Engineering topics
Rivers, M L
Publications and source records attributed to Rivers, M L.
Using Synchrotron-based X-Ray Microtomography and Functional Contrast Agents in Environmental Applications
Abstract not provided
Can intra-aggregate pore structures affect the aggregate's effectiveness in protecting carbon?
Aggregates are known to provide physical protection to soil organic matter shielding it from rapid decomposition. Spatial arrangement and size distribution of intra-aggregate pores play an important role in this process. This study examined relationships between intra-aggregate pores measured using X-ray computed micro-tomography images and concentrations of total C in 4–6 mm macro-aggregates from two contrasting land use and management practices, namely, conventionally tilled and managed row crop agricultural system (CT) and native succession vegetation converted from tilled agricultural land in 1989 (NS). Previous analyses of these aggregates indicated that small (<15 μm) and large (>100 μm) pores prevail in NS aggregates while medium (30–90 μm) pores are more abundant in CT aggregates (Kravchenko et al., 2011; Wang et al., 2012). We hypothesized that these differences in pore size distributions affect the ability of macro-aggregates to protect C. The results of this study supported this hypothesis. Consistent with greater heterogeneity of pore distributions within NS aggregates we observed higher total C and greater intra-aggregate C variability in NS as compared with CT aggregates. Total C concentrations and intra-aggregate C standard deviations were negatively correlated with fractions of medium sized pores, indicating that presence of such pores was associated with lower but more homogeneously distributed total C. While total C was positively correlated with presence of small and large pores. The results suggest that because of their pore structure NS macro-aggregates provide more effective physical protection to C than CT aggregates.
An introduction to the application of X-ray microtomography to the three-dimensional study of igneous rocks
Imaging rocks in three-dimensions through X-ray microtomography enables routine visualization of structures in samples, which can be spatially resolved down to the sub-micron scale. Although X-ray tomography has been applied in biomedical research and clinical settings for decades, it has only recently been applied to studies of rocks, and few geoscientists realize its value and potential. This contribution provides an introduction to the principles and techniques of X-ray microtomography to the study of igneous rock textures as well as reviewing the current state of the art. We hope that this short review will encourage more geoscientists to apply X-ray microtomography in their research and that this will lead to new insights into the processes that occur in magmatic (as well as other geological) systems.
Long-term Differences in Tillage and Land Use Affect Intra-aggregate Pore Heterogeneity
Recent advances in computed tomography provide measurement tools to study internal structures of soil aggregates at micrometer resolutions and to improve our understanding of specific mechanisms of various soil processes. Fractal analysis is one of the data analysis tools that can be helpful in evaluating heterogeneity of the intra-aggregate internal structures. The goal of this study was to examine how long-term tillage and land use differences affect intra-aggregate pore heterogeneity. The specific objectives were: (i) to develop an approach to enhance utility of box-counting fractal dimension in characterizing intra-aggregate pore heterogeneity; (ii) to examine intra-aggregate pores in macro-aggregates (4-6 mm in size) using the computed tomography scanning and fractal analysis, and (iii) to compare heterogeneity of intra-aggregate pore space in aggregates from loamy Alfisol soil subjected to 20 yr of contrasting management practices, namely, conventional tillage (chisel plow) (CT), no-till (NT), and native succession vegetation (NS). Three-dimensional images of the intact aggregates were obtained with a resolution of 14.6 {micro}m at the Advanced Photon Source, Argonne National Laboratory, Argonne, IL. Proposed box-counting fractal dimension normalization was successfully implemented to estimate heterogeneity of pore voxel distributions without bias associated with different porosities in soil aggregates. The aggregates from all three studied treatments had higher porosity associated with large (>100 {micro}m) pores present in their centers than in their exteriors. Pores 15 to 60 {micro}m were equally abundant throughout entire aggregates but their distributions were more heterogeneous in aggregate interiors. The CT aggregates had greater numbers of pores 15 to 60 {micro}m than NT and NS. Distribution of pore voxels belonging to large pores was most heterogeneous in the aggregates from NS, followed by NT and by CT. This result was consistent with presence of very large pores associated with former root channels in NT and NS aggregates. Our findings indicate that mechanisms of macro-aggregate formation might differ in their importance in different land use and management practices.
