Search NASA⌕ Search

Engineering topics

Robertson, S

Publications and source records attributed to Robertson, S.

Measurement of the multi-TeV neutrino interaction cross-section with IceCube using Earth absorption

We report that neutrinos interact only very weakly, so they are extremely penetrating. The theoretical neutrino-nucleon interaction cross-section, however, increases with increasing neutrino energy, and neutrinos with energies above 40 teraelectronvolts (TeV) are expected to be absorbed as they pass through the Earth. Experimentally, the cross-section has been determined only at the relatively low energies (below 0.4 TeV) that are available at neutrino beams from accelerators. Here we report a measurement of neutrino absorption by the Earth using a sample of 10,784 energetic upward-going neutrino-induced muons. The flux of high-energy neutrinos transiting long paths through the Earth is attenuated compared to a reference sample that follows shorter trajectories. Using a fit to the two-dimensional distribution of muon energy and zenith angle, we determine the neutrino-nucleon interaction cross-section for neutrino energies 6.3-980 TeV, more than an order of magnitude higher than previous measurements. The measured cross-section is about 1.3 times the prediction of the standard model, consistent with the expectations for charged- and neutral-current interactions. We do not observe a large increase in the cross-section with neutrino energy, in contrast with the predictions of some theoretical models, including those invoking more compact spatial dimensions or the production of leptoquarks. This cross-section measurement can be used to set limits on the existence of some hypothesized beyond-standard-model particles, including leptoquarks.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-P-35: A Multi-Institutional Plan Quality Checking Tool Built On Oncospace: A Shared Radiation Oncology Database System

Purpose: Late toxicity from radiation to critical structures limits the possible dose in Radiation Therapy. Perfectly conformal treatment of a target is not realizable, so the clinician must accept a certain level of collateral radiation to nearby OARs. But how much? General guidelines exist for healthy tissue sparing which guide RT treatment planning, but are these guidelines good enough to create the optimal plan given the individualized patient anatomy? We propose a means to evaluate the planned dose level to an OAR using a multi-institutional data-store of previously treated patients, so a clinician might reconsider planning objectives. Methods: The tool is built on Oncospace, a federated data-store system, which consists of planning data import, web based analysis tools, and a database containing:1) DVHs: dose by percent volume delivered to each ROI for each patient previously treated and included in the database.2) Overlap Volume Histograms (OVHs): Anatomical measure defined as the percent volume of an ROI within a given distance to target structures.Clinicians know what OARs are important to spare. For any ROI, Oncospace knows for which patients’ anatomy that ROI was harder to plan in the past (the OVH is less). The planned dose should be close to the least dose of previous patients. The tool displays the dose those OARs were subjected to, and the clinician can make a determination about the planning objectives used.Multiple institutions contribute to the Oncospace Consortium, and their DVH and OVH data are combined and color coded in the output. Results: The Oncospace website provides a plan quality display tool which identifies harder to treat patients, and graphically displays the dose delivered to them for comparison with the proposed plan. Conclusion: The Oncospace Consortium manages a data-store of previously treated patients which can be used for quality checking new plans. Grant funding by Elekta.

60 APPLIED LIFE SCIENCES↗

SU-F-R-47: Quantitative Shape Relationship Analysis of PTV Modification for Critical Anatomy Sparing and Its Impact On Pathologic Response for Neoadjuvant Stereotactic Radiotherapy for Pancreatic Cancer

Purpose: Stereotactic body radiation therapy (SBRT) may be used to increase surgery candidacy in borderline resectable (BRPC) and locally advanced (LAPC) pancreatic cancer. However, the planning target volume (PTV) may need to be limited to avoid toxicity when the gross tumor volume (GTV) is anatomically involved with surrounding critical structures. Our study aims to characterize the coverage of GTV and investigate the association between modified PTV and pathologic (pCR) or near pathologic (npCR) complete response rates determined from the surgical specimen. Methods: Patients treated with neoadjuvant pancreas SBRT followed by surgery from 2010–2015 were selected from Oncospace. Overlap volume histogram (OVH) analysis was performed to determine the extent of compromise of the PTV from both the GTV and a standard target (GTV+3mm). Subsequently, normalized overlap volume (%) was calculated for: (1) GTV-PTV, and (2) GTV+3mm expansion-PTV. A logistic regression model was used to identify the association between the overlap ratios and ≥ npCR(pCR/npCR) stratified by active breathing control (ABC) versus free-breathing status. Results: Eighty-one (BRPC: n=42, LAPC: n=39) patients were available for analysis. Nearly 40% (31/81) had ≥npCR and 75% (61/81) were able to complete ABC. Mean coverage of the GTV-PTV was 92.6% (range, 59.9%–100%, SD = 8.68) and coverage of the GTV+3mm expansion-PTV was 85. 2% (range, 59.9% −100.0%, SD= 8.67). Among the patients with ABC, every 10% increase in GTV coverage doubled the odds to have ≥npCR (OR = 1.82, p=0.06). Coverage of GTV+3mm expansion was not associated with ≥npCR regardless of ABC status. Conclusion: Preferential sparing of critical anatomy over GTV-PTV coverage with ABC management suggests worse ≥npCR rates for neoadjuvant SBRT in BRPC and LAPC. Limiting the GTV and GTV+3mm expansion in free-breathing patients was not associated with pathologic response perhaps due to larger GTV definitions as a result of motion artifacts in free-breathing CT scans. Collaboration with Toshiba, Elekta, and Phillips.

