Search NASASearch

Engineering topics

Richard, J.-P.

Publications and source records attributed to Richard, J.-P..

Optical motion sensor for resonant-bar gravitational wave antennas

An experiment is described in which an optical method was used to measure fluctuations in the separation between two mirrors of a Fabry-Perot sensor cavity. Noise measurements were made to determine the sensitivity of this device to vibration amplitudes in the frequency range 1.1-2.1 kHz, which is of interest for resonant-bar gravitational wave antennas. The rms spectral noise density for length fluctuations in this range was sq rt 3.7 x 10 exp -15 m/Hz and can be related to electronic noise of the circuitry plus vibrational noise from the environment. The cavity finesse was relatively low at 117, and the power dissipated in the mirrors was estimated to be 1.9 micro-W. On a multimode gravitational wave detector, the sensor cavity would be formed by one reference mirror and by one mirror mounted on the last resonator. For a 1200-kg bar, 1.2-g last resonator system operating at 1600 Hz the sensor described here would exhibit a noise temperature of 18 micro-K; the resolution in h in the case of negligible thermal noise from the mechanical system would be sq rt 3.7 x 10 exp -18/Hz. Improvements in the sensitivity in a quiet antenna-like environment should be possible with higher finesse mirrors.

Richard, J.-P.

Cryogenic monocrystalline silicon Fabry-Perot cavity for the stabilization of laser frequency

A 1.6 kg silicon monocrystal was used to make a Fabry-Perot optical cavity operated at cryogenic temperatures. High-resolution thermal expansion measurements were made as the silicon cooled to 4.2 K, in order to characterize the cavity as a length reference standard. A helium-neon laser was then locked to a transmission resonance at liquid-helium temperatures, and the laser frequency tracked the cavity resonance with error fluctuations at the level of 10 Hz/sq rt Hz in the bandwidth dc to 1 Hz. Implications of the combined set of data, thermal expansion plus frequency-tracking fluctuations, for using such a system as a frequency standard are discussed.

Richard, J.-P.

Measurement of a high electrical quality factor in a niobium resonator for a gravitational radiation detector

The mechanical and electrical quality factors of a 10-g niobium resonator were measured at 4.4 K and were found to be 8.1 x 10 to the 6th, and 3.8 x 10 to the 6th, respectively. The value for the electrical quality factor is high enough for a system operating at 50 mK at a sensitivity level of one phonon. The resonator's low damping properties make it suitable for use as a transducer for a cryogenic three-mode gravitational radiation detector. A practical design is given for the mounting of the resonator on a 2400-kg aluminum-bar detector. Projections are made for the sensitivity of a 2400-kg bar instrumented as a three-mode system with this resonator inductively coupled to a SQUID.

Folkner, W. M.

Very high-vacuum heat treatment facility

A vacuum heat treatment facility, with hot zone dimensions of 12 x 19 x 19 cm, has been designed and constructed at a cost substantially below that of a commercial unit. The design incorporates efficient water cooling and a resistive heating element. A vacuum pressure of 1.5 x 10 to the -8th torr at room temperature has been obtained after baking. The temperature limit is approximately 1900 C. This limit results from the choice of niobium as the hot zone material.

Folkner, W. M.

Monocrystals for the investigation of gravity phenomena

The usefulness for gravity experiments of monocrystals with very high mechanical quality factors is reviewed. Measurements carried on four point mechanical suspensions at liquid helium temperature are reported. Qs of 400 x 10 to the 6th have been measured for the longitudinal mode of sapphire and ruby crystals. A Q of 80 x 10 to the 6th was measured for the bending mode of a silicon crystal.

Richard, J.-P.

Recent developments in the measurement of space time curvature

Development of a highly sensitive resonant capacitor displacement sensor and a multistage suspension system for a low-temperature gravitational radiation antenna is discussed; the antenna is suitable for studying gravitational collapses. The sensitivity limit of the device is assessed as a function of preamplifier noise. Experiments indicate that an electric field of about 160,000 v/cm may be applied to the resonator surface without a significant increase in Brownian noise. Use of the resonant capacitor sensor with very high Q antennae is also considered.

Richard, J.-P.

Best-fit estimate of relativistic effects in time-delay experiments.

Time-delay experiments are analyzed within the frame of a curved space-time. Residuals from Newtonian best fits of relativistic data are used as a measure of the 'relativistic effects.' Radial transponder trajectories are considered. If the motion is towards the sun, the relativistic residuals are of the order of 100 m. If the motion is away from the sun, they are at the 10-km level and the fraction due to the second-order curvature of the metric is at the 1-km level. Those effects are significantly smaller than those calculated from the divergence of the Newtonian and relativistic predictions after exact fit of the initial measurements.

Richard, J.-P.