Intra-aggregate Pore Characteristics: X-ray Computed Microtomography Analysis
Abstract not provided
Three Dimensional Petrography of Kernouve: A Story of Vein Formation, Compaction, and Metamorphism
Metallic veins in ordinary chondrites, like those found in Kernouve (H5, S1), have been attributed to impact or shock processes on the parent body. However, Kernouve is widely known to exhibit few traditional signs of shock loading and has a very old {sup 39}Ar-{sup 40}Ar age (4.46 Ga), making the significance of vein formation in Kernouve unclear. One possibility is early vein formation followed by partial obliteration due to thermal metamorphism. We examine this scenario here. The metal vein in Kernouve can be explained as a pre-metamorphic shock-induced structure, given the evidence for current weak compaction and low shock stage. However, it is not clear how one explains high porosity and low shock stage if the meteorite experienced early shock sufficiently strong to mobilize metal into a vein-like structure. Some combination of unusual conditions during shock (e.g. high temperatures) or mobility of metal during metamorphism may be needed. One possible mechanism occurring early on the H chondrite parent body follows: blocks of slightly indurated but porous material were disturbed by an impact which caused a physical concentration of metallic phases akin to slickensides. Shearing of these materials caused the warm, ductile metal grains to be concentrated on rock surfaces. This process would have imparted the rocks with indicators cited by as shock induced. This event happened early in the history of the chondrite otherwise shearing forces would have imparted a preferred orientation upon the metal grains. Subsequent annealing due to radiogenic heating erased any preferential orientation and further coalesced the vein metal. The final compaction of the material occurred yielding the porosity seen in the samples today. The material escaped other major shock episodes.
Limitations in Determining Multifractal Spectra from Pore-Solid Soil Aggregate Images
Multifractal methods have the potential to be useful tools for characterizing spatial distributions of soil pores from microtomographic images of undisturbed soil cores and soil aggregates. The objective of this study was to examine the limitations of multifractal analyses in binary (void and solid) soil images and to explore conditions under which multifractal spectra can be obtained. Multifractal characteristics of binary soil images are bounded within certain limiting values corresponding to nonfractal scaling. In this study, we first addressed the theoretical limitations of multifractal analysis of binary images and examined the nonfractal scaling boundaries in multifractal calculations by the method of moments. Then we developed boundary conditions for multifractal calculations by the direct method. Results revealed that fractal scaling is potentially possible only across a relatively narrow range of cell sizes restricted by the nonfractal scaling boundaries. Moreover, the range of cell sizes where fractal scaling is potentially possible varies with pore size. That is, in multifractal calculations it changes continuously with changes in the q value. For the soil aggregates examined in this study, this range varied from two to eight pixels for low q values to 128 pixels for high q values. The varying range makes calculations of true multifractal spectra for binary soil image data impossible. These results are consistent with a general theoretical notion that binary soil images are not multifractal in a strict mathematical sense. We suggest, however, that application of multifractal formalism can generate 'pseudo-multifractal spectra' that might still be useful for summarizing pore distribution information and for comparing pore data among different agricultural management regimes and soil type.
Structural investigation of amorphous materials at high pressures
A modified diamond anvil cell (DAC) is used for structural studies of amorphous materials at high pressures using a monochromatic synchrotron x-ray beam. The DAC modification includes (1) the use of x-ray transparent seats for a large angular opening for x-ray scattering, and (2) the introduction of a boron gasket insert to increase the sample thickness and to minimize the gasket-hole deformation. A procedure for absorption correction and background subtraction in DAC experiments is described, together with an optimization process for obtaining accurate data of the structure factor and the corresponding pair distribution function. Data for amorphous iron at 67 GPa are presented for demonstration. It is shown that quantitative structural data can be determined for amorphous materials at very high pressures using the DAC. The apparatus should be also useful for structural studies of liquids at high pressures.
