Search NASA⌕ Search

Engineering topics

Reusch, Joshua A.

Publications and source records attributed to Reusch, Joshua A..

At least 19 records

Effects of Injected Current Streams on MHD Equilibrium Reconstruction of Local Helicity Injection Plasmas in a Spherical Tokamak

Open field line currents are intrinsic to DC helicity injection plasma startup and pose a challenge for inferring the plasma equilibrium with standard reconstruction analysis. Local helicity injection (LHI) is a type of DC helicity injection which uses small, modular current sources to drive force-free current along helical field lines to produce tokamak plasmas. MHD modeling and magnetic measurements during LHI indicate the injected current streams remain coherent as helical structures on the outboard edge of a core toroidal plasma that is tokamak-like in a toroidally averaged sense. To extract core plasma equilibrium properties, external magnetic diagnostics corrected for contributions from the injected current streams are fitted by a standard Grad-Shafranov equilibrium code. An iterative approach for estimating and subtracting the stream contributions from the diagnostic signals is described and applied to a model equilibrium database to reduce systematic errors introduced by the streams. Convergence is usually attained with 2 to 4 iterations, with derived equilibrium parameters matching the prescribed axisymmetric core values to within estimated experimental uncertainties. Accurate recovery of core parameters occurs when the ratio of the net toroidal windup current from the streams to the core plasma current is less than 0.2, which is typically satisfied in most experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A magnetic diagnostic suite for the Pegasus-III experiment

Pegasus-III is an ultralow aspect ratio spherical tokamak providing a dedicated US experiment for comparative solenoid-free startup studies. A new magnetic diagnostic suite for equilibrium and low frequency (<200 kHz) magnetohydrodynamic mode analysis has been installed. These new diagnostics address the significant challenges of measuring magnetic field in a high noise environment with the majority constrained to fit in an 8 mm diagnostic gap on the high field side. Electrostatic switching noise generated by the 16 independent current feedback-controlled power supplies produces dV cm /dt ~ 1 kV/μs and volt level common mode noise on the magnetics. Immunity to this switching noise is accomplished through differential signal runs and signal processing, along with end-to-end electromagnetic interference shielding. The magnetic measurements are simultaneously digitized at 1 MHz and conditioned by precision 8 pole Butterworth filters with a corner frequency of 200 kHz to prevent aliasing down to the 16-bit level over the full passband. Ex-vessel calibrations of the B p coils were completed with a typical uncertainty of <0.5%. Stray toroidal field pickup from coil misalignment or positioning errors is corrected using a physics-based model. Comparisons of the corrected measurements to modeling agree to within 1.3% on average. This is within the 1.5% measurement uncertainty that a sensitivity analysis determined is needed for accurate fast boundary and equilibrium reconstruction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementation of an impurity diagnostic suite on the Pegasus-III experiment

A suite of diagnostics used to assess impurity content and dynamics has been updated, upgraded, and installed on the Pegasus-III Experiment. Typical plasma parameters during local helicity injection start-up are τ shot ~10 ms, n e ~ 1 × 10 19 m –3 , and T e ~ 50 eV. The deployed diagnostics are compatible with this modest temperature and density regime and provide species identification, source localization, and estimation of radiation losses. Impurity species are determined by recording time-evolving, single line-of-sight spectra at 1.25 kfps using a SPRED (Survey, Poor Resolution, Extended Domain) vacuum ultraviolet spectrometer. SPRED is equipped with 450 g/mm grating, giving a spectral resolution of 0.33 nm and a spectral range from ~10 to 110 nm, useful to identify light impurity species in this temperature and density range. An absolutely calibrated spectrometer that collects light from the plasma at R tan = 15.9 cm and Δt ≥ 2 ms is used as a visible survey spectrometer and for continuum measurements. The radiated power from the plasma is estimated with a photodiode-based diagnostic. Two 16-channel absolute extreme ultraviolet diode arrays are placed behind pinhole apertures, resulting in 32 lines of sight at Z = 0, with a spatial resolution of 2–3 cm and a time response of 60 kHz. A photometrically calibrated collinear D α /near infrared filtered photodiode-based system measures the D α emission and around 1040 nm. All these instruments have been designed to suppress electromagnetic interference from megawatt-class switching power supplies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

$\mathrm{T}$ransient $\mathrm{CHI}$ System Design Studies for $\mathrm{P}$ EGASUS -$\mathrm{III}$

We report transient coaxial helicity injection (transient CHI), first developed on the Helicity Injected Torus-II (HIT-II) and later on the National Spherical Torus Experiment (NSTX) for implementing solenoid-free plasma current startup capability in a spherical tokamak (ST), is now planned to be tested on the Pegasus-III ST using a novel double-biased configuration. Such a configuration is likely needed for transient CHI deployment in a reactor. The transient CHI system optimization will be studied on Pegasus-III to enable startup toroidal persisting currents at the limits permitted by the external poloidal field coils. A transient CHI discharge is generated by driving injector current along magnetic field lines that connect the inner and outer divertor plates on one end of the ST. Simulations using the Tokamak Simulation Code are used to assess the transient CHI toroidal current generation potential and electrode gap location on the Pegasus-III. While past transient CHI systems have used high-voltage, oil-filled capacitors for driving the injector current, for improved safety, Pegasus-III will use a high-current capacitor bank based on low-voltage electrolytic capacitors. The designed and fabricated system is capable of over 32 kA. The modular design features permit the system to be upgraded to higher currents, as needed, to meet the future needs of the Pegasus-III facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Erratum: “On virial analysis at low aspect ratio” [Phys. Plasmas 23, 072508 (2016)]

