Search NASA⌕ Search

Engineering topics

Rescia, S.

Publications and source records attributed to Rescia, S..

Characterization of the ATLAS Liquid Argon Front-End ASIC ALFE2 for the HL-LHC upgrade

In this study, ALFE2 is an ATLAS Liquid Argon Calorimeter (LAr) Front-End ASIC designed for the HL-LHC upgrade. ALFE2 comprises four channels of pre-amplifiers and CR-(RC) 2 shapers with adjustable input impedance. ALFE2 features two separate gain outputs to provide 16-bit dynamic-range coverage and an optimum resolution. ALFE2 is characterized using a Front-End Test Board (FETB) based on a Zynq UltraScale+ MPSoC and two octal-channel 16-bit high-speed ADCs. The test results indicate that ALFE2 fulfills or greatly exceeds all specifications on gain, noise, linearity, uniformity, and radiation tolerance.

47 OTHER INSTRUMENTATION↗

Studies of event burst phenomenon with SiPMs in liquid nitrogen

Silicon photomultiplier (SiPM) are used to collect scintillation photons in many cryogenic noble liquid detectors deployed around the world, such as DarkSide, nEXO, MEGII, ProtoDUNE and DUNE. An event burst phenomenon was observed during routine characterization on many models of SiPMs operated in liquid nitrogen. These bursts of consecutive pulses are initiated by an intense dark photoelectron pulse with an event rate much lower than the time-uncorrelated thermal dark pulse. Although the rate of these burst events is very low, it can potentially compromise some dedicated rare physics event searches which are also anticipated to be of extremely low rate. Here, we systematically studied the behavior of the event burst phenomenon and identified the probable cause of the phenomenon. Here, this investigation is important for the selection of SiPMs for use in noble liquid detectors, high energy physics experiments, and industrial applications where SiPMs are used in cryogenic environment.

47 OTHER INSTRUMENTATION↗

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0νββ), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0νββ of 136 Xe with projected half-life sensitivity of 1.35 x 10 28 yr. To reach this sensitivity, the design goal for nEXO is ≤1% energy resolution at the decay Q-value (2458.07 ± 0.31 keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163 K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay Q-value for the nEXO design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and R&D of RICH detectors for EIC experiments

An Electron-Ion Collider (EIC) has been proposed to further explore the strong force and QCD, focusing on the structure and the interaction of gluon-dominated matter. A generic detector R& D program (EIC PID consortium) for the particle identification in EIC experiments was formed to explore technologically advanced solutions in this scope. In this context two Ring Imaging Cherenkov (RICH) counters have been proposed: a modular RICH detector which consists of an aerogel radiator, a Fresnel lens, a mirrored box, and pixelated photon sensor; a dual-radiator RICH, consisting of an aerogel radiator and C 2 F 6 gas in a mirror-focused configuration. We present the simulations of the two detectors and their estimated performance.

electron-ion collider↗

Modular focusing ring imaging Cherenkov detector for electron–ion collider experiments

A powerful new electron-ion collider (EIC) has been recommended in the 2015 Long Range Plan for Nuclear Science for probing the partonic structure inside nucleons and nuclei with unprecedented precision and versatility [1]. EIC detectors are currently under development [2], all of which require hadron identification over a broad kinematic range. A prototype ring imaging Cherenkov detector has been developed for hadron identification in the momentum range from 3 GeV/c to 10 GeV/c. The key feature of this new detector is a compact and modular design, achieved by using aerogel as radiator and a Fresnel lens for ring focusing. In this paper, the results from a beam test of a prototype device at Fermilab are reported.

aerogel↗

A Storage Ring Experiment to Detect a Proton Electric Dipole Moment

A new experiment is described to detect a permanent electric dipole moment of the proton with a sensitivity of 10−29 e ⋅ cm by using polarized “magic” momentum 0.7 GeV/c protons in an all-electric storage ring. Systematic errors relevant to the experiment are discussed and techniques to address them are presented. The measurement is sensitive to new physics beyond the standard model at the scale of 3000 TeV.

43 PARTICLE ACCELERATORS↗

Evaluation of commercial ADC radiation tolerance for accelerator experiments

Electronic components used in high energy physics experiments are subjected to a radiation background composed of high energy hadrons, mesons and photons. These particles can induce permanent and transient effects that affect the normal device operation. Ionizing dose and displacement damage can cause chronic damage which disable the device permanently. Transient effects or single event effects are in general recoverable with time intervals that depend on the nature of the failure. The magnitude of these effects is technology dependent with feature size being one of the key parameters. Analog to digital converters are components that are frequently used in detector front end electronics, generally placed as close as possible to the sensing elements to maximize signal fidelity. We report on radiation effects tests conducted on 17 commercially available analog to digital converters and extensive single event effect measurements on specific twelve and fourteen bit ADCs that presented high tolerance to ionizing dose. We discuss mitigation strategies for single event effects (SEE) for their use in the large hadron collider environment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Long-Baseline Neutrino Experiment (LBNE)

The US department of energy approved the Mission Need (CD-0) for a long baseline neu trino experiment on January 8th 2010. This marked the official start of the LBNE project whose goal is to plan and execute the construction of a next generation neutrino experiment designed to measure neutrino oscillation parameters with a neutrino beam from Fermilab detected in a large detector a mile underground in the former Homestake mine in South Dakota.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