Pressure and strain dependence on the strength of sintered polycrystalline Mg[subscript 2]SiO[subscript 4] ringwoodite
Differential stresses in a cylindrical rock of polycrystalline Mg{sub 2}SiO{sub 4} ringwoodite were measured at room temperature with pressures up to 10 GPa, axial strains in excess of 20%, and strain rates between 5 x 10{sup -5} and 4 x 10{sup -6} s{sup -1}, using the deformation-DIA coupled with monochromatic X-rays. The sample exhibited ductile behavior in axial shortening-lengthening cycles with reproducible hysteresis loops, yielding multiple well-defined stress-strain curves. Significant strain hardening was observed beyond the yield point, which occurs at axial strains around 1.5%. Large discrepancies in strength data on ringwoodite reported in previous studies, where no strain information could be obtained, can be reconciled by the strain hardening behavior. Above 8% axial strain, sample stresses reach saturation and the deformation reaches steady state, during which process the ultimate strength increases with hydrostatic pressure but are insensitive to strain rate, suggesting that the sample deforms in low-temperature plasticity regime.
Quantitative Analysis of Flow Processes in a Sand Using Synchrotron-Based X-ray Microtomography
Pore-scale multiphase flow experiments were developed to nondestructively visualize water flow in a sample of porous material using X-ray microtomography. The samples were exposed to similar boundary conditions as in a previous investigation, which examined the effect of initial flow rate on observed dynamic effects in the measured capillary pressure-saturation curves; a significantly higher residual saturation and higher capillary pressures were found when the sample was drained fast using a high air-phase pressure. Prior work applying the X-ray microtomography technique to pore-scale multiphase flow problems has been of a mostly qualitative nature and no experiments have been presented in the existing literature where a truly quantitative approach to investigating the multiphase flow process has been taken, including a thorough image-processing scheme. The tomographic images presented here show, both by qualitative comparison and quantitative analysis in the form of a nearest neighbor analysis, that the dynamic effects seen in previous experiments are likely due to the fast and preferential drainage of large pores in the sample. Once a continuous drained path has been established through the sample, further drainage of the remaining pores, which have been disconnected from the main flowing water continuum, is prevented.
Grain-size control in situ at high pressures and high temperatures in a diamond-anvil cell
The grain-size distribution and the character of individual grain boundaries in microcrystalline networks play a significant role in material properties, such as melting temperature, diffusion coefficients, resistivity, optical absorption, elastic constants, phase transformation pressure, and so on. In this study, the grain size of NaCl, SiO{sub 2} and FeC{sub 3} is controlled in situ at high pressures over the entire range of the length scale of crystallinity: single-crystal, micro-/nanocrystalline and amorphous materials within a volume commensurate with the size of the probing X-ray beam. The structure refinement of high-pressure samples from X-ray diffraction data can be significantly improved by controlling grain size by selecting the structure of starting materials and following certain high pressure-temperature-time paths.
Facilities for high-pressure research with the diamond anvil cell at GSECARS
An overview of facilities for high-pressure research with the diamond anvil cell (DAC) at the GeoSoilEnviroCARS (GSECARS) sector at the Advanced Photon Source (Argonne, Illinois) is presented. There are three operational experimental stations (13-ID-C, 13-ID-D and 13-BM-D) where DAC instrumentation is installed for various types of experiments at high pressure and extreme temperature conditions. A fourth station (13-BM-C) is under construction and will be operational in 2006. While most X-ray diffraction experiments have been undertaken with powder samples so far, there is a growing demand for single-crystal diffraction (SCD) at high pressure. As one of the principal components at GSECARS, SCD is currently under rapid development. Other relevant techniques have also been developed for obtaining complementary information from powder or single-crystal samples at high pressure. For example, an on-line Brillouin system is installed and operational at 13-BM-D for acoustic velocity and single-crystal elasticity determinations. In addition, various X-ray spectroscopy techniques (e.g. X-ray emission and X-ray Raman) are employed for measuring electronic and magnetic properties. Future developments are discussed with the DAC program at GSECARS.
