Search NASA⌕ Search

Engineering topics

Rivkin, Carl H

Publications and source records attributed to Rivkin, Carl H.

Adapted tube cleaning practices to reduce particulate contamination at hydrogen fueling stations

The higher rate of component failure and downtime during initial operation in hydrogen stations is not well understood. The National Renewable Energy Laboratory (NREL) has been collecting failed components from retail and research hydrogen fueling stations in California and Colorado and analyzing them using an optical zoom and scanning electron microscope. The results show stainless steel metal particulate contamination. While it is difficult to definitively know the origin of the contaminants, a possible source of the metal particulates is improper tube cleaning practices. To understand the impact of different cleaning procedures, NREL performed an experiment to quantify the particulates introduced from newly cut tubes. The process of tube cutting, threading and beveling, which is performed most often during station fabrication, is shown to introduce metal contaminants and thus is an area that could benefit from improved cleaning practices. This paper shows how these particulates can be reduced, which could prevent station downtime and costly repair. These results are from the initial phase of a project in which NREL intends to further investigate the sources of particulate contamination in hydrogen stations.

30 DIRECT ENERGY CONVERSION↗

Empirical Profiling of Cold Hydrogen Plumes Formed from Venting Of LH2 Storage Vessels: Preprint

Liquid hydrogen (LH2) storage is a viable approach to assuring sufficient hydrogen capacity at commercial fuelling stations. Presently, LH2 is produced at remote facilities and then transported to the end-use site by road vehicles (i.e., LH2 tanker trucks). Venting of hydrogen to depressurize the transport storage tank is a routine part of the LH2 delivery process. The behaviour of cold hydrogen plumes has not been well-characterized because empirical field data is essentially non-existent. The NFPA 2 Hydrogen Storage Safety Task Group, which consists of hydrogen producers, safety experts, and CFD modellers, has identified the lack of understanding of hydrogen dispersion during LH2 venting of storage vessel as a critical gap for establishing safety distances at LH2 facilities, especially commercial hydrogen fuelling stations. To address this need, the NREL sensor laboratory, in collaboration with the NFPA 2 Safety Task Group developed the Cold Hydrogen Plume Analyzer to empirically characterize the hydrogen plume formed during LH2 storage tank venting. A prototype Analyzer was developed and field-deployed at an actual LH2 venting operation with critical findings that included: - H2 being detected as much as 2 m lower than the release point, which is not predicted by existing models - A small and inconsistent correlation between oxygen depletion and the hydrogen concentration - A negligible to non-existent correlation between in-situ temperature and the hydrogen concentration The Analyzer is currently being upgraded for enhanced metrological capabilities including improved real-time spatial and temporal profiling of the plume and tracking of prevailing weather conditions. Additional deployments are planned to monitor plume behaviour under different wind, humidity, and temperatures. This data will be shared with the NFPA 2 Safety Task Group and ultimately will be used support theoretical models and code requirements prescribed in NFPA 2.

30 DIRECT ENERGY CONVERSION↗

Regulations, Codes, and Standards (RCS) for Multi-Fuel Motor Vehicle Dispensing Stations

In the United States, requirements for liquid motor vehicle fuelling stations have been in place for many years. Requirements for motor vehicle fuelling stations for gaseous fuels, including hydrogen, are relatively new. These requirements have, in the United States, been developed along different code and standards paths. The liquid fuels have been addressed in a single document and the gaseous fuels have been addressed in documents specific to an individual gas. The result of these parallel processes is that multi-fuel stations are subject to requirements in several fuelling regulations, codes, and standards (RCS). This paper describes a configuration of a multi-fuel motor vehicle fuelling station and provides a detailed breakdown of the codes and standards requirements. The multi-fuel station would dispense what the U.S. Department of Energy defines as the six key alternative fuels: biodiesel, electricity, ethanol, hydrogen, natural gas, and propane. The paper will also identify any apparent gaps in RCS and potential research projects that could help fill these gaps.

33 ADVANCED PROPULSION SYSTEMS↗

Regulations, Codes, and Standards (RCS) for Large-Scale Hydrogen Systems

Hydrogen has potential applications that require larger-scale storage, use, and handling systems than currently are employed in emerging-market fuel cell applications. These potential applications include hydrogen generation and storage systems that would support electrical grid systems. There has been extensive work evaluating regulations, codes, and standards (RCS) for the emerging fuel cell market, such as the infrastructure required to support fuel cell electric vehicles. However, there has not been a similar RCS evaluation and development process for these larger systems. This paper presents an evaluation of the existing RCS in the United States for large-scale systems and identifies potential RCS gaps. This analysis considers large-scale hydrogen technologies that are currently being employed in limited use but may be more widely used as large-scale applications expand. The paper also identifies areas of potential safety research that would need to be conducted to fill the RCS gaps. U.S. codes define bulk hydrogen storage systems but do not define large-scale systems. This paper evaluates potential applications to define a large-scale hydrogen system relative to the systems employed in emerging technologies such as hydrogen fuelling stations. These large-scale systems would likely be of similar size to or larger than industrial hydrogen systems.

08 HYDROGEN↗

Continuous Codes and Standards Improvement (CCSI)

As of 2014, the majority of the codes and standards required to initially deploy hydrogen technologies infrastructure in the United States have been promulgated. These codes and standards will be field tested through their application to actual hydrogen technologies projects. Continuous codes and standards improvement (CCSI) is a process of identifying code issues that arise during project deployment and then developing codes solutions to these issues. These solutions would typically be proposed amendments to codes and standards. The process is continuous because as technology and the state of safety knowledge develops there will be a need to monitor the application of codes and standards and improve them based on information gathered during their application. This paper will discuss code issues that have surfaced through hydrogen technologies infrastructure project deployment and potential code changes that would address these issues. The issues that this paper will address include (1) setback distances for bulk hydrogen storage, (2) code mandated hazard analyses, (3) sensor placement and communication, (4) the use of approved equipment, and (5) system monitoring and maintenance requirements.

08 HYDROGEN↗