Engineering topics
Rimmer, Robert A.
Publications and source records attributed to Rimmer, Robert A..
A High Power Prototype of a Harmonic Kicker Cavity
A harmonic kicker, a beam exchange device that can deflect the beam at an ultra-fast time scale (a few ns), has been developed in Jefferson Lab *, **. The high power prototype that can deliver more than a 100 kV kick at 7 kW was fabricated. The RF performance of cavity such as the harmonic resonant frequencies, kick profiles, it’s stability, and electric center is tested at bench. The cavity will eventually be tested with a beam at Upgraded Injector Test Facility (UITF) in Jefferson Lab. In this paper, we report some features of fabrication and bench test results. We also briefly describe our beam test plan in the future.
ELECTRON COOLING USING A PULSED AND DITHERING BEAM FROM AN ELECTROSTATIC ELECTRON COOLER
Electron cooling continues to be an invaluable technique to reduce and maintain the emittance in hadron storage rings such as the EIC and EICC where stochastic cooling is inefficient and radiative cooling is negligible. Extending the energy range of electron coolers beyond what is feasible with the conventional, electrostatic approach necessitates the use of RF fields for acceleration and, thus, a bunched electron beam. To experimentally investigate how the relative time structure of the two beams affects the cooling properties, we have set up a pulsed-beam cooling device by adding a synchronized pulsing circuit to the conventional electron source of the CSRm cooler at Institute of Modern Physics. Using both constant and modulated synchronization between electron pulses and ion bunches, we have measured the effects of the electron bunch length and longitudinal ion focusing strength on the temporal evolution of the longitudinal and transverse ion beam profile and demonstrated the detrimental effect of timing jitter as predicted by space-charge theory and simulations. Our experiment suggests a need for further investigations of specific aspects of bunched cooling such as synchro-betatron coupling and phase dithering effects when using short electron bunches to cool longer ion bunches. However, given the comparatively long IBS lifetime of higher-energy proton storage rings like the EIC, slow dithering could potentially provide an option to save cost on the electron cooler linac.
Beam exchange of a circulator cooler ring with an ultrafast harmonic kicker
Not Available
Multi-metallic conduction cooled superconducting radio-frequency cavity with high thermal stability
Superconducting radio-frequency cavities are commonly used in modern particle accelerators for applied and fundamental research. Such cavities are typically made of high-purity, bulk Nb and with cooling by a liquid helium bath at a temperature of ~2 K. The size, cost and complexity of operating a particle accelerator with a liquid helium refrigerator make the current cavity technology not favorable for use in industrial-type accelerators. We have developed a multi-metallic 1.495 GHz elliptical cavity conductively cooled by a cryocooler. The cavity has a ~2 µm thick layer of Nb 3 Sn on the inner surface, exposed to the rf field, deposited on a ~3 mm thick bulk Nb shell and a bulk Cu shell, of thickness $\geqslant\! 5$ mm deposited on the outer surface by electroplating. A bolt-on Cu plate 1.27 cm thick was used to thermally connect the cavity equator to the second stage of a Gifford-McMahon cryocooler with a nominal capacity of 2 W at 4.2 K. The cavity was tested initially in liquid helium at 4.3 K and reached a peak surface magnetic field of ~36 mT with a quality factor of 2 × 10 9 . The cavity cooled by the cryocooler achieved a peak surface magnetic field of ~29 mT, equivalent to an accelerating gradient of 6.5 MV m –1 . The conduction-cooled cavity could be operated in continuous-wave with as high as 5 W dissipation in the cavity for 1 h without any thermal breakdown, because of the Cu outer layer with high thermal conductivity. This result represents a paradigm shift in the technology of superconducting accelerator cavities.
Using a TE011 Cavity as a Magnetic Momentum Monitor
The Jefferson Lab Electron-Ion Collider (JLEIC) design relies on cooling of the ion beam with bunched electron beam constrained in a pair of long solenoids. The high current cooling electron beam needs to be generated in a magnetized electron source, and the beam's magnetization needs to be maintained during the acceleration and transport to the cooling channel. A non-invasive real time monitoring system is highly desired to quantify electron beam magnetization. The authors propose to use a passive copper RF cavity in TE011 mode as such a monitor. In this paper, we present the mechanism and scaling law of this device, as well as the design and preliminary test results of the prototype cavity.
