Guest Editorial: Special section on Resilient Control of Cyber-Physical Power and Energy Systems

Our power and energy systems are becoming more and more integrated and interconnected. The increasing integration of edge devices and dependence on cyber infrastructure provides both the potential for benefits and risks. The integration enables more dynamic and flexible control paradigms while at the same time increasing the cyberattack surface and uncertainty of behavior. Control methodology in this new world must be designed for resilience and must have the ability to withstand, react, and respond to both physical faults and cyber-induced threats. Finally, understanding system resilience under adverse conditions requires studying control performance and how cyber infrastructure can integrate with and support the overall resilience of the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cy-Phy ADS: Cyber Physical Anomaly Detection Framework for EV Charging Systems

Today’s large-scale Electric Vehicle (EV) infrastructures are heavily dependent on information communication technologies to maintain their operation and to support communication within sub-system components as well as the outside world. These technologies are vulnerable to various cyber and physical threats. Timely identification and mitigation of these threats are critical for improving human safety, avoiding economic losses, and preventing catastrophic system failures. By addressing this, our work presents a ResNet Autoencoder (AE) based Cyber-Physical Anomaly Detection System (Cy-Phy ADS) for detecting anomalies in EV Controller Area Network (CAN) protocol communication. It consists of four main components: Cyber-Physical Feature Extractor, ResNet AE-based Anomaly Detection Framework, Cyber-Physical Health Metric (CPHM), and Visualization Dashboard. The presented framework was trained and tested using CAN data collected from the EV charging system testbed at the Idaho National Laboratory. The presented Cy-Phy ADS compared against six widely used unsupervised anomaly detection algorithms: One Class Support Vector Machine (OCSVM), Variational Autoencoder (VAE), LSTM Autoencoder (LSTM AE), Isolation Forest (IForest), Principle Component Analysis (PCA) and Local Outlier Factor (LOF). Here the presented approach showed the highest accuracy among the compared methods. Further, the proposed approach showed comparable performance in terms of precision, F1, and False positive rate. It also showed the lowest training and inference time compared to the neural network-based baseline algorithms compared against with. Additionally, the Cy-Phy ADS has advantages such as unsupervised training, the ability to provide a holistic metric for system health characterization, and non-linear feature extraction.

99 GENERAL AND MISCELLANEOUS↗

Improving Resiliency for Electric Vehicle Charging

Electric vehicles are seeing growing adoption. However, challenges with range anxiety persists. While charging infrastructure is anticipated to expand, EV charger systems have not been as robust to challenges. This paper discusses potential outage conditions associated with EV charging and presents new technology in development to improve EV charging resilience.

Electric vehicle charging, electric vehicle chargi↗

A Review of Visualization Methods for Cyber-Physical Security: Smart Grid Case Study

Cyber-Physical Systems (CPSs) are becoming increasingly complex and interconnected as they attempt to meet the demands of evolving society. As a result, monitoring and maintaining them becomes a more complex and demanding task for control system operators and cyber defenders. While the literature on visualization techniques in the context of cybersecurity is extensive, the same cannot be said for studies on visualization for the security of cyber-physical systems. This paper aims to fill that gap by: 1) defining the main features of a visualizations workflow for security visualizations in cyber-physical systems. The workflow includes the acquisition of cyber and physical data, processing of data, selection, and configuration of both visualization tools and end-user interactions. 2) Providing an overview of cyber-physical security visualization systems, with a focus on smart grids as a case study. Finally, we use the perspectives gained from this analysis to provide insights and directions for future research and design of cyber-physical visualization techniques.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MIRACL Co-Simulation Platform Lab assets and tools integration

Pacific Northwest National Laboratory's (PNNL) co-simulation platform (CSP) for the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) project, also known as MIRACL-CSP, is a functional layer designed and developed to oversee the operational exchanges of data at the application level to and from different resources residing on the MIRACL Data Hub shared platform. MIRACL-CSP allows virtual interactions between various data hub resources during co-simulation runtime.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilience of electric utilities during the COVID-19 pandemic in the framework of the CIGRE definition of Power System Resilience

