Search NASA⌕ Search

Engineering topics

Rockwell, Robert D.

Publications and source records attributed to Rockwell, Robert D..

Hybrid Large Eddy Simulation/Reynolds-Averaged Navier–Stokes Analysis of a Premixed Ethylene-Fueled Dual-Mode Scramjet Combustor

Hydrocarbon fuels offer optimal high energy per volume for scramjet applications for sustained hypersonic flight but require additional residence time due to slower ignition delays (compared with hydrogen fuel). The injection of ethylene at the start of the isolator of a dual-mode scramjet combustor, operating in ramjet mode, allows sufficient mixing to achieve efficient premixed turbulent combustion. A cavity flameholder anchors the flame, supplying sufficient radicals to sustain a stable flame in the high-speed environment. This work investigates flame structure and stabilization limits of a new configuration with a scaled-down cavity embedded in the flow path of the combustor with a strut and insert. The cavity is reduced in size by one-third to enable eventual direct numerical simulations of the flame stabilization process. This work, however, focuses on modeling the full isolator/combustor geometry using a hybrid large eddy simulation/Reynolds-averaged Navier–Stokes simulation strategy. Additionally, particle image velocimetry, planar laser-induced fluorescence, coherent anti-Stokes Raman spectroscopy, and pressure measurements are compared with numerical predictions to analyze and characterize the conditions within the combustor, including flame structure, flow velocities, species composition, and wall pressure. An adjustable air throttle in the extender is able to control the placement of the shock train in the isolator and maintain a stable flame at various equivalence ratios. The simulations show reasonably good agreement with the experimental scalar and velocity data and predict a flame angle consistent with premixed turbulent flame-speed correlations.

42 ENGINEERING↗

High-Spatial-Resolution OH PLIF Visualization in a Cavity-Stabilized Ethylene-Air Turbulent Flame

High-spatial-resolution OH planar laser-induced fluorescence was measured for a premixed ethylene-air turbulent flame in an electrically-heated Mach 2 continuous-flow facility (University of Virginia Supersonic Combustion Facility, Configuration E.) The facility comprised a Mach 2 nozzle, an isolator with flush-wall fuel injectors, a combustor with optical access, and an extender. The flame was anchored at a cavity flameholder with a backward-facing step of height 9 mm. The temperature-insensitive Q1(8) transition of OH was excited using laser light of wavelength 283.55 nm. A spatial filter was used to create a laser sheet approximately 25 microns thick based on full-width at half maximum (FWHM). Extension tubes increased the magnification of an intensified camera system, achieving in-plane resolution of 40 microns based on a 50% modulation transfer function (MTF). The facility was tested with total temperature 1200 K, total pressure 300 kPa, local fuel/air equivalence ratios of approximately 0.4, and local Mach number of approximately 0.73 in the combustor. A test case with reduced total temperature and another with reduced equivalence ratio were also tested. PLIF images were acquired along a streamwise plane bisecting the cavity flameholder, from the backward facing step to 120 mm downstream of the step. The smallest observed features in the flow had width of approximately 110 microns. Flame surface density was calculated for OH PLIF images.

Geipel, Clayton M.↗

High-Resolution OH and CH2O Visualization in a Premixed Cavity-Anchored Ethylene-Air Flame in a M = 0.6 Flowfield

OH and CH2O were imaged in a premixed, cavity-anchored, ethylene-air turbulent flame using a high resolution planar laser-induced fluorescence (PLIF) system. The electrically-heated, continuous flow facility (UVa Supersonic Combustion Facility, Configuration E) consisted of a Mach 2 nozzle, an isolator with fuel injectors, a test section with a cavity flame holder and optical access, and an extender. Standard test conditions comprised total temperature 1200 K, total pressure 300 kPa, local equivalence ratio near 0.4, and local Mach number near 0.6. OH PLIF data was also collected for a case with reduced total temperature and another with reduced equivalence ratio. OH and CH2O were excited in separate experiments with light sheets at 283.55 nm and 352.48 nm, respectively. A light sheet of approximate thickness 25 ?m illuminated the stream-wise midplane. This plane was imaged for 120 mm downstream of the backward-facing step. The intensified camera system imaged OH with magnification 1.97, a square 6.67 mm field of view, and in-plane resolution of 39 ?m. The smallest observed OH structures observed were approximately 100 ?m wide. The CH2O PLIF image signal was much weaker; the smallest observed structures were approximately 200 ?m wide. Composite fluorescence images were computed for the observed area.

