ce 0.9 O 2-δ , PCO10) is investigated at temperatures ranging from 500 °C to 800 °C and oxygen activities down to about 10 -22 . Differential Laser Doppler Vibrometry (D-LDV) in combination with periodic electrochemical pumping of oxygen is used to detect very small displacements of the sample surface. With decreasing pumping frequency, the film approaches chemical equilibrium, which is nearly reached at 700 °C below 0.01 Hz. D-LDV enables direct measurement of film thickness changes as well as the bending of the underlying substrates due electrochemically induced lateral mechanical stress. The substrate bending is found to be more than an order of magnitude larger than the film thickness change, increasing the detection limit by the same factor. The thickness change of the thin film is calculated from the measured displacement of the sample surface and compared with directly measured values. Thin-film literature data available for low oxygen activities up to 650 °C agree with our measurements. In addition, the thickness change of the film is determined from the displacement at different sample positions, which validates previous measurements. Finally, thin film chemical expansion is found to be larger by a factor of about 2 than the corresponding bulk value in agreement with predictions from a mechanical model that the out-of-plane expansion of a constrained film is increased.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Approaching attometer laser vibrometry

The heterodyne two-beam interferometer has been proven to be the optimal solution for laser-Doppler vibrometry regarding accuracy and signal robustness. The theoretical resolution limit for a two-beam interferometer of laser class 3R (up to 5 mW visible measurement-light) is in the regime of a few femtometer per square-root Hertz and well suited to study vibrations in microstructures. However, some new applications of RF-MEM resonators, nanostructures, and surface-nano-defect detection require resolutions beyond that limit. The resolution depends only on the noise and the sensor sensitivity to specimen displacements. The noise is already defined in nowadays systems by the quantum nature of light for a properly designed optical sensor and more light would lead to an inacceptable influence like heating of a very tiny structure. Thus, noise can only be improved by squeezed-light techniques which require a negligible loss of measurement light which is impossible for almost all technical measurement tasks. Thus, improving the sensitivity is the only possible path which could make attometer laser vibrometry possible. Decreasing the measurement wavelength would increase the sensitivity but would also increase the photon shot noise. In this paper, we discuss an approach to increase the sensitivity by assembling an additional mirror between interferometer and specimen to form an optical cavity. A detailed theoretical analysis of this setup is presented and we derive the resolution limit, discuss the main contributions to the uncertainty budget, and show a first experiment proving the sensitivity amplification of our approach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