Engineering topics
Rockward, Tommy
Publications and source records attributed to Rockward, Tommy.
LANL-Treadstone Update: 316SS Corrosion Testing [Slides]
Ecorr shows decay as cycles increase. Icorr increases up until 1,000 cycles.
Welcome Navajo Technical University and San Juan College [Slides]
Abstract not provided.
Assessment and Non-Destructive Evaluation of the Influence of Residual Solvent on a Two-Part Epoxy-Based Adhesive Using Ultrasonics
Polymers are increasingly being used in higher demanding applications due to their ability to tailor the properties of structures while allowing for a weight and cost reduction. Solvents play an important role in the manufacture of polymeric structures since they allow for a reduction in the polymer’s viscosity or assist with the dispersion of fillers into the polymer matrix. However, the incorrect removal of the solvent affects both the physical and chemical properties of polymeric materials. The presence of residual solvent can also negatively affect the curing kinetics and the final quality of polymers. Destructive testing is mainly performed to characterize the properties of these materials. However, this type of testing involves using lab-type equipment that cannot be taken in-field to perform in situ testing and requires a specific sample preparation. Here, a method is presented to non-destructively evaluate the curing process and final viscoelastic properties of polymeric materials using ultrasonics. In this study, changes in longitudinal sound speed were detected during the curing of an aerospace epoxy adhesive as a result of variations in polymer chemistry. To simulate the presence of residual solvent, samples containing different weight percentages of isopropyl alcohol were manufactured and tested using ultrasonics. Thermogravimetric analysis was used to show changes in the decomposition of the adhesive due to the presence of IPA within the polymer structure. Adding 2, 4, and 6 wt.% of IPA decreased the adhesive’s lap shear strength by 40, 58, and 71%, respectively. Ultrasonics were used to show how the solvent influenced the curing process and the final sound speed of the adhesive. Young’s modulus and Poisson’s ratio were determined using both the longitudinal and shear sound speeds of the adhesive. Using ultrasonics has the potential to non-invasively characterize the quality of polymers in both an in-field and manufacturing settings, ensuring their reliability during use in demanding applications.
Review—Micro-Fuel Cell Principal Biosensors for Monitoring Transdermal Volatile Organic Compounds in Humans
Knowledge of transduction mechanisms in biosensing applications paves the way for ultrasensitive and dynamic detection in living systems. Real-world biosensing applications where ultra-sensitivity and dynamic detection are paramount include monitoring the anesthetic agent concentration during surgery; the slightest variation in concentration can potentially result in a life-threatening overdose or, on the other end of the spectrum, the patient’s awareness during the procedure. We review the benefits and functions of the transcutaneous biosensor device compared with other current technology and discuss the sensor’s capability to accurately measure volatile anesthetic gas concentration in blood using fuel cell technology. We review fundamental concepts of fuel-cell technology for wearable bio-sensing applications. The fuel cell sensor can also continuously monitor other volatile organic compounds making it versatile with numerous potential applications.
Fuel Quality Assurance Research and Development and Impurity Testing in Support of Codes and Standards [Slides]
Abstract not provided.
Allyship:" How Can I Help?" [Slides]
Lifelong process of building relationships based on trust, consistency, and accountability with marginalized individuals and/or groups of people.
ASTM D03 Workshop: Developing a Hydrogen Contamination Detector Analyzer [Slides]
Non-hydrogen constituents in the fuel steam can cause irreversible damage to FC systems and therefore should be avoided. The objectives are: 1. Develop a low-cost fast response device (analyzer) to measure impurities in a dry hydrogen fuel stream at or above the SAE J2719 levels, 2. Develop understanding of a working mechanism and improve the analyzer by identifying the best materials and their configuration, and 3. Test the analyzer in real-world environments.