This article corrects an error in M.W. Bongard et al., 'On Virial Analysis at Low Aspect Ratio,' Phys. Plasmas 23, 072508 (2016) pertaining to a typographical error in its equation 21. Furthermore, all numerical calculations reported in this paper utilized the correct formulation described here. Accordingly, no changes to the conclusions of the original article are required.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advancing local helicity injection for non-solenoidal tokamak startup

Experiments on the A ~ 1 PEGASUS ST are advancing the physics and technology basis of Local Helicity Injection (LHI). LHI injects helicity with relatively intense electron current sources in the plasma edge. It creates high toroidal current, toroidally-averaged tokamak-like plasmas that have been efficiently transitioned to Ohmically driven tokamak plasmas. Tradeoffs between physics and engineering goals are tested with LHI systems on the low-field-side and the high-field-side of PEGASUS, producing plasmas predominantly driven by non-solenoidal induction and DC helicity drive, respectively. An extensive LHI source development campaign comparing active arc sources, passive and gas-effused electrode sources lead to the selection of active arc sources for present and next-step LHI deployments. LHI plasmas with net toroidal current I p =0.225 MA, T e >100 eV, and n e ~ 10 19 m -3 are attained to date. A predictive 0D power-balance model describes experimental I p (t) and partitions the active current drive sources. High-frequency MHD activity is found to be present during LHI current drive, in addition to n=1 modes previously found in NIMROD simulation and experiment. A new system of reduced MHD activity was detected where n=1 activity is suppressed, LHI CD efficiency improves, and long-pulse plasmas are sustained with V IND ~ 0.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radially scanning magnetic probes to study local helicity injection dynamics

Two new magnetic probes have been deployed on the Pegasus spherical tokamak to study the dynamics of local helicity injection non-solenoidal plasma start-up and current drive. The magnetic radial array probe consists of 15 pickup coils (~5 × 8 mm each) that measure B z (R) over a 15 cm linear extent. The coils consist of traces embedded in a printed circuit board. Three coil designs are utilized to balance frequency response and coil sensitivity. Helmholtz coil measurements are used to measure coil and full assembly bandwidths (~2 MHz and ~200 kHz, respectively) and sensitivities (0.18/0.35/0.96 mV T -1 s). The magnetic radial scanning probe is an array of Hall effect sensors that measure field strength ( |B| 177 mT) and direction at 8 spatial points (ΔR = 1.5 cm), supporting the studies of equilibrium field structure and low-frequency (≤5 kHz) current dynamics. It uses commercial surface-mount Hall effect sensors with chip-integrated amplifiers and compensators that are mounted in a 3-D printed frame. Helmholtz coil measurements indicate negligible cross-field gain nonlinearity and provide absolute calibration of the diagnostic. Both probes are constructed as an electrostatically shielded insertable air-side assembly that mounts within a radially translatable ultrahigh vacuum assembly from an existing probe.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Initiation and sustainment of tokamak plasmas with local helicity injection as the majority current drive

Local helicity injection (LHI) is a non-solenoidal current drive capable of achieving high- I p tokamak startup with non-invasive current injectors in the plasma scrape-off layer. The choice of injector location within the edge region is flexible but has a profound influence on the nature of the current drive in LHI discharges. New experiments on the Pegasus ST with injection in the high-field-side, lower divertor region produce plasmas dominated by helicity injection current drive, static plasma geometry, and negligible inductive drive. Peak plasma current up to 200 kA, and a sustained plasma current of 100 kA for up to 18 ms, is demonstrated. Maximum achievable plasma current is found to scale approximately linearly with the effective loop voltage from LHI. A newly-observed MHD regime for LHI-driven plasmas in which large-amplitude n = 1 fluctuations at 20–50 kHz are abruptly reduced on the outboard side results in improved current drive. In conclusion, a simultaneous increase in high frequency fluctuations (>400 kHz) inside the plasma edge suggests short wavelength turbulence as an important current drive mechanism during LHI.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A power-balance model for local helicity injection startup in a spherical tokamak

A 0D circuit model for predicting I p ( t ) in Local Helicity Injection (LHI) discharges is developed. Analytic formulas for estimating the surface flux of finite-A plasmas developed are modified and expanded to treat highly shaped, ultralow-A tokamak geometry using a database of representative equilibria. Model predictions are compared to sample LHI discharges in the A ~ 1 Pegasus spherical tokamak, and are found to agree within 15% of experimental I p ( t ). High performance LHI discharges are found to follow the Taylor relaxation current limit for approximately the first half of the current ramp, or I p ≲ 75 kA. The second half of the current ramp follows a limit imposed by power-balance as plasmas expand from high- A to ultralow- A . Here, this shape evolution generates a significant drop in external plasma inductance, effectively using the plasma’s initially high inductance to drive the current ramp and provide > 70% of the current drive V-s. Projections using this model indicate the relative influences of higher helicity input rate and injector current on the attainable total plasma current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