Ren, Xi

Publications and source records attributed to Ren, Xi.

Considerations for in situ, real time measurement of plasma-material interactions using Digital Holographic imaging

Digital Holographic (DH) imaging is a laser-based measurement technique, which can be used to monitor a material surface as it is being exposed to fusion-relevant plasmas. Both single-laser and dual-laser DH measurements have been demonstrated ex situ at Oak Ridge National Laboratory (ORNL). A DH diagnostic system is being assessed for deployment at ORNL to make in situ, real-time measurements of plasma erosion/redeposition in the Prototype Material Plasma Exposure eXperiment (Proto-MPEX). In situ, real time measurements pose unique challenges to diagnostic systems, which are not encountered by ex situ analysis techniques. The absolute surface height (tracked at the nm to μm position) during plasma exposure can be modified by: 1) surface movement due to vibration or thrust exerted by the plasma device, 2) surface growth due to the thermal expansion of the material under steady MW/m2 or transient GW/m2 plasma heat loads, and 3) surface modification due to plasma erosion/redeposition of the material substrate. To assess these effects, 1) the vibration spectrum of the diagnostic and the pulsed plasma device have been measured, 2) the thermal growth of the surface has been measured for an applied heat flux, and 3) the surface modification has been measured ex situ post plasma exposure, and ex situ post laser ablation as a proxy for the plasma. This paper will provide an overview of the results that have been achieved in the development of a DH diagnostic for in situ real-time measurements of plasma exposed surfaces in the Proto-MPEX device.

Biewer, Theodore↗

Recent Developments in Dual-Laser Digital Holography for Plasma-Facing Surface Characterization

A digital holography device is currently undergoing development at the Oak Ridge National Laboratory for the purpose of measuring surface topography, with the goal of deployment as a real-time plasma-facing component diagnostic for the study of materials that could be utilized in a nuclear fusion device. The holography system utilizes one or two lasers depending on the scale of surface features under measurement. Measurements of surface roughness were performed in a single-laser mode and compared with the data from profilometry, with a linear correlation of increased holographic measurement fidelity as surfaces became smoother. Characterization of the dual-laser operating mode has been performed via surface measurement of stainless steel targets with ``stair-step'' features in various sizes. Results demonstrated that surface features with known sizes as small as 25.4 μm could be resolved. Measurements were within ~55 μm or less deviation from the actual sizes, and measurement accuracy was improved as feature size was increased, corresponding to the effect of noise becoming less pronounced. In conclusion, a target exposed to plasma generated by an electrothermal (ET) arc source was analyzed with flat-field correction and averaging of sequential image frames to demonstrate the improved measurement quality in preparation for future use of holography on ET arc-exposed targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