High-Pressure X-ray Tomography Microscope: Synchrotron Computed Microtomography at High Pressure and Temperature
A new apparatus has been developed for microtomography studies under high pressure. The pressure generation mechanism is based on the concept of the widely used Drickamer anvil apparatus, with two opposed anvils compressed inside a containment ring. Modifications are made with thin aluminum alloy containment rings to allow transmission of x rays. Pressures up to 8 GPa have been generated with a hydraulic load of 25 T. The modified Drickamer cell is supported by thrust bearings so that the entire pressure cell can be rotated under load. Spatial resolution of the high pressure tomography apparatus has been evaluated using a sample containing vitreous carbon spheres embedded in FeS matrix, with diameters ranging from 0.01 to 0.2 mm. Spheres with diameters as small as 0.02 mm were well resolved, with measured surface-to-volume ratios approaching theoretical values. The sample was then subject to a large shear strain field by twisting the top and bottom Drickamer anvils. Imaging analysis showed that detailed microstructure evolution information can be obtained at various steps of the shear deformation, allowing strain partition determination between the matrix and the inclusions. A sample containing a vitreous Mg{sub 2}SiO{sub 4} sphere in FeS matrix was compressed to 5 GPa, in order to evaluate the feasibility of volume measurement by microtomography. The results demonstrated that quantitative inclusion volume information can be obtained, permitting in situ determination of P-V-T equation of state for noncrystalline materials.
High quality x-ray absorption spectroscopy measurements with long energy range at high pressure using diamond anvil cell
We describe an approach for acquiring high quality x-ray absorption fine structure (XAFS) spectroscopy spectra with wide energy range at high pressure using diamond anvil cell (DAC). Overcoming the serious interference of diamond Bragg peaks is essential for combining XAFS and DAC techniques in high pressure research, yet an effective method to obtain accurate XAFS spectrum free from DAC induced glitches has been lacking. It was found that these glitches, whose energy positions are very sensitive to the relative orientation between DAC and incident x-ray beam, can be effectively eliminated using an iterative algorithm based on repeated measurements over a small angular range of DAC orientation, e.g., within {+-}3{sup o} relative to the x-ray beam direction. Demonstration XAFS spectra are reported for rutile-type GeO{sub 2} recorded by traditional ambient pressure and high pressure DAC methods, showing similar quality at 440 eV above the absorption edge. Accurate XAFS spectra of GeO{sub 2} glass were obtained at high pressure up to 53 GPa, providing important insight into the structural polymorphism of GeO{sub 2} glass at high pressure. This method is expected be applicable for in situ XAFS measurements using a diamond anvil cell up to ultrahigh pressures.
Structure and behavior of the barringerite Ni end-member, Ni[subscript 2]P, at deep Earth conditions and implications for natural Fe-Ni phosphides in planetary cores
High pressure and high temperature behavior of synthetic Ni{sub 2}P has been studied in a laser-heated diamond anvil cell up to 50 GPA and 2200 K. Incongruent melting associated with formation of pyrite-type NiP{sub 2} and amorphous Ni-P alloy was found at an intermediate pressure range, between 6.5 and 40 GPa. Above GPa, Ni{sub 2}P melts congruently. At room conditions, Ni{sub 2}P has hexagonal C22-type structure, and without heating it remains in this structure to at least 50 GPa. With a bulk modulus K{sub 0} = 201(8) GPa and K' = 4.2(6), Ni{sub 2}P is noticeable less compressible than hcp Fe, as well as all previously described iron phosphides, and its presence in the Earth core would favorable lower the core density. In contrast to Fe{sub 2}P, the c/a ratio in Ni{sub 2}P decreases on compression because of the lack of ferromagnetic interaction along the c direction. Lack of the C22{yields}C23 transition in the Ni{sub 2}P rules out a stabilizing effect of Ni on the orthorhombic phase of natural (Fe{sub 1-x}Ni{sub x}){sub 2}P allabogdanite.