Streaked sub-ps-resolution x-ray line shapes and implications for solid-density plasma dynamics (invited)
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Rocca, J J.
Explore the source record for details and available documents.
A high-resolution x-ray spectrometer was coupled with an ultrafast x-ray streak camera to produce time-resolved line shape spectra measured from hot, solid-density plasmas. A Bragg crystal was placed near a laser-produced plasma to maximize throughput; alignment tolerances were established by raytracing. The streak camera produced single-shot time-resolved spectra, heavily sloped due to photon time-of-flight differences, with sufficient reproducibility to accumulate photon statistics. The images are time-calibrated by the slope of streaked spectra and dewarped to generate spectra emitted at different times defined at the source. The streaked spectra demonstrate the evolution of spectral shoulders and other features on ps timescales, showing the feasibility of plasma parameter measurements on the rapid timescales necessary to study high-energy-density plasmas.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Surfaces covered with nanostructures, such as nanowire arrays, are shown to facilitate a significantly higher absorption of laser energy as compared to flat surfaces. Due to the efficient coupling of the laser energy, highly energetic electrons are produced, which in turn can emit intense ultrafast X-ray pulses. Full three dimensional PIC simulations are used to analyse the behaviour of arrays of carbon nanowires 400 nm in diameter, irradiated by a 400-nm laser pulse of 60-fs duration at FWHM and a vector potential of α{sub 0} = 18. We analyse the ionisation dynamics of the nanowires. The difference of the ionisation strength and structure between linearly and circularly polarised laser beam is investigated. The nanowires are found to be fully ionised after about 30 laser cycles. Circularly polarised light reveals a slightly stronger ionisation effect. (extreme laser radiation: physics and fundamental applications)
The authors describe a photolithographic scheme based on the replication of a periodic transparent mask in a photoresist utilizing the coherent self-imaging Talbot effect. A periodic two-dimensional diffractive structure (or Talbot mask) composed of unit tiles distributed in a square matrix was illuminated by a coherent extreme ultraviolet (EUV) beam from a table top EUV laser. The illumination beam was reflected in a spherical mirror and the Talbot mask was placed in the path of the convergent beam. At designed locations determined by the Talbot distance, reduced replicas of the mask were obtained and used to print the slightly de-magnified copies of the mask on the surface of a photoresist. Experimental results showing the de-magnification effect are in good agreement with the diffraction theory. The limits of the technique are discussed.
An inner-shell photoionized x-ray laser pumped by the Linac Coherent Light Source (LCLS) free electron laser has been proposed recently. The measurement of the on-axis 849 eV Ne K{alpha} laser and protection of the x-ray spectrometer from damage require attenuation of the 1 keV LCLS beam. An Al/Cu foil combination is well suited, serving as a low energy bandpass filter below the Cu L-edge at 933 eV. A high resolution grating spectrometer is used to measure the transmission of a candidate filter with an intense laser-produced x-ray backlighter developed at the Lawrence Livermore National Laboratory Jupiter Laser Facility Janus. The methodology and discussion of the observed fine structure above the Cu L-edge will be presented.
Abstract not provided
Abstract not provided
We describe recent advances in the demonstration of table-top full field microscopes that use soft x-ray lasers for illumination. We have achieved wavelength resolution and single shot exposure operation with a very compact 46.9 nm microscope based on a desk-top size capillary discharge laser. This {lambda}-46.9 nm microscope has been used to capture full field images of a variety of nanostructure systems and surfaces. In a separate development we have demonstrated a zone plate microscope that uses {lambda}=13.2 nm laser illumination to image absorption defects in an extreme ultraviolet lithography (EUVL) mask in the same geometry used in a 4x demagnification EUVL stepper. Characterization of the microscope’s transfer function shows it can resolve 55 nm half period patterns. With these capabilities, the {lambda}-13.2 nm microscope is well suited for evaluation of pattern and defect printability of EUVL masks for the 22 nm node.
We present results on a table-top microscope that uses an EUV stepper geometry to capture full-field images with a halfpitch spatial resolution of 55 nm. This microscope uses a 13.2 nm wavelength table-top laser for illumination and acquires images of reflective masks with exposures of 20 seconds. These experiments open the path to the realization of high resolution table-top imaging systems for actinic defect characterization.
We report the tabletop acquisition of soft x-ray holographic images of nanostructures with a spatial resolution of 46{+-}2 nm, nearly equal to the wavelength of the illumination. Holograms of carbon nanotubes were recorded using a compact, tabletop capillary-discharge soft x-ray laser emitting at 46.9 nm in a high-numerical-aperture Gabor configuration.