Search NASA⌕ Search

Engineering topics

Rodriguez, J.I.

Publications and source records attributed to Rodriguez, J.I..

The Effect of Transfer Line Length and Heat Rejection Temperature Distribution on the Thales Linear Pulse Tube (LPT) Cryocoolers

Four Thales LPT9310 and four Thales LPT9510 commercial off-the-shelf (COTS) cryocoolers were parametrically performance tested. The LPT9310 coolers had transfer lines of various lengths while the LPT9510 coolers all had the same transfer line geometry. The LPT9510 test results revealed unit-tounit thermodynamic performance variation, quantified the effect of compressor temperature on thermodynamic performance and quantified the heat flow distribution between the compressor and expander as a function of their temperature distribution. The LPT9310 test results revealed the optimal drive frequency as a function of transfer line length, quantified the effect of heat rejection temperature distribution on thermodynamic performance and enabled the development and verification of a thermodynamic performance prediction tool that accounted for cold tip temperature, heat lift, heat rejection temperature and transfer line length.

Rodriguez, J.I.↗

Characterization Testing of Lockheed Martin Micro1-2 Cryocoolers Optimized for 220 K Environment

The Mapping Imaging Spectrometer for Europa (MISE) Instrument on the Europa Clipper mission has baselined a Lockheed Martin high-power Micro1-2 pulse tube cryocooler operating at 135 Hz with a 220 K heat rejection temperature. This paper describes the testing and results of two Lockheed Martin Micro1-2 coolers optimized for these conditions. The thermal performance of the microcoolers was measured in vacuum for heat reject temperatures between 220 and 230 K. The coolers were operated with input powers ranging from 5 W to 40 W and drive frequency between 125 Hz and 145 Hz. The optimal drive frequency was strongly dependent on heat reject temperature. In addition, the exported forces and torques of the coolers were measured at 300 K heat rejection for input powers ranging from 5 W to 60 W and drive frequency between 120 Hz and 160 Hz. The exported forces were dependent on both piston amplitude and drive frequency. Moreover, the following were measured on one of the coolers: DC and AC magnetic fields at various locations, the off-state conductance of the pulse tube, and the effect of inclination angle of the pulse tube relative to gravity on the performance of the cooler. Finally, one of the coolers was subjected to random vibration testing.

Rodriguez, J.I.↗

Low Temperature Characterization of Mechanical Isolators for Cryocoolers

For spacecraft applications requiring active refrigeration, exported vibrations from a cryocooler can be a concern. One approach to minimizing the vibrations transmitted from cryocoolers to the spacecraft is to mount them on mechanical isolators. Many commercial off-theshelf (COTS) mechanical isolators exist and have been characterized at room temperature for ground applications. However, the space environment presents challenges that complicate the selection process. Mechanical isolators in space must be made of materials that can withstand harsh radiation environments. Future instruments, such as the Mapping Imaging Spectrometer for Europa (MISE) on the Europa Clipper mission, are considering operating cryocoolers with low heat rejection temperatures and mounting them on mechanical isolators. However, the performance of many simple, traditional mechanical isolators at low temperatures is unknown. This paper describes the testing and results of various mechanical isolators able to withstand harsh radiation between 200 K and 300 K. The transmissibility of wire rope type isolators showed very little temperature dependence up to ~500 Hz. On the other hand, the transmissibility of silicone gel was strongly dependent on temperature as the material had an abrupt change in stiffness near its solid-solid phase change. Custom titanium flexures showed the most promise with a maximum transmissibility of 0.04 above 500 Hz and no expected temperature dependence.

Rodriguez, J.I.↗

Maturation and Status of the Lockheed Martin Micro1-2 Cryocooler

This paper describes the maturation and status of the Lockheed Martin “High Power” Micro1-2 pulse tube cryocooler. This cryocooler, which was qualified to technology readiness level 6 in 2014, is the baseline cooler for the Jet Propulsion Laboratory (JPL) Mapping Imaging Spectrometer for Europa (MISE) instrument aboard the Europa Clipper mission, and the Johns Hopkins University Applied Physics Laboratory (JHU-APL) Gamma Ray and Neutron Spectrometer (GRNS) aboard the planned Psyche asteroid mission. This paper will describe enhancements to the cryocooler made for the MISE program, specifically modifications to maximize the cooler efficiency at low heat rejection temperature (220 K) and to increase the operating frequency. The paper will also describe minor modifications for the GRNS program, specifically modification of the coldfinger for low thermal emissivity and the addition of a cold tip interface tab. Finally, the paper will describe modifications made for operation with 150 K heat rejection temperature and 35 K cold tip temperature for the Deep Space Cooling System (DSCS) project with Iris Technology.

Frohling, K.↗