Search NASA⌕ Search

Engineering topics

Rogers, D. C.

Publications and source records attributed to Rogers, D. C..

Analysis of Ice Nucleating Aerosol Measurements during SUCCESS: April, May 1996

This section describes our research activities during year three of this effort. In the second year, preliminary archive data sets were submitted to the SUCCESS archive. After additional analyses, final versions were prepared and submitted. These are included on the SUCCESS CD-ROM data editions that were recently released by NASA Ames. Over the range of temperature and supersaturation conditions of our measurements (15 to -40 C, and from ice saturation to approximately 15% water supersaturation), IN concentrations ranged from less than 0.1 to approximately 500 per liter, being generally greater at colder temperatures and higher supersaturations. To estimate the potential of aircraft exhaust as a source of IN, we examined data from six days of the field project when the DC-8 was following closely behind other humidity conditions of our measurements. In April 1997, a microphysical workshop was convened at NCAR to select cases for in depth analyses and to address questions about the consistency of cloud ice crystal measurements (size distributions and mass concentrations) and aerosol size distributions. We attended this meeting and contributed to the discussions. A particular concern was identified in the CN measurements. On the DC-8, CN measurements were obtained by four different investigator groups, using commercially available instrumentation. The DC-8 SUCCESS CN data showed long periods where the measurements were in substantial agreement, but there were also periods with large discrepancies. Several possible factors were identified that could help explain these discrepancies, including minimum detectable particle size, response at reduced pressures, and location of sample inlet on the aircraft.

Rogers, D. C.↗

Measurements of Ice Nucleating Aerosols in the Upper Troposphere and Lower Stratosphere

Our major accomplishments during Year 1 were: Development of aerosol and crystal collection techniques. Development of single-particle chemical characterization techniques. Modification of system design for DC-8 and initial testing. Our major accomplishments during Year 2 were: Completion of system design and proof-of-concept experiments. Participation in SUCCESS mission. Reporting of theoretical and laboratory findings in the scientific literature. Reporting of initial SUCCESS results at scientific meetings. Our major accomplishments during Year 3 were: Data reduction and submission of all SUCCESS data to the archive. Participation in SUCCESS data comparison workshops. Reporting of SUCCESS results at the AEAP Meeting. Organization of CN counter intercomparison workshop. Preparation of three manuscripts submitted to the GRL SUCCESS Special Issue.

Kreidenweis, S. M.↗

Laboratory Investigation of Direct Measurement of Ice Water Content, Ice Surface Area, and Effective Radius of Ice Crystals Using a Laser-Diffraction Instrument

The aircraft microphysics probe, PVM-100A, was tested in the Colorado State University dynamic cloud chamber to establish its ability to measure ice water content (IWC), PSA, and Re in ice clouds. Its response was compared to other means of measuring those ice-cloud parameters that included using FSSP-100 and 230-X 1-D optical probes for ice-crystal concentrations, a film-loop microscope for ice-crystal habits and dimensions, and an in-situ microscope for determining ice-crystal orientation. Intercomparisons were made in ice clouds containing ice crystals ranging in size from about 10 microns to 150 microns diameter, and ice crystals with plate, columnar, dendritic, and spherical shapes. It was not possible to determine conclusively that the PVM accurately measures IWC, PSA, and Re of ice crystals, because heat from the PVM evaporated in part the crystals in its vicinity in the chamber thus affecting its measurements. Similarities in the operating principle of the FSSP and PVM, and a comparison between Re measured by both instruments, suggest, however, that the PVM can make those measurements. The resolution limit of the PVM for IWC measurements was found to be on the order of 0.001 g/cubic m. Algorithms for correcting IWC measured by FSSP and PVM were developed.

Gerber, H.↗

Measurements of natural ice nuclei with a continuous flow diffusion chamber

A description is given of a continuous flow diffusion chamber technique for measuring the atmospheric concentrations of natural C-F nuclei. It is noted that the same device can also measure deposition nuclei; these two modes can thus be separated and compared. The laminar flow characteristics allow the temperature and supersaturation to be calculated with a high degree of precision and confidence. The method avoids the problems of a supporting substrate and of concentrating the sample into a small volume (as for membrane filters). The present measurements of natural ice nucleus concentrations at +1 percent water supersaturation are found to be comparable to research aircraft measurements of ice crystal concentrations in winter cap clouds over Elk Mountain, Wyoming (Vali et al., 1982).

