Search NASA⌕ Search

Engineering topics

Roach, Benjamin

Publications and source records attributed to Roach, Benjamin.

Sister Rod Destructive Examinations (FY23) Appendix D: Fission Gas, Fuel Burnup, and Fuel Isotopic Measurements

As a part of DOE NE High Burnup Spent Fuel Data Project, Oak Ridge National Laboratory (ORNL) is performing destructive examinations (DEs) of high burnup (HBU) (>45 GWd/MTU) spent nuclear fuel (SNF) rods from the North Anna Nuclear Power Station operated by Dominion Energy. The SNF rods, called sister rods or sibling rods, are all HBU and include four different kinds of fuel rod cladding: standard Zircaloy-4 (Zirc-4), low-tin (LT) Zirc-4, ZIRLO, and M5. The DEs are being conducted to obtain a baseline of the HBU rod’s condition before dry storage and are focused on understanding overall SNF rod strength and durability. Composite fuel and defueled cladding will be tested to derive material properties. Although the data generated can be used for multiple purposes, one primary goal for obtaining the post-irradiation examination data and the associated measured mechanical properties is to support SNF dry storage licensing and relicensing activities by (1) addressing identified knowledge gaps and (2) enhancing the technical basis for post-storage transportation, handling, and subsequent disposition. This appendix documents the status of the ORNL Phase 1 DE activities related to fission gas sample analysis, fuel burnup analysis, and fuel isotopic analysis of selected sister specimens in Phase 1 of the sister rod test program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Determination of Average Burnup in AGR-3/4 Compacts 1-4 and 7-4

The Advanced Gas Reactor (AGR) Fuel Development and Qualification Program third and fourth irradiation experiments (AGR-3/4), originally planned as separate tests, were combined in one test train for irradiation in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). The irradiation test began on December 14, 2011, and ended on April 12, 2014 (Collin 2016). The originally planned AGR-3 and AGR-4 irradiation experiments were both focused on obtaining data on fission product transport to support the improvement of modeling. The AGR-3 experimental plan was focused on gaseous and metallic fission product release from the kernels and diffusion in the coatings during irradiation and post-irradiation safety testing. The AGR-4 experimental plan was focused on diffusivities and sorptivities in the compact matrix and reactor graphite. These two goals were combined in the AGR-3/4 irradiation, which consisted of 12 independently monitored capsules that each contained four AGR-3/4 compacts in a single stack surrounded by an inner ring of matrix or graphite and an outer ring of graphite. Two capsule types were used: a standard capsule and a so-called fuel body, in which the outer graphite ring included a floor and cap that fully enclosed the fuel. The fuel body design supported post-irradiation safety testing of the intact fuel and ring assembly to provide data on fission product transport and release from the matrix and graphite at accident temperatures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclide inventory validation: radiochemical assay data quality and modeling challenges in benchmark models development

Oak Ridge National Laboratory is conducting radiochemical assay experiments, using high-precision analytical protocols validated with a comprehensive quality assurance plan, to expand the nuclide inventory validation basis for high burnup spent nuclear fuel. Preliminary measurement data for key actinides and fission products in two pressurized water reactor spent fuel samples are being used to investigate the impact of measurement data uncertainty on the sample burnup estimation. These measurement data are also being used to examine the impact of assumptions applied when developing best-estimate computational models to simulate fuel irradiation history. The simulations are being performed using depletion capabilities in the SCALE code system. Comparison of calculated and measured nuclide concentrations shows good agreement for the considered nuclides. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Direct isotopic analysis of solid uranium particulates on cotton swipes by microextraction-ICP-MS

Direct isotope ratio analysis of solid uranium particulates on cotton swipes was achieved using a solution-based microextraction technique, coupled to a quadrupole inductively coupled plasma - mass spectrometer (ICP-MS). This microextraction-ICP-MS methodology provides rapid isotopic analysis which could be applicable to nuclear safeguards measurements. Particulates of uranyl nitrate hexahydrate (UO 2 (NO 3 ) 2 ·6H 2 O) and uranyl fluoride (UO 2 F 2 ) ranging from 6 μm to 40 μm in length were transferred to cotton swipes with a particle manipulator. The microextraction probe then delivers a 5% nitric acid (HNO3) solvent onto the swipe surface to extract the uranium species. The extracted sample is then delivered to the ICP-MS for isotopic determination. The majority of uranium signal (~99% and ~94% for UO2(NO3)2·6H2O and UO 2 F 2 , respectively) was detected in the first 15 s extraction, while subsequent extractions on the same location had low or no U signal, suggesting near complete removal of the solid uranium compounds from the swipe surface. Ten samples (for each of the uranium compounds), were analyzed for their isotopic composition. For UO 2 (NO 3 ) 2 ·6H 2 O, the determined isotope ratios resulted in a % relative difference (% RD) from the referenced isotope ratios of 0.97, 1.0, and 7.3% for 234 U/ 238 U, 235 U/ 238 U, and 236 U/ 238 U, respectively. The % RD of the UO 2 F 2 isotope ratios were 1.9 and 0.60% for 234 U/ 238 U and 235 U/ 238 U, respectively. The preliminary limits of detection were determined to be 0.002, 0.4, and 60 pg for 234 U, 235 U and 238 U, respectively This work demonstrates that microextraction ICP-MS is a rapid and sensitive method that could directly determine uranium isotope ratios of UO 2 (NO 3 ) 2 ·6H 2 O and UO 2 F 2 particulates on cotton swipes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Update on the High Precision Titration Method for Uranium Assay Supported by NBL Program Office

