Demonstration of the HeRALD superfluid helium detector concept

The SPICE/HeRALD collaboration is performing research and development to enable studies of sub-GeV dark matter models using a variety of target materials. Here we report our recent progress on instrumenting a superfluid 4 He target mass with a transition-edge sensor based calorimeter to detect both atomic signals (scintillation) and 4 He quasiparticle (phonon and roton) excitations. The sensitivity of HeRALD to the critical “quantum evaporation” signal from 4 He quasiparticles requires us to block the superfluid film flow to the calorimeter. We have developed a heat-free film-blocking method employing an unoxidized Cs film, which we implemented in a prototype “HeRALD v0.1” detector of ~10 g target mass. This article reports initial studies of the atomic and quasiparticle signal channels. Here, a key result of this work is the measurement of the quantum evaporation channel’s gain of 0.15±0.01, which will enable 4 He-based dark matter experiments in the near term. With this gain the HeRALD detector reported here has an energy threshold of 145 eV at 5⁢σ, which would be sensitive to dark matter masses down to 220 MeV/c 2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear recoil response of liquid xenon and its impact on solar 8B neutrino and dark matter searches

Knowledge of the ionization and scintillation responses of liquid xenon (LXe) to nuclear recoils is crucial for LXe-based dark matter experiments. Current calibrations carry large uncertainties in the low-energy region below ∼3 keV nr where signals from dark matter particles of <10 GeV/c 2 masses are expected. The coherent elastic neutrino-nucleus scattering (CE ν NS) by solar 8 B neutrinos also results in a continuum of nuclear recoil events below 3.0 keV nr (99% of events), which further complicates low-mass dark matter searches in LXe experiments. In this paper, we describe a method to quantify the uncertainties of low-energy LXe responses using published calibration data, followed by case studies to evaluate the impact of yield uncertainties on 8 B searches and low-mass dark matter sensitivity in a typical ton-scale LXe experiment. We conclude that naively omitting yield uncertainties leads to overly optimistic limits by factor ∼2 for a 6 GeV WIMP mass. Future nuclear recoil light yield calibrations could allow experiments to recover this sensitivity and also improve the accuracy of solar 8 B flux measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fast and flexible analysis of direct dark matter search data with machine learning

We present the results from combining machine learning with the profile likelihood fit procedure, using data from the Large Underground Xenon (LUX) dark matter experiment. This approach demonstrates reduction in computation time by a factor of 30 when compared with the previous approach, without loss of performance on real data. We establish its flexibility to capture non-linear correlations between variables (such as smearing in light and charge signals due to position variation) by achieving equal performance using pulse areas with and without position-corrections applied. Its efficiency and scalability furthermore enables searching for dark matter using additional variables without significant computational burden. We demonstrate this by including a light signal pulse shape variable alongside more traditional inputs such as light and charge signal strengths. Furthermore, this technique can be exploited by future dark matter experiments to make use of additional information, reduce computational resources needed for signal searches and simulations, and make inclusion of physical nuisance parameters in fits tractable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effective field theory analysis of the first LUX dark matter search

The Large Underground Xenon (LUX) dark matter search was a 250-kg active mass dual-phase time projection chamber that operated by detecting light and ionization signals from particles incident on a xenon target. In December 2015, LUX reported a minimum 90% upper C.L. of 6 x 10 -46 cm 2 on the spin-independent WIMP-nucleon elastic scattering cross section based on a 1.4 x 10 4 kg ∙ day exposure in its first science run. Tension between experiments and the absence of a definitive positive detection suggest it would be prudent to search for WIMPs outside the standard spin-independent/spin-dependent paradigm. Recent theoretical work has identified a complete basis of 14 independent effective field theory (EFT) operators to describe WIMP-nucleon interactions. In addition to spin-independent and spin-dependent nuclear responses, these operators can produce novel responses such as angular-momentum-dependent and spin-orbit couplings. Here we report on a search for all 14 of these EFT couplings with data from LUX's first science run. Limits are placed on each coupling as a function of WIMP mass.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigating the XENON1T low-energy electronic recoil excess using NEST

The search for dark matter, the missing mass of the Universe, is one of the most active fields of study within particle physics. The XENON1T experiment recently observed a 3.5⁢𝜎 excess potentially consistent with dark matter, or with solar axions. Here, we will use the Noble Element Simulation Technique (NEST) software to simulate the XENON1T detector, reproducing the excess. We utilize different detector efficiency and energy reconstruction models, but they primarily impact sub-keV energies and cannot explain the XENON1T excess. However, using NEST, we can reproduce their excess in multiple, unique ways, most easily via the addition of 31 ± 11 37 Ar decays. Furthermore, this results in new, modified background models, reducing the significance of the excess to ≤2.2⁢𝜎 at least using non-Profile Likelihood Ratio (PLR) methods. This is independent confirmation that the excess is a real effect, but potentially explicable by known physics. Many cross-checks of our 37 Ar hypothesis are presented.

particle dark matter↗

Discrimination of electronic recoils from nuclear recoils in two-phase xenon time projection chambers

We present a comprehensive analysis of electronic recoil vs. nuclear recoil discrimination in liquid/gas xenon time projection chambers, using calibration data from the 2013 and 2014-16 runs of the Large Underground Xenon (LUX) experiment. We observe strong charge-to-light discrimination enhancement with increased event energy. For events with S1 = 120 detected photons, i.e. equivalent to a nuclear recoil energy of ~100 keV, we observe an electronic recoil background acceptance of <10 –5 at a nuclear recoil signal acceptance of 50%. We also observe modest electric field dependence of the discrimination power, which peaks at a field of around 300 V/cm over the range of fields explored in this study (50-500 V/cm). In the WIMP search region of S1 = 1-80 phd, the minimum electronic recoil leakage we observe is (7.3 ± 0.6) 10 –4 , which is obtained for a drift field of 240-290 V/cm. Pulse shape discrimination is utilized to improve our results, and we find that, at low energies and low fields, there is an additional reduction in background leakage by a factor of up to 3. We develop an empirical model for recombination fluctuations which, when used alongside the Noble Element Scintillation Technique (NEST) simulation package, correctly reproduces the skewness of the electronic recoil data. We use this updated simulation to study the width of the electronic recoil band, finding that its dominant contribution comes from electron-ion recombination fluctuations, followed in magnitude of contribution by fluctuations in the S1 signal, fluctuations in the S2 signal, and fluctuations in the total number of quanta produced for a given energy deposition.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved modeling of β electronic recoils in liquid xenon using LUX calibration data

We report here methods and techniques for creating and improving a model that reproduces the scintillation and ionization response of a dual-phase liquid and gaseous xenon time-projection chamber. Starting with the recent release of the Noble Element Simulation Technique (NEST v2.0), electronic recoil data from the $\beta$ decays of ${}^3$H and ${}^{14}$C in the Large Underground Xenon (LUX) detector were used to tune the model, in addition to external data sets that allow for extrapolation beyond the LUX data-taking conditions. This paper also presents techniques used for modeling complicated temporal and spatial detector pathologies that can adversely affect data using a simplified model framework. The methods outlined in this report show an example of the robust applications possible with NEST v2.0, while also providing the final electronic recoil model and detector parameters that will used in the new analysis package, the LUX Legacy Analysis Monte Carlo Application (LLAMA), for accurate reproduction of the LUX data. As accurate background reproduction is crucial for the success of rare-event searches, such as dark matter direct detection experiments, the techniques outlined here can be used in other single-phase and dual-phase xenon detectors to assist with accurate ER background reproduction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