Search NASASearch

Engineering topics

Richter, R.

Publications and source records attributed to Richter, R..

At least 19 records

MAC Europe 1991: Evaluation of AVIRIS, GER imaging spectrometry data for the land application testsite Oberpfaffenhofen

During the MAC Europe 91 Campaign, the area of Oberpfaffenhofen including the land application testsite Oberpfaffenhofen was flown by the AVIRIS imaging spectrometer, the GER 2 imaging spectrometer (63 band scanner), and two SAR systems (NASA/JPL AIRSAR and DLR E-SAR). In parallel to the overflights ground spectrometry (ASD, IRIS M IV) and atmospheric measurements were carried out in order to provide data for optical sensor calibration. Ground spectrometry measurements were carried out in the runway area of the DLR research center Oberpfaffenhofen. This area was used as well during the GER 2 European flight campaign EISAC 89 as a calibration target. The land application testsite Oberpfaffenhofen is located 3 km north of the DLR research center. During the MAC Europe 91 Campaign a ground survey was carried out for documentation in the ground information data base (vegetation type, vegetation geometry, soil type, and soil mixture). Crop stands analyzed were corn, barley and rape. The DLR runway area and the land application testsite Oberpfaffenhofen were flown with the AVIRIS on 29 July and with the GER 2 on 12 and 23 July and 3 Sep. AVIRIS and GER 2 scenes were processed and atmospherically corrected for optical data analysis of optical and radar data. For the AVIRIS and the GER 2 scenes, signal-to-noise ratios (SNR) estimates were calculated. An example of the reflectance of 6 calibration targets inside a GER 2 scene of Oberpfaffenhofen is given. SNR values for the GER 2 for a medium albedo target are given. The integrated analysis for the optical and radar data was carried out in cooperation with the DLR Institute for Microwave Technologies.

Lehmann, F.

Pulling-Speed Control for Silicon-Web Growth

Proposed control system for dendritic-web growth of silicon ribbons varies ribbon speed according to melt temperature. System prevents too fast or too slow withdrawal of silicon web, which cause pullout of web or excessive web thickness, respectively. System also enables semiautomatic startup of web growth by automatically increasing web speed from zero to optimum value.

Richter, R.

Centrally-Rupturing Squib-Closure Disks

Rupture-disk design makes squib action more predictable. In new design, center of rupture disk contains cruciform indentation in which thickness reduced to about 0.5 mil (0.013 mm). Reduces strength of center of rupture disk in same manner as that of pull tabs on beverage cans; therefore, disk will fail predictably in center.

Richter, R.

Faster Edge-Define Silicon-Ribbon Growth

End-cooling allows faster growth and yields single-crystal ribbons. Improvement in edge-defined film-fed process for growing silicon ribbons increases speed of growth and improves quality of silicon product. Also produces silicon sheets, webs, or boules. Cold shoes cool melt at ends of emerging sheet. Since solidification at ends now occurs before end menisci reach maximum height, ribbon drawn substantially faster.

Richter, R.

Crystal-Growing Crucible To Suppress Convection

Platform under growth region stabilizes melt for more uniform crystal growth. In new crucible, platform just below growth interface so melt is too shallow to support convection. Critical depth for onset of pertinent instability calculated from heat flux through surface of melt, volume coefficient of thermal expansion, thermal conductivity, thermal diffusivity, and kinematic viscosity.

Richter, R.

Thermally-Rechargeable Electrochemical Cell

Proposed liquid-sodium/sulfur electrochemical cell recharged by heat, rather than electric generator. Concept suitable for energy storage for utilites, mobile electronic equipment, and solar thermoelectric power systems. Sodium ions driven across membrane with aid of temperature differential.

Richter, R.

Silicon dendritic web growth thermal analysis task

A thermal analysis model is presented which describes the dendritic ribbon process. The model uses a melt-dendrite interface which projects out of the bulk melt as the basic interpretation of the ribbon production process. This is a marked departure from the interpretations of the interface phenomena which were used previously. The model was extensively illustrated with diagrams and pictures of ribbon samples. This model should have great impact on the analyses of experimental data as well as on future design modifications of ribbon-pulling equipment.

Richter, R.

Measuring Absolute Oxygen Pressure

Sensor determines absolute pressure of oxygen without reference pressure source. Absolute oxygen pressure transducer with control circuit enables measurement without reference pressure. Transducer, two part device, combines solid electrolyte membranes sensor with diffusional orifice. Device adapted for direct control of oxygen pressure in combustion mixtures.

Richter, R.