952.6 MHz SRF cavity development for JLEIC
JLab is developing new SRF cavity designs at 952.6 MHz for the proposed Jefferson Lab Electron-Ion Collider (JLEIC). New cavities will be required for the ion ring, cooler ERL and booster and eventually for the electron ring to allow the highest possible bunch collision rate. The challenges include the need for strong HOM damping, high fundamental mode power couplers and high HOM power. Initial focus is on the cooler ERL five- cell cavity as this is a critical component for the strong, high energy, bunched-beam cooling concept. One-cell and five-cell Nb prototype cavities have been designed and fabricated. Details concerning the cavity fabrication and test results for the will be presented.
Development of a bunched beam electron cooler for the Jefferson Lab electron-ion collider
Jefferson Lab is in the process of designing an electron-ion collider with unprecedented luminosity at a 65 GeV center-of-mass energy. This luminosity relies on ion cooling in both the booster and the storage ring of the accelerator complex. The cooling in the booster will use a conventional DC cooler similar to the one at COSY. The high-energy storage ring, operating at a momentum of up to 100 GeV/nucleon, requires novel use of bunched-beam cooling. We will present a new design for a Circulator Cooler Ring for bunched-beam electron cooling. This requires the generation and transport of very high-charge magnetized bunches, acceleration of the bunches in an energy recovery linac, and transfer of these bunches to a circulating ring that passes the bunches 11 times through the proton or ion beam inside cooling solenoids. This design requires the suppression of the effects of space charge and coherent synchrotron radiation using shielding and RF compensation.
Commissioning of the prototype C75 cavities in a CEBAF cryomodule
Prototype cavities have been built at Jefferson Lab to increase the energy of future refurbished CEBAF cryomodules to 75 MeV in the most cost efficient way. Three such cavities, named "C75", have been built from ingot Nb material of different purity and have been processed and tested. The two better performing cavities have been assembled into a "cavity pair" and installed in the latest refurbished original CEBAF cryomodule. The cryomodule was installed and commissioned in CEBAF. The results from the commissioning of the C75 cavities, compared with the original CEBAF cavities, are presented in this article. The vertical test performance of the C75 cavities was preserved in the cryomodule with one of the cavities achieving the performance specification of an accelerating gradient of 19 MV/m with a quality factor of ~8×109 at 2.07 K. The performance in terms of microphonics and tuner operation was similar to that of original CEBAF cavities, as expected, and the high-order modes are properly damped. The quality factor of the two C75 cavities was the highest achieved in a CEBAF cryomodule, possibly due to the better magnetic flux expulsion of ingot Nb than standard fine-grain Nb.
Magnetron R&D toward the Amplitude Modulation Control for SRF Accelerator
The scheme of using a high efficiency magnetron to drive a superconducting radio frequency (SRF) accelerator cavity needs not only the injection phase locking but also the amplitude modulation to compensate the cavity's microphomics caused cavity voltage change and the beam loading variation. To be able to do a fast and efficient modulation, the magnetron's magnetic field has to be trimmed by an external coil to compensate the frequency pushing effect due to the anode current change [1]. A low eddy current magnetron body has been designed and built [2]. This paper will present the analytical prediction, simulation and experimental results on the 2.45 GHz magnetron test stand with the modulation frequency up to 1 kHz. In addition, the progresses on the injection lock to a copper cavity, new 1497 MHz magnetron prototype, 13 kW high power magnetron test stand development and newly built low level RF (LLRF) controller for the amplitude modulation will be reported.
802 MHz ERL Cavity Design and Development
In the framework of a collaboration between CERN and JLab, an SRF accelerating cavity for energy recovery linacs operating at 802 MHz was developed in the context of the CERN's Large Hadron electron Collider (LHeC) design study. A single-cell and a five-cell cavity from fine grain high RRR niobium were built at JLab to validate the basic RF design in vertical tests. Two copper single-cell cavities were produced in parallel for R&D purposes at CERN. The cavity design has since been adapted as baseline for the main linac cavities in the proposed Powerful Energy Recovery Linac Experiment facility (PERLE) at Orsay. Details concerning the cavity fabrication and test results for the Nb cavities are presented.