Resilience is a vital concept in engineering, business, and natural sciences, and is a measure of the ability of an entity to withstand High Impact Low Probability (HILP) events. During the COVID-19 pandemic, which started in late 2019/early 2020, power system utilities around the globe have responded in effective and efficient ways to enhance the resilience of their organisations, both in terms of real-time operations and prudent management of its infrastructure, in order to continue their mandate in providing reliable supply to meet customer demands. Here, this paper presents the CIGRE definition for power system resilience, established by the C4.47 Working Group in 2018, and demonstrates the application of resilience-oriented thinking within the electrical sector. The response and recovery efforts are described, with respect to the key actionable measures integral to the power system resilience definition, taken before, during and after the COVID-19 pandemic. A practical conceptual framework is also presented for thinking about resilience in terms of three key components of resilience strategies: organisational, infrastructure and operational resilience. The paper also discusses the different strategies adopted in response to COVID-19, based on the C4.47 members’ experiences during the pandemic. Finally, a case study is presented, which proves the effectiveness of a set of response measures, using graph theory and the characteristics of the staff-asset interactions.

42 ENGINEERING↗

Concept for Cyber-Physical Consequence Process

The Department of Homeland Security’s Office of Cyber and Infrastructure Analysis (DHS/OCIA) has a mission and vision that promotes innovation as central to expanding the organization’s capability to conduct consequence analysis. To pursue such innovation, OCIA is sponsoring a seedling effort with Idaho National Laboratory (INL) to leverage data from the proposed Automated Vulnerability Assessment (AVA) capability, which the DHS Science and Technology (S&T) Directorate is developing through a separate INL effort. The first phase of this effort is to develop a process by which recognized vulnerabilities can be scored relative to importance, reflected primarily in the ability to initiate high consequence and potentially cascading events. This report documents a cyber-physical metrics process (CPMP) to tie physical impact to the malicious exploitation of cyber vulnerabilities in industrial control systems (ICS) with the potential for initiating consequence in the critical infrastructure. The scale of achieving any particular physical consequence is dependent upon the ICS Component the vulnerability exists on, the Level of Access that the exploit would allow to component function and the Physical Impact (CLAPI) to the power system that the component is tied. A modified common vulnerability scoring system (CVSS) was detailed and demonstrated for the power sector with three case studies associated with a recognized vulnerability, with significant consequence detail provided to apply the process across the power sector. A detailed table that provides background on the power system components, ICS-enabled monitoring and control, potential consequence effects, and CVSS scoring is provided. To demonstrate the applicability of the CPMP, tables are provided as examples for other sectors that include chemical, water/wastewater and oil/gas.

42 ENGINEERING↗

FN-DFE: Fuzzy-Neural Data Fusion Engine for Enhanced State-Awareness of Resilient Hybrid Energy System

Resiliency and improved state-awareness of modern critical infrastructures, such as energy production and industrial systems, is becoming increasingly important. As control systems become increasingly complex, the number of inputs and outputs increase. Therefore, in order to maintain sufficient levels of state-awareness, a robust system state monitoring must be implemented that correctly identifies system behavior even when one or more sensors are faulty. Furthermore, as intelligent cyber adversaries become more capable, incorrect values may be fed to the operators. To address these needs, this paper proposes a Fuzzy-Neural Data Fusion Engine (FN-DFE) for resilient state-awareness of control systems. The designed FN-DFE is composed of a three-layered system consisting of: 1) traditional threshold based alarms, 2) anomalous behavior detector using self-organizing fuzzy logic system, and 3) artificial neural network based system modeling and prediction. The improved control system state-awareness is achieved via fusing input data from multiple sources and combining them into robust anomaly indicators. In addition, the neural network based signal predictions are used to augment the resiliency of the system and provide coherent state-awareness despite temporary unavailability of sensory data. The proposed system was integrated and tested with a model of the Idaho National Laboratory’s (INL) hybrid energy system facility know as HYTEST. Experimental results demonstrate that the proposed FN-DFE provides timely plant performance monitoring and anomaly detection capabilities. It was shown that the system is capable of identifying intrusive behavior significantly earlier than conventional threshold based alarm systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Mining Building Energy Management System Data Using Fuzzy Anomaly Detection and Linguistic Descriptions