60 APPLIED LIFE SCIENCES↗

SU-E-P-26: Oncospace: A Shared Radiation Oncology Database System Designed for Personalized Medicine, Decision Support, and Research

Purpose: Advancement in Radiation Oncology (RO) practice develops through evidence based medicine and clinical trial. Knowledge usable for treatment planning, decision support and research is contained in our clinical data, stored in an Oncospace database. This data store and the tools for populating and analyzing it are compatible with standard RO practice and are shared with collaborating institutions. The question is - what protocol for system development and data sharing within an Oncospace Consortium? We focus our example on the technology and data meaning necessary to share across the Consortium. Methods: Oncospace consists of a database schema, planning and outcome data import and web based analysis tools.1) Database: The Consortium implements a federated data store; each member collects and maintains its own data within an Oncospace schema. For privacy, PHI is contained within a single table, accessible to the database owner.2) Import: Spatial dose data from treatment plans (Pinnacle or DICOM) is imported via Oncolink. Treatment outcomes are imported from an OIS (MOSAIQ).3) Analysis: JHU has built a number of webpages to answer analysis questions. Oncospace data can also be analyzed via MATLAB or SAS queries.These materials are available to Consortium members, who contribute enhancements and improvements. Results: 1) The Oncospace Consortium now consists of RO centers at JHU, UVA, UW and the University of Toronto. These members have successfully installed and populated Oncospace databases with over 1000 patients collectively.2) Members contributing code and getting updates via SVN repository. Errors are reported and tracked via Redmine. Teleconferences include strategizing design and code reviews.3) Successfully remotely queried federated databases to combine multiple institutions’ DVH data for dose-toxicity analysis (see below – data combined from JHU and UW Oncospace). Conclusion: RO data sharing can and has been effected according to the Oncospace Consortium model: http://oncospace.radonc.jhmi.edu/ . John Wong - SRA from Elekta; Todd McNutt - SRA from Elekta; Michael Bowers - funded by Elekta.

60 APPLIED LIFE SCIENCES↗

SU-E-J-32: Calypso(R) and Laser-Based Localization Systems Comparison for Left-Sided Breast Cancer Patients Using Deep Inspiration Breath Hold

Purpose: Our institution uses a manual laser-based system for primary localization and verification during radiation treatment of left-sided breast cancer patients using deep inspiration breath hold (DIBH). This primary system was compared with sternum-placed Calypso(R) beacons (Varian Medical Systems, CA). Only intact breast patients are considered for this analysis. Methods: During computed tomography (CT) simulation, patients have BB and Calypso(R) surface beacons positioned sternally and marked for free-breathing and DIBH CTs. During dosimetry planning, BB longitudinal displacement between free breathing and DIBH CT determines laser mark (BH mark) location. Calypso(R) beacon locations from the DIBH CT are entered at the Tracking Station. During Linac simulation and treatment, patients inhale until the cross-hair and/or lasers coincide with the BH Mark, which can be seen using our high quality cameras (Pelco, CA). Daily Calypso(R) displacement values (difference from the DIBH-CT-based plan) are recorded.The displacement mean and standard deviation was calculated for each patient (77 patients, 1845 sessions). An aggregate mean and standard deviation was calculated weighted by the number of patient fractions.Some patients were shifted based on MV ports. A second data set was calculated with Calypso(R) values corrected by these shifts. Results: Mean displacement values indicate agreement within 1±3mm, with improvement for shifted data (Table). Conclusion: Both unshifted and shifted data sets show the Calypso(R) system coincides with the laser system within 1±3mm, demonstrating either localization/verification system will Resultin similar clinical outcomes. Displacement value uncertainty unilaterally reduces when shifts are taken into account.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-544: A Radiation Oncology-Specific Multi-Institutional Federated Database: Initial Implementation

