Search NASA⌕ Search

Engineering topics

Rickman, John M.

Publications and source records attributed to Rickman, John M..

Mammalian complex III heme dynamics studied with pump-probe spectroscopy and red light illuminations

The electronic or molecular mechanisms which initiate photobiomodulation (PBM) in cells are not yet fully understood. Porcine complex III (C-III) of the electron transport chain was characterized with transient absorption spectroscopy (TAS). Then we applied our recently developed continuous wave laser coupled TAS procedure (CW-TAS) to investigate the effect of red light irradiances on the heme dynamics of C-III in its c 1 reduced state. The time constants associated with the axial ligand photodissociation were found to be 3.3 ± 0.3 ps for the oxidized state and 4.9 ± 0.4 ps for the c 1 reduced state. The analysis of the CW-TAS procedure yielded no significant changes in the C-III heme dynamics. We rule out the possibility of 635 nm CW light at 4.7 mW/cm 2 inducing a PBM effect on the heme dynamic of C-III, specifically with the photodissociation of its axial ligand.

59 BASIC BIOLOGICAL SCIENCES↗

Transient absorption spectroscopy to explore cellular pathways to photobiomodulation

Photobiomodulation (PBM) describes the use of low irradiance light in the red to near-infrared wavelength range to stimulate biological effects in tissue, and many biological and spectroscopic techniques are used to study PBM. However, these techniques focus on the products or downstream effects rather than the electronic transitions that initiate the PBM processes. This study presents a novel approach to studying low irradiance light exposures on individual proteins and/or protein complexes by combining a continuous wave (CW) laser diode with femtosecond transient absorption spectroscopy (TAS), coined here as CW-TAS, and tests the system on reduced cytochrome c (Cyt c) for proof of principle. TAS was conducted using a 532-nm excitation pump beam and a 350-600 nm supercontinuum probe. In this work, CW laser diodes with wavelengths of 450 nm, 635 nm, and 808 nm were interchangeably fiber coupled into the HELIOS Fire. Samples of Cyt c were tested by TAS using a pump power of 15 µW, both with and without CW exposure. CW exposures were carried out with irradiances of 1.60 and 3.20 mW/cm 2 , except for 808 nm, which was only tested at 1.60 mW/cm 2 . Both kinetic and global analyses were performed on the TAS data and the time constants for sets with and without CW exposures were compared. The TAS data for Cyt c with the full dosage of CW exposures did not alter the TAS data distinguishably from the control data. No new electronic transient signals were observed beyond the background when testing Cyt c with the CW exposures. Kinetic analysis confirmed that existing transients did not deviate beyond uncertainty. Global time constants for Cyt c were calculated to be 0.25 ± 0.03 ps and 5.1 ± 0.3 ps for the control study, and the time constants for the CW exposed Cyt c were not significantly different. This study concludes that CW irradiation, at doses delivered, does not alter the transient absorption data of Cyt c. The CW-TAS method provides a new tool for studying PBM effects in other proteins and protein complexes, such as Complex IV, in future studies.

59 BASIC BIOLOGICAL SCIENCES↗