Initial Super-Nyquist Wavefront Control Experiments in the Decadal Survey Testbed
No abstract provided
Engineering topics
Publications and source records attributed to Riggs, A J Eldorado.
No abstract provided
No abstract provided
Coronagraph instruments rely on predictable and stable deformable mirror (DM) surface displacement to achieve the contrast required to detect Earth-sized exoplanets orbiting nearby Solar-type stars. Anomalous DM behavior, such as unstable or pinned actuators, can limit contrast in coronagraphs. Simulating how these undesired behaviors affect the performance of a high contrast imaging architecture is important for developing requirements on their associated hardware. Simulating a vortex coronagraph (VC) with two deformable mirrors, this study quantifies how the number of pinned actuators affect the performance of Focal Plane Wavefront Sensing and Control algorithms using both Grid Search Electric Field Conjugation (EFC) and Planned EFC, which uses Beta-Bumping. The simulation also quantifies how various types of voltage noise such as zero-mean Gaussian noise, zero-mean periodic noise, and drift can affect the contrast of a VC during an observation run. A tolerance of a change in the Mean Normalized Intensity of ${1\times10^{-11}}$ is allocated to both types of error. If Planned EFC is used, only 1 pinned actuator on both DMs can be tolerated. If only pure Grid Search EFC is used the DMs cannot have any pinned actuators. For the case of zero-mean Gaussian noise and zero-mean periodic noise, one can tolerate a noise standard deviation of no more than ${\sigma = 0.45 \text{ mV}}$. For drift, we can only tolerate ${\sigma = 0.30 \text{ mV}}$ or less. These results show that the DM electronics and the DM themselves need to be nearly defect free to avoid having more than 1 pinned actuator. The electronics need to be tested for different types of noise statistics and that both the average and standard deviation of the noise should be measured.
We have developed the Fast Linearized Coronagraph Optimizer (FALCO), a new software toolbox for high-contrast, coronagraphic wavefront sensing and control. FALCO rapidly calculates the linearized deformable mirror (DM) response matrices, also called control Jacobians, and can be used for the design, simulation, or testbed operation of several types of coronagraphs. In this paper, we demonstrate that the optical propagation used in FALCO is accurate and matches PROPER. In addition, we demonstrate the drastic reduction in runtime when using FALCO for DM Jacobian calculations instead of the conventional method used, for example with a model of the Wide-Field Infrared Survey Telescope (WFIRST) Coronagraph Instrument (CGI). We then compare the relative accuracy between optical models in FALCO and PROPER.
NASA's WFIRST Coronagraph Instrument (CGI) is planned to image and characterize exoplanets at high contrast. The CGI operating modes are the hybrid Lyot coronagraph for planet detection and inner debris disk imaging, a shaped pupil coronagraph for planet characterization, and another shaped pupil for outer disk imaging. Early CGI designs focused on overcoming the di raction of the large pupil obscurations. Now that those designs have been proven to work in the lab, the design emphasis has been on achieving higher throughput and lower sensitivities to jitter and polarization aberrations. Here we present those improvements and the integration of science yield modeling into the spectrographic shaped pupil design process.