Sealing Mechanical Cryogenic Coolers

Metal bellows used to seal Vuilleumier and Stirling-cycle cryogenic coolers, replacing sliding seals that failed after only 3,000 hours of service. Metal bellows, incorporated in displacer design provide nonrubbing dynamic seal. Lifetime of cryogenic cooler no longer limited by loss of sealing material and by deterioration of regenerators due to clogging by seal debris.

Richter, R.

Oxidation Protection for Thermocouples

Thin platinum film on thermocouple sheath protects non-noble-metal thermocouples from deterioration in oxygen-rich atmosphere. Coating works on nickel-alloy sheathed thermocouples otherwise destroyed by corrosion in pure oxygen at 1,000 degrees C.

Richter, R.

Ion Engine With Solid-Electrolyte Ion Generator

Working fluid utilized efficiently. Working fluid positive ions conducted through solid electrolyte to outside, then accelerated in external electric field. While in solid-electrolyte material, ions do not recombine with electrons: transported to surface with high ionization efficiency. Provides new way to generate beam of ions for implantation in semiconductors or other applications.

Richter, R.

Ionic Refrigerator

With no moving parts, proposed refrigerator has long life. Thermal energy of refrigeration process transported by hydrogen ions that go through three phase changes in absorbing heat and three phase changes in dissipating heat.

Richter, R.

Improved Gas Seal for Electrolytic Cells

Breakage by differential thermal expansion reduced. Cells for hot electrolysis of gases improved by design that reduces vulnerability of gas seals to breakage at operating temperature of about 1000 degrees C.

Richter, R.

Evaluation of aperture cover tank vent nozzles for the IRAS spacecraft

The influence of coefficients for the three axes of the Infrared Astronomical Satellite (IRAS) were established to determine the maximum allowable thrust difference between the two vent nozzles of the aperture cover tank low thrust vent system and their maximum misalignment. Test data generated by flow and torque measurements permitted the selection of two nozzles whose thrust differential was within the limit of the attitude control capability. Based on thrust stand data, a thrust vector misalignment was indicated that was slightly higher than permissible for the worst case, i.e., considerable degradation of the torque capacity of the attitude control system combined with venting of helium at its upper limit. The probability of destabilizing the IRAS spacecraft by activating the venting system appeared to be very low. The selection and mounting of the nozzles have satisfied all the requirements for the safe venting of helium.

Richter, R.

Striped Electrodes for Solid-Electrolyte Cells

Striped thick-film platinum electrodes help insure lower overall cell resistance by permitting free flow of gases in gaps between stripes. Thickfilm stripes are also easier to fabricate than porous thin-film electrodes that cover entire surface. Possible applications for improved cells include oxygen production from carbon dioxide, extraction of oxygen from air, small fluidic pumping, sewage treatment, and fuel cells.

Richter, R.

Integrated Solid-Electrolyte Construction

Proposed construction method for electrolytic cells would integrate porous surface electrodes into a block of solid electrolyte. Porous electrodes would facilitate unrestricted gas flow thereby improving cell performance. Electrode wire mesh is embedded at surface of solid electrolyte. Construction would assure high electrode conductance and low resistance to gas flow.

Richter, R.

Autonomous oxygen production for a Mars return vehicle

The way in which a chemical processor that uses the Martian atmosphere as its only feedstock, thereby reducing the mass that must be launched from earth, can help to return a surface sample from Mars from a single Space Shuttle launch is described. Richter's (1981) study on both the theoretical and experimental aspects of oxygen separation using yttria-stabilized zirconia membranes is cited. Here, separation is accomplished by applying a voltage across the membrane which results in the selective conduction of oxygen ions from one side to the other. It is noted that by using thermal dissociation of the carbon dioxide in the Martian atmosphere to produce oxygen (and carbon monoxide), these zirconia electrolytic cells can be employed to separate oxygen from the atmospheric stream. Descriptions are also given of atmospheric filtration, atmospheric compression, and waste heat recovery, and of the oxygen precooler and oxygen compressor.

Ash, R. L.

Basic investigation into the electrical performance of solid electrolyte membranes

The electrical performance of solid electrolyte membranes was investigated analytically and the results were compared with experimental data. It is concluded that in devices that are used for pumping oxygen the major power losses have to be attributed to the thin film electrodes. Relations were developed by which the effectiveness of tubular solid electrolyte membranes can be determined and the optimum length evaluated. The observed failure of solid electrolyte tube membranes in very localized areas is explained by the highly non-uniform current distribution in the membranes. The analysis points to a possible contact resistance between the electrodes and the solid electrolyte material. This possible contact resistance remains to be investigated experimentally. It is concluded that film electrodes are not appropriate for devices which operate with current flow, i.e., pumps though they can be employed without reservation in devices that measure oxygen pressures if a limited increase in the response time can be tolerated.

Richter, R.