Search NASA⌕ Search

Engineering topics

Rod, Kenton

Publications and source records attributed to Rod, Kenton.

867 records · Page 49

Effect of chemical and physical heterogeneities on colloid-facilitated cesium transport

A set of column experiments was conducted to investigate the chemical and physical heterogeneity effect on colloid facilitated transport under slow pore velocity conditions. Pore velocities were kept below 100 cm d-1 for all experiments. Glass beads were packed into columns establishing four different conditions: 1) homogeneous, 2) mixed physical heterogeneity, 3) sequentially layered physical heterogeneity, and 4) chemical heterogeneity. The homogeneous column was packed with glass beads (diameter 500-600 µm), and physical heterogeneities were created by sequential layering or mixing two sizes of glass bead (500-600 µm and 300-400 µm). A chemical heterogeneity was created using 25% of the glass beads coated with hydrophobic molecules (1H-1H-2H-2H-perfluorooctyltrichlorosilane) mixed with 75% pristine glass beads (all 500-600 µm). Input solution with 0.5 mM CsI and 50 mg L-1 colloids (1-µm diameter SiO2) was pulsed into columns under saturated conditions. The physical heterogeneity in the packed glass beads retarded the transport of colloids compared to homogeneous (R = 25.0), but showed only slight differences between sequentially layered (R = 60.7) and mixed heterogeneity(R = 62.4). The column with the chemical, hydrophobic/hydrophilic, heterogeneity removed most of the colloids from the input solution. All column conditions stripped Cs from colloids onto the column matrix of packed glass beads.

Colloid-facilitated transport, cesium, physical he↗

Hexavalent chromium sensor for real-time In situ measurement of ground water contamination - 15433

Hexavalent chromium (Cr{sup 6+}) is a contaminant of concern at multiple Department of Energy (DOE) and industrial sites across the United States. It is used in stainless steel production, textile dyes, tanning, wood preservation, and in conversion coatings. It was used at DOE sites, such as the Hanford Nuclear Reservation in Washington state, in the form sodium dichromate (Na{sub 2}Cr{sub 2}O{sub 7}) to inhibit corrosion. This has resulted in the release of chromate (CrO{sub 4}{sup 2-}) to groundwater. Chromate is anionic and is readily transported with ground water through the subsurface to receptors such as river biota at Hanford, and in some regions to potable water wells. To improve Cr{sup 6+} groundwater plume monitoring while reducing monitoring cost, a cable-deployed, submersible sensor was developed for direct measurements of Cr{sup 6+} in natural groundwater. With a diameter of 3.8 cm (1.5 inch) the sensor could be deployed in 5 cm (2 inch) diameter screened wells. The sensor uses ultra violet (UV) photo-spectroscopy to measure Cr{sup 6+} at concentrations as low as 5 to 10 μg L{sup -1} (as hexavalent chromium, Cr{sup +6}) in natural water. Turbidity, caused by colloidal material suspended in natural water, can interfere with the chromate measurement but was automatically compensated within the instrument. Because the instrument had some temperature sensitivity, a correction was also applied based on in situ temperature measurements in the sensor. The sensor has been tested in the laboratory and was deployed to the field with encouraging results. Laboratory calibrations consistently yielded concentration measurements that correlate well with standard analytical methods (r{sup 2} = 0.99). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