Building Energy Management Systems (BEMSs) are essential components of modern buildings that utilize digital control technologies to minimize energy consumption while maintaining high levels of occupant comfort. However, BEMSs can only achieve these energy savings when properly tuned and controlled. Since indoor environment is dependent on uncertain criteria such as weather, occupancy, and thermal state, performance of BEMS can be sub-optimal at times. Unfortunately, the complexity of BEMS control mechanism, the large amount of data available and inter-relations between the data can make identifying these sub-optimal behaviors difficult. This paper proposes a novel Fuzzy Anomaly Detection and Linguistic Description (Fuzzy-ADLD) based method for improving the understandability of BEMS behavior for improved state-awareness. The presented method is composed of two main parts: 1) detection of anomalous BEMS behavior and 2) linguistic representation of BEMS behavior. The first part utilizes modified nearest neighbor clustering algorithm and fuzzy logic rule extraction technique to build a model of normal BEMS behavior. The second part of the presented method computes the most relevant linguistic description of the identified anomalies. The presented Fuzzy-ADLD method was applied to real-world BEMS system and compared against a traditional alarm based BEMS. In six different scenarios, the Fuzzy-ADLD method identified anomalous behavior either as fast as or faster (an hour or more), that the alarm based BEMS. In addition, the Fuzzy-ADLD method identified cases that were missed by the alarm based system, demonstrating potential for increased state-awareness of abnormal building behavior.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fujitsu and BEA Collaboration on Cyber Enabled Smart Grid Performance (CRADA Final report)

In conclusion of this CRADA, this letter documents the actions taken in regard to this collaboration. While the statement of work overviews several joint tasks associated with this effort, the availability of resources on the FLA side prevented any collaboratory development of shared Intellectual Property. Therefore, no patents, copyrights or publications resulted from this effort. However, several meetings at the INL and FLA offices maintained a good relationship and sharing of other potential areas of collaboration in the area of building/community energy management and cyber security.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Revealing Occupancy Patterns in an Office Building through the Use of Occupancy Sensor Data

Energy simulation programs like DOE-2 and EnergyPlus are tools that have been proven to aid with energy calculations to predict energy use in buildings. Some inputs to energy simulation models are relatively easy to find, including building size, orientation, construction materials, and HVAC system size and type. Others vary with time (e.g. weather and occupancy) and some can be a challenge to estimate in order to create an accurate simulation. In this paper, the analysis of occupancy sensor data for a large commercial, multi-tenant office building is presented. It details occupancy diversity factors for private offices and summarizes the same for open offices, hallways, conference rooms, break rooms, and restrooms in order to better inform energy simulation parameters. Long-term data were collected allowing results to be presented to show variations of occupancy diversity factors in private offices for time of day, day of the week, holidays, and month of the year. The diversity factors presented differ as much as 46% from those currently published in ASHRAE 90.1 2004 energy cost method guidelines, a document referenced by energy modelers regarding occupancy diversity factors for simulations. This may result in misleading simulation results and may introduce inefficiencies in the final equipment and systems design.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

UNDERSTANDING FLOW OF ENERGY IN BUILDINGS USING MODAL ANALYSIS METHODOLOGY

It is widely understood that energy storage is the key to integrating variable generators into the grid. It has been proposed that the thermal mass of buildings could be used as a distributed energy storage solution and several researchers are making headway in this problem. However, the inability to easily determine the magnitude of the building’s effective thermal mass, and how the heating ventilation and air conditioning (HVAC) system exchanges thermal energy with it, is a significant challenge to designing systems which utilize this storage mechanism. In this paper we adapt modal analysis methods used in mechanical structures to identify the primary modes of energy transfer among thermal masses in a building. The paper describes the technique using data from an idealized building model. The approach is successfully applied to actual temperature data from a commercial building in downtown Boise, Idaho.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Revealing Occupancy Patterns in Office Buildings Through the use of Annual Occupancy Sensor Data

Energy simulation programs like DOE-2 and EnergyPlus are tools that have been proven to aid with energy calculations to predict energy use in buildings. Some inputs to energy simulation models are relatively easy to find, including building size, orientation, construction materials, and HVAC system size and type. Others vary with time (e.g. weather and occupancy) and some can be a challenge to estimate in order to create an accurate simulation. In this paper, the analysis of occupancy sensor data for a large commercial, multi-tenant office building is presented. It details occupancy diversity factors for private offices and summarizes the same for open offices, hallways, conference rooms, break rooms, and restrooms in order to better inform energy simulation parameters. Long-term data were collected allowing results to be presented to show variations of occupancy diversity factors in private offices for time of day, day of the week, holidays, and month of the year. The diversity factors presented differ as much as 46% from those currently published in ASHRAE 90.1 2004 energy cost method guidelines, a document referenced by energy modelers regarding occupancy diversity factors for simulations. This may result in misleading simulation results and may introduce inefficiencies in the final equipment and systems design.

47 OTHER INSTRUMENTATION↗