Purpose: To implement a common database structure and user-friendly web-browser based data collection tools across several medical institutions to better support evidence-based clinical decision making and comparative effectiveness research through shared outcomes data. Methods: A consortium of four academic medical centers agreed to implement a federated database, known as Oncospace. Initial implementation has addressed issues of differences between institutions in workflow and types and breadth of structured information captured. This requires coordination of data collection from departmental oncology information systems (OIS), treatment planning systems, and hospital electronic medical records in order to include as much as possible the multi-disciplinary clinical data associated with a patients care. Results: The original database schema was well-designed and required only minor changes to meet institution-specific data requirements. Mobile browser interfaces for data entry and review for both the OIS and the Oncospace database were tailored for the workflow of individual institutions. Federation of database queries--the ultimate goal of the project--was tested using artificial patient data. The tests serve as proof-of-principle that the system as a whole--from data collection and entry to providing responses to research queries of the federated database--was viable. The resolution of inter-institutional use of patient data for research is still not completed. Conclusions: The migration from unstructured data mainly in the form of notes and documents to searchable, structured data is difficult. Making the transition requires cooperation of many groups within the department and can be greatly facilitated by using the structured data to improve clinical processes and workflow. The original database schema design is critical to providing enough flexibility for multi-institutional use to improve each institution s ability to study outcomes, determine best practices, and support research. The project has demonstrated the feasibility of deploying a federated database environment for research purposes to multiple institutions.

60 APPLIED LIFE SCIENCES↗

Dust Charging and Transport on Surfaces

In this paper, we review laboratory studies of dust transport on surfaces in plasmas, performed for a number of different mechanisms: 1) Dust particles were levitated in plasma sheaths by electrostatic forces balancing the gravitational force. 2) Dust was observed to spread over and lift off a surface that repels electrons in a plasma. 3) Dust was transported on surfaces having different secondary electron yields in plasma with an electron beam as a consequence of differential charging. 4) We also report a mechanism of dust transport by electric fields occurring at electron beam impact/shadow boundaries. These processes are candidates to explain the formation of dust ponds that were recently observed in craters on the asteroid Eros by the NEAR Shoemaker spacecraft.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Dust Accelerator Facility of the Colorado Center for Lunar Dust and Atmospheric Studies

The NASA Lunar Institute's Colorado Center for Lunar Dust and Atmospheric Studies has recently completed the construction of a new experimental facility to study hypervelocity dust impacts. The installation includes a 3 MV Pelletron, accelerating small particles in the size range of 0.1 to few microns to velocities in the range of 1 to 100 km/s. Here we report the capabilities of our facility, and the results of our first experiments.

43 PARTICLE ACCELERATORS↗

Implementation And Performance of the ATLAS Second Level Jet Trigger

ATLAS is one of the four major LHC experiments, designed to cover a wide range of physics topics. In order to cope with a rate of 40MHz and 25 interactions per bunch crossing, the ATLAS trigger system is divided in three different levels. The jet selection starts at first level with dedicated processors that search for high E{sub T} hadronic energy depositions. At the LVL2, the jet signatures are verified with the execution of a dedicated, fast jet reconstruction algorithm, followed by a calibration algorithm. Three possible granularities have been proposed and are being evaluated: cell based (standard), energy sums calculated at each Front-End Board and the use of the LVL1 Trigger Towers. In this presentation, the design and implementation of the jet trigger of ATLAS will be discussed in detail, emphasazing the major difficulties of each selection step. The performance of the jet algorithm, including timing, efficiencies and rates will also be shown, with detailed comparisons of the different unpacking modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Frequency shifting at fiber-optical event horizons: The effect of Raman deceleration

Pulses in fibers establish analogs of the event horizon [Philbin et al., Science 319, 1367 (2008)]. At a group-velocity horizon, the frequency of a probe wave is shifted. We present a theoretical model of this frequency shifting, taking into account the deceleration of the pulse caused by the Raman effect. The theory shows that the probe-wave spectrum is sensitive to details of the probe-pulse interaction. Our results indicate an additional loss mechanism in the experiment [Philbin et al., Science 319, 1367 (2008)] that has not been accounted for. Our analysis is also valid for more general cases of the interaction of dispersive waves with decelerated solitons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Surface-Plasma Interaction on the Moon

The electrostatic levitation and transport of lunar dust remains a controversial science issue since the Apollo era. As a function of time and location, the lunar surface is exposed to solar wind plasma, UV radiation, and/or the plasma environment of our magnetosphere. Dust grains on the lunar surface emit and absorb plasma particles and are exposed to solar UV photons. There are several in situ and remote sensing observations that indicate that dusty plasma processes are responsible for the mobilization and transport of lunar soil. We briefly discuss the existing observations, and report on a series of experiments that address some of the most relevant processes acting on dusty surfaces exposed to plasmas and UV radiation.

79 ASTRONOMY AND ASTROPHYSICS↗