Search NASA⌕ Search

Engineering topics

Rodd, Nicholas L

Publications and source records attributed to Rodd, Nicholas L.

Energy Distribution of the Galactic Center Excess’s Sources

The Galactic Center Excess (GCE) may yet herald the discovery of annihilating dark matter. Weighing against that conclusion are analyses showing evidence for dim point sources within the spatial structure of the emission. Because of technical limitations these analyses are purely spatial with all spectral information that could disentangle the excess from astrophysical backgrounds discarded. Here, we demonstrate that a neural network simulation-based inference approach can jointly analyze the spatial and spectra data. The addition is profound: energy information drives the putative point sources to be significantly dimmer, indicating either the GCE is truly diffuse in nature or made of an exceptionally large number of sources. Quantitatively, for our best fit background model, the excess is essentially consistent with Poisson emission as predicted by dark matter. If due to point sources, our median prediction is O(10^{5}) sources, or more than 35 000 at 90% confidence-both orders of magnitude larger than the hundreds preferred by earlier point-source analyses of the GCE, although variations allowed by background systematics could reduce the required number of sources by roughly an order of magnitude.

List, Florian↗

Magnets are Weber Bar Gravitational Wave Detectors

When a gravitational wave (GW) passes through a dc magnetic field, it couples to the conducting wires carrying the currents which generate the magnetic field, causing them to oscillate at the GW frequency. The oscillating currents then generate an ac component through which the GW can be detected-thus forming a resonant mass detector or a nagnetic Weber bar. We quantify this claim and demonstrate that magnets can have exceptional sensitivity to GWs over a frequency range demarcated by the mechanical and electromagnetic resonant frequencies of the system; indeed, we outline why a magnetic readout strategy can be considered an optimal Weber bar design. The concept is applicable to a broad class of magnets, but can be particularly well exploited by the powerful magnets being deployed in search of axion dark matter, for example, by DMRadio and ADMX-EFR. Explicitly, we demonstrate that the MRI magnet that is being deployed for ADMX-EFR can achieve a broadband GW strain sensitivity of ∼10^{-20}/sqrt[Hz] from a few kHz to about 10 MHz, with a peak sensitivity down to ∼10^{-22}/sqrt[Hz] at a kHz exploiting a mechanical resonance.

Domcke, Valerie↗