Search NASA⌕ Search

Engineering topics

Reverchon, Jean-Luc

Publications and source records attributed to Reverchon, Jean-Luc.

X-ray detectors based on GaN Schottky diodes

GaN Schottky diodes have been fabricated and tested as x-ray detectors in the range from 6 to 21 keV. The spectral response has been measured and is compared to its theoretical value. The study of the response and its temporal dynamics as a function of the bias allows to identify a photovoltaic behavior at low bias and a photoconductive one at larger reverse biases. The GaN diode turned out to be linear as a function of the incident power. The noise and detectivity are given and discussed.

36 MATERIALS SCIENCE↗

Anomalous photoresponse of GaN x-ray Schottky detectors

GaN based materials are believed to be very stable materials, in particular, under irradiation by high energy photons such as x rays. We have studied x-ray detectors based on GaN Schottky diodes. Vertical Schottky diodes were fabricated based on a 20 mum thick undoped GaN layer grown on a conductive GaN substrate. Their photoresponse to near UV light and to x rays was measured. While the response to near UV light was fast and linear as expected, anomalous behaviors were observed under x-ray illumination. The photocurrent increases as the third power of the incident x-ray flux. The photocurrent transient when the x rays is turned on are long and nonexponential (S shape) and strongly differs from the off transient which is fast and exponential. Also, a very strong quenching of the x-ray photoresponse is observed when the detector is simultaneously illuminated with visible light. All of these anomalous behaviors are explained in the frame of a complete model involving traps and tunnel currents. A reasonable quantitative agreement between the model and the experimental data is obtained.

36 MATERIALS SCIENCE↗

GaN for x-ray detection

The potential of GaN based materials for x-ray detection is investigated. The absorption coefficient in GaN is measured as a function of photon energy between 6 and 40 keV. Metal-semiconductor-metal photodetectors are fabricated and characterized. The response dependence on bias, the temporal dynamics, and the response dependence on detector geometry all together point toward a mixing of photovoltaic and photoconductive effects. Thanks to a large photoconductive gain, the detector has a decent responsivity at the expense of a large response time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