Rogers, D. C.↗

Ice crystal and ice nucleus measurements in cap clouds

Ice nucleation in cap clouds over a mountain in Wyoming was examined with airborne instrumentation. Crosswind and wind parallel passes were made through the clouds, with data being taken on the ice crystal concentrations and sizes. A total of 141 penetrations of 26 separate days in temperatures ranging from -7 to -24 C were performed. Subsequent measurements were also made 100 km away from the mountain. The ice crystal concentrations measured showed good correlation with the ice nucleus content in winter time, midcontinental air masses in Wyoming. Further studies are recommended to determine if the variations in the ice nucleus population are the cause of the variability if ice crystal content.

Vali, G.↗

Contribution to CCN Workshop report from University of Wyoming group

The group's CCN counter is described. It is a static, horizontal, parallel plate thermal gradient diffusion chamber. Examples of the application of the CCN are presented and include the CCN spectra measured during the winter of 1978-79 near Elk Mountain, Wyoming. Comparisons of droplet concentrations derived from upwind CCN spectra are covered.

Rogers, D. C.↗

Comparing dry aerosol size measurements

Two instruments were used to size dry aerosols for the CCN experiments: the Naval Research Laboratory (NRL) instrument which uses an electrical mobility analyzer to separate the aerosol size fractions and a diffusion chamber to grow and count the particles and the University of Wyoming (WYO) aerosol monitoring system. Measurements from these two systems were usually found to be in agreement during the CCN Workshop. Two examples are presented to compare aerosol size distribution measurements of the two instruments: experiment 8 (monodisperse NaCl) and experiment 27 (polydisperse AgI). Differential (dN/dR) and cumulative plots are shown for both instruments for experiment 8 and experiment 27; also shown are Aitken particle measurements for comparison.

Rogers, D. C.↗

Vacuum-assisted impregnation of materials

Vacuum-assisted liquid-impregnation treatment for silicon-carbide-reinforced carbon-carbon systems improves resistance of silicon-carbide coating to attack by oxygen at elevated temperatures. Porosity reduction treatment might also be applied to sintering silicon-carbide bodies to increase their density and to make them more resistant to hot gases for use in jet engines.

Rogers, D. C.↗

Material development aspects of an oxidation protection system for a reinforced carbon-carbon composite

The paper describes the procedures which led to selection of a diffusion-coated siliconized oxidation-resistant reinforced carbon-carbon composite as a candidate for use in the leading edge structure of the Space Shuttle for the purpose of providing thermal protection. Materials were evaluated on the basis of oxidation-inhibitor performance, strength properties, and fabricability. Compounds of titanium, tantalum, zirconium, silicon, hafnium, aluminum, and boron were compounded with the reinforced carbon-carbon material in two different processing techniques to discover an oxidation-inhibited system which provided multicycle protection at temperatures up to 4000 F. Details of the manufacture and testing of the reinforced carbon-carbon composites are provided.

Rogers, D. C.↗

Formation mechanism of a silicon carbide coating for a reinforced carbon-carbon composite

Results are presented for a study to determine the mechanisms involved in a high-temperature pack cementation process which provides a silicon carbide coating on a carbon-carbon composite. The process and materials used are physically and chemically analyzed. Possible reactions are evaluated using the results of these analytical data. The coating is believed to develop in two stages. The first is a liquid controlled phase process in which silicon carbide is formed due to reactions between molten silicon metal and the carbon. The second stage is a vapor transport controlled reaction in which silicon vapors react with the carbon. There is very little volume change associated with the coating process. The original thickness changes by less than 0.7%. This indicates that the coating process is one of reactive penetration. The coating thickness can be increased or decreased by varying the furnace cycle process time and/or temperature to provide a wide range of coating thicknesses.

Rogers, D. C.↗

Oxidation resistant carbon-carbon composite for Space Shuttle application.

An oxidation resistant carbon-carbon composite has been developed for use on the NASA Space Shuttle Orbiter Vehicle which can function on the high temperature surfaces to satisfy the 100 mission reuse capability requirement. This paper describes the design requirements, materials and processes developed, and the successful testing of simulated full-scale prototype hardware. Materials considerations are illustrated, including strength and oxidation testing, along with physical property determinations, characterizing the material over the predicted temperature range of use.

Rogers, D. C.↗