PERLE - Lattice Design and Beam Dynamics Studies
PERLE (Powerful ERL for Experiments) is a novel ERL test facility, initially proposed to validate choices for a 60 GeV ERL foreseen in the design of the LHeC and the FCC-eh. Its main thrust is to probe high current, CW, multi-pass operation with superconducting cavities at 802 MHz (and perhaps testing other frequencies of interest). With very high virtual beam power (~ 10 MW), PERLE offers an opportunity for controllable study of every beam dynamic effect of interest in the next generation of ERL design; becoming a ‘stepping stone' between present state-of-art 1 MW ERLs and future 100 MW scale applications. PERLE design features Flexible Momentum Compaction lattice architecture for six vertically stacked return arcs and a high-current, 6 MeV, photo-injector. With only one pair of 4 cavity cryomodules, 400 MeV beam energy can be reached in 3 re-circulation passes, with beam currents in excess of 15 mA. The beam is decelerated in 3 consecutive passes back to the injection energy, transferring virtually stored energy back to the RF. This unique facility will serve as a test-bed for high current ERL technologies, as well as a user facility in low energy electron and photon physics.
A Non-destructive Magnetic Momentum Monitor Using a TE011 Cavity
The Jefferson Lab Electron-Ion Collider (JLEIC) design relies on cooling of the ion beam with bunched electron beam. The bunched beam cooler complex consists of a high current magnetized electron source, an energy recovery linac, a circulating ring, and a pair of long solenoids where the cooling takes place. A non-invasive real time monitoring system is highly desired to quantify electron beam magnetization. The authors propose to use a passive copper RF cavity in TE011 mode as such a monitor. In this paper, we will show the mechanism and scaling law of this device, as well as the design and testing results of the prototype cavity.
Experimental Demonstration of Ion Beam Cooling with Pulsed Electron Beam
Cooling ion beams at high energy is presently considered for several ion colliders, in order to achieve high luminosities by enabling a significant reduction of emittance of hadron beams. Electron beam at cooling channel in a few to tens MeV can be accelerated by a RF/SRF linac, and thus using bunched electrons to cool bunched ions. To study such cooling process, the DC electron gun of EC35 cooler at the storage ring CSRm, IMP was modified by pulsing the grid voltage. A 0.07-3.5 micro-second pulse length with a repetition frequency of less than 250 kHz and synchronized with the ion revolution frequency was obtained. The first experimental demonstration of cooling of a coasting and bunched ion beam by a pulsed electron beam was carried out. Data analysis indicates the bunch length shrinkage and the momentum spread reduction of bunched 12C+6 ion beam as evidence of cooling. A longitudinal grouping effect of the coasting ion beam by the electron pulses has also been observed*. In this paper, we will present experimental results and comparison to the simulation modelling, particularly on the bunched electron cooling data after carefully analyzing the beam diagnostic signals.
The development of a new fast harmonic kicker for the JLEIC circulator cooler ring
After the first harmonic kicker cavity prototyping [1] for the JLEIC's CCR/ERL and the beam dynamic simulation study of the CCR [2], the CCR injection/extraction scheme has been changed to accommodate the various collision frequencies, requiring a new harmonic RF kicker system. The new kicker design, including the electromagnetic and beam dynamics simulation, is presented here.
Development of a Bunched Beam Electron Cooler based on ERL and Circulator Ring Technology for the Jefferson Lab Electron-Ion Collider
Jefferson Lab is in the process of designing an electron ion collider with unprecedented luminosity at a 45 GeV center-of-mass energy. This luminosity relies on ion cooling in both the booster and the storage ring of the accelerator complex. The cooling in the booster will use a conventional DC cooler similar to the one at COSY. The high-energy storage ring, operating at a momentum of up to 100 GeV/nucleon, requires novel use of bunched-beam cooling. There are two designs for such a cooler. The first uses a conventional Energy Recovery Linac (ERL) with a magnetized beam while the second uses a circulating ring to enhance both peak and average currents experienced by the ion beam. This presentation will describe the design of both the Circulator Cooling Ring (CCR) design and that of the backup option using the stand-alone ERL operated at lower charge but higher repetition rate than the ERL injector required by the CCR-based design.
Multiple harmonic frequencies resonant cavity design and half-scale prototype measurements for a fast kicker
Not Available