Challenges of Investigating Redox Reactions in Room Temperature Ionic Liquids [Slides]
The goal of this project is to understand the effects of the morphology and chemical properties of ionic liquids (IL) on the heterogeneous electron transfer processes of simple inorganic ions. This project will seek to understand the fundamental chemical and physical phenomena in ionic liquids through electrochemical, and material characterization techniques.
Adhesion of Titanium Coatings on Additively Manufactured Stainless Steel [Slides]
Additive manufacturing can improve fuel cell development by increasing design development speed, enabling complex designs through more flexible fabrication, and reducing wasted excess material. The goal of the project is to develop a process for strongly adhering a coating of titanium to additively manufactured stainless steel.
Adhesion of Titanium Coatings on Additively Manufactured Stainless Steel
The ongoing global climate change crisis has brought attention to the urgent need to reduce greenhouse gas emissions from vehicles by providing alternative zero-emission fueling technologies. Prevailing vehicles are dependent on fossil fuels and contribute to climate change by creating emissions of carbon dioxide. In 2019, transportation was the largest contributing economic sector to the U.S. greenhouse gas emissions total at 29% [1]. By converting vehicle fueling to an alternative method, major reductions in greenhouse gas emissions can be achieved. Hydrogen fuel cells are one potential alternative capable of generating electricity from hydrogen while emitting only water. Several obstacles hinder the development of hydrogen fuel cells as a viable alternative, including the manufacturability of bipolar plates.
Breaking the Ice: "I Was Only Trying to Help" [Slides]
This Breaking the Ice presentation discusses guidelines for: the initial meeting, visibility, being personable, the role of the mentee, creating a productive environment, and the path forward.
Investigation of Membrane Chemical Degradation as a Function of Catalyst Platinum Loading
Membrane chemical degradation is one of many factors that can impact fuel cell durability. Additionally, the fuel cell’s lifetime heavily depends on the membrane and its ability to maintain chemical and mechanical integrity. Previous studies indicate that chemical degradation is due to the formation of hydroxyl radicals that attack the polymer structure resulting in membrane thinning, pinhole formation, and the release of fluoride and sulfate ions. Membrane durability was investigated using ultra-low Pt electrode loadings (≤ 0.1 mg Pt cm -2 ). Accelerated stress testing (US-DOE protocols) demonstrated that the degradation rate was found to increase with higher Pt loadings. This is most likely due to more heterogeneous sites for radical formation due to hydrogen crossover to the cathode. We also explored membrane degradation rates while varying catalyst layer thickness, ionomer to carbon ratio, and types of carbon support. All of the aforementioned variables impact the membrane degradation rates.
Near-UV light assisted green reduction of graphene oxide films through l-ascorbic acid
Not Available
Technology Commercialization Fund (TCF): Hydrogen Contaminant Detector (HCD) (Slides)
Abstract not provided.
Development of an Electrochemical Hydrogen Contaminant Detector
Hydrogen refueling stations (HRSs) that dispense hydrogen to fuel cell vehicles need to ensure the quality of hydrogen to avoid contamination of the vehicle’s expensive fuel cell stacks. Currently, stations verify their fuel quality only periodically to ensure that they meet the strict fuel quality standards specified by either International Organization for Standards (ISO) or Society for Automotive Engineers (SAE). The development of hydrogen contaminant detectors (HCDs) that can provide low cost continuous monitoring at the HRS can be an invaluable asset in protecting fuel cell vehicles from any fuel contamination in-between infrequent expensive analysis of hydrogen fuel quality. An HCD capable of detecting < 200 ppb of CO in hydrogen is presented in this paper. The HCD is based on an electrochemical hydrogen pumping cell whose ultra-low loaded working electrode is poisoned by the contaminant, thus reducing its hydrogen oxidation reaction rate. The hydrogen pumping cell consists of a Nafion® membrane, a sputtered Pt working electrode, a Pt/Ru counter/pseudo-reference electrode and an internal water wicking system that provides humidification to the membrane and electrodes. When this HCD is operated in a pulsed voltammetry mode, it can provide stable CO response for thousands of hours in a HRS.