Geipel, Clayton M.↗

OH PLIF Visualization of a Premixed Ethylene-fueled Dual-Mode Scramjet Combustor

Hydroxyl radical (OH) planar induced laser fluorescence (PLIF) measurements have been performed in a small-scale scramjet combustor at the University of Virginia Aerospace Research Laboratory at nominal simulated Mach 5 enthalpy. OH lines were carefully chosen to have fluorescent signal that is independent of pressure and temperature but linear with mole fraction. The OH PLIF signal was imaged in planes orthogonal to and parallel to the freestream flow at different equivalence ratios. Flameout limits were tested and identified. Instantaneous planar images were recorded and analyzed to compare the results with width increased dual-pump enhanced coherent anti-Stokes Raman spectroscopy (WIDECARS) measurements in the same facility and large eddy simulation/Reynolds average Navier-Stokes (LES/RANS) numerical simulation. The flame angle was found to be approximately 10 degrees for several different conditions, which is in agreement with numerical predictions and measurements using WIDECARS. Finally, a comparison between NO PLIF non-combustion cases and OH PLIF combustion cases is provided: the comparison reveals that the dominant effect of flame propagation is freestream turbulence rather than heat release and concentration gradients.

Cantu, Luca M. L.↗

Nitric Oxide PLIF Visualization of Simulated Fuel-Air Mixing in a Dual-Mode Scramjet

Nitric oxide (NO) planar induced laser fluorescence (PLIF) measurements have been performed in a small scale scramjet combustor at the University of Virginia Aerospace Research Laboratory at nominal simulated Mach 5 flight. A mixture of NO and N2 was injected at the upstream end of the inlet isolator as a surrogate for ethylene fuel, and the mixing of this fuel simulant was studied with and without a shock train. The shock train was produced by an air throttle, which simulated the blockage effects of combustion downstream of the cavity flame holder. NO PLIF signal was imaged in a plane orthogonal to the freestream at the leading edge of the cavity. Instantaneous planar images were recorded and analyzed to identify the most uniform cases, which were achieved by varying the location of the fuel injection and shock train. This method was used to screen different possible fueling configurations to provide optimized test conditions for follow-on combustion measurements using ethylene fuel. A theoretical study of the selected NO rotational transitions was performed to obtain a LIF signal that is linear with NO mole fraction and approximately independent of pressure and temperature.

Cantu, Luca M. L.↗

Development of a Premixed Combustion Capability for Scramjet Combustion Experiments

Hypersonic air-breathing engines rely on scramjet combustion processes, which involve high speed, compressible, and highly turbulent flows. The combustion environment and the turbulent flames at the heart of these engines are difficult to simulate and study in the laboratory under well controlled conditions. Typically, wind-tunnel testing is performed that more closely approximates engine testing rather than a careful investigation of the underlying physics that drives the combustion process. The experiments described in this paper, along with companion data sets being developed separately, aim to isolate the chemical kinetic effects from the fuel-air mixing process in a dual-mode scramjet combustion environment. A unique fuel injection approach is taken that produces a nearly uniform fuel-air mixture at the entrance to the combustor. This approach relies on the precombustion shock train upstream of the dual-mode scramjet combustor. A stable ethylene flame anchored on a cavity flameholder with a uniformly mixed combustor inflow has been achieved in these experiments allowing numerous companion studies involving coherent anti-Stokes Raman scattering (CARS), particle image velocimetry (PIV), and planar laser induced fluorescence (PLIF) to be performed.

Rockwell, Robert D.↗

OH PLIF Visualization of the UVa Supersonic Combustion Experiment: Configuration A

Hydroxyl radical (OH) planar laser-induced fluorescence (PLIF) measurements were performed in the University of Virginia s dual-mode scramjet experiment. The test section was set up in configuration A, which includes a Mach 2 nozzle, combustor, and extender section. Hydrogen fuel was injected through an unswept compression ramp at two different equivalence ratios. Through the translation of the optical system and the use of two separate camera views, the entire optical range of the combustor was accessed. Single-shot, average, and standard deviation images of the OH PLIF signal are presented at several streamwise locations. The results show the development of a highly turbulent flame structure and provide an experimental database to be used for numerical model assessment.

Johansen, Craig T.↗