The NBL Program Office (NBL PO) has coordinated with Oak Ridge National Laboratory (ORNL) to implement the High Precision Titration (HPT) method for uranium assay measurements. The measurement method has been successfully developed and qualified, therefore ORNL has progressed to performing analyzes critical to the mission of the NBL PO. The HPT method is vital to producing the next generation of certified reference materials for uranium assay and isotopic abundance. The work described here focused on establishing traceability of the method to the NIST SRM 136 potassium dichromate series, and focused on investigating small differences between SRM 136e and 136f. The NBL PO evaluated the history of all of its primary uranium reference materials, including CRM 112A natural uranium metal, and worked with NIST in investigating the small differences in the dichromate SRM’s. ORNL performed comparative experiments on SRM 136e and 136f using CRM 112A. The results of the experiment will be presented here, along with NBL PO’s plans to re-evaluate the CRM 112A certified uncertainty to comply with JCGM 100, “Guide to the expression of uncertainty in measurement.”

Rogers, Kayron↗

Direct Uranium Isotopic Analysis of Swipe Surfaces by Microextraction-ICP-MS

The ability to directly measure uranium isotope ratios on environmental swipes has been achieved through a solution-based microextraction process and represents a significant advancement toward the development of a rapid method to analyze international nuclear safeguard samples. Here, a microextraction probe is lowered and sealed onto the swipe surface, and analytes within the sampling site (~8 mm2) are dissolved and extracted into a flowing solvent of 2% nitric acid (HNO 3 ). The mobilized species are subsequently directed into an inductively coupled plasma-mass spectrometer (ICP-MS) for accurate and precise isotope ratio determination. This work highlights the novelty of the sampling mechanism, particularly with the direct coupling of the microextraction probe to the ICP-MS and measurement of uranium isotope ratios. The preliminary method detection limit for the microextraction-ICP-MS method, utilizing a quadrupole-based MS, was determined to be ~50 pg of 238 U. Additionally, precise and accurate isotope ratio measurements were achieved on uranium reference materials for both the major ( 235 U/ 238 U) and minor ( 234 U/ 238 U and 236 U/ 238 U) ratios. While the present work is focused on directly measuring uranium isotopic systems on swipe surfaces for nuclear safeguards and verification applications, the benefits would extend across many applications in which direct solid sampling is sought for elemental and isotopic analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New Capability at ORNL: High Precision Uranium Titration

Destructive analytical measurements establish a nuclear facility’s nuclear material inventory and inventory differences for Nuclear Material Accountancy and Control. A nuclear laboratory’s ability to perform accurate high-precision analytical measurements is key for tracking large inventories within a facility’s material balance areas and during production to track material movement through dynamic processes. For uranium, these measurements are made by using several established high-precision measurement protocols. These include isotope dilution mass spectrometry, gravimetry, and potentiometric titrations. Whatever measurement technique a nuclear lab chooses to use, reference materials (RMs) with certified attributes and accompanying uncertainties are used to calibrate measurement systems, and are the cornerstone for accurate results. In addition to calibration, RMs provide for metrological traceability, are used for method development and validation, and thus provide critical evaluations of the appropriateness and performance of analytical processes used. Evaluations may include validation that a method is fit-for-purpose, quantification of systematic and random biases, and the evaluation of long-term and short-term performance metrics. High-precision measurement techniques require that measured attributes be certified to a high degree of precision in the RMs used—ultimately, to a higher degree than that of the measurement technique itself. The US authority on the production of special nuclear material Certified Reference Materials is the NBL Program Office (NBLPO), formally known as New Brunswick Laboratory (NBL). The NBLPO is responsible for the sales and distribution of existing NBL certified reference materials (CRMs) and for the production of the next generation of nuclear RMs. To accomplish its mission, NBLPO is establishing key base capabilities within the DOE laboratory complex that formerly existed at the NBL laboratory. The Nuclear Analytical Chemistry (NAC) section within the Chemical Sciences Division (CSD) at Oak Ridge National Laboratory (ORNL) is currently working with NBLPO to set up laboratory and measurement capabilities to provide measurements and capabilities for production and/or recertification of existing and future CRMs for uranium assay. The NBL-developed high-precision titration (HPT) method is a critically-evaluated, extremely precise and accurate primary method utilized for the determination of uranium content in a variety of uranium materials. The HPT method, combined with detailed balance weighing protocols, provides for an analytical methodology that is unsurpassed in precision and one in which all sources of error have been evaluated, a requirement of CRM certification. HPT capability within the United States was lost with the closure of the labs at NBL. The NAC has been collaborating with NBLPO to stand up and demonstrate the capability to perform uranium assay via HPT at ORNL. HPT can produce results with an expanded uncertainty of approximately 0.01% for pure uranium compounds, with typical precisions of <0.006%. The major tasks required to stand up the method at ORNL were the refurbishment of a dedicated lab and equipment setup, procedure development, analyst training, establishing method-specific quality assurance, and qualification of an analyst to perform the method. This report summarizes these tasks, outlines the documents drafted, and gives the outcome of the qualification titrations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