Search NASA⌕ Search

Engineering topics

Rogly, R.

Publications and source records attributed to Rogly, R..

Measurements of the charge ratio and polarization of cosmic-ray muons with the Super-Kamiokande detector

We present the results of the charge ratio (𝑅) and polarization (𝑃$^{𝜇}_{0}$) measurements using decay electron events collected between September 2008 and June 2022 with the Super-Kamiokande detector. Because of its underground location and long operation, we are able to perform high-precision measurements by accumulating cosmic-ray muons. We measured the muon charge ratio to be 𝑅 = 1.32 ± 0.02⁢(stat +syst) at 𝐸 𝜇 ⁢cos⁡𝜃 Zenith = 0.7$^{+0.3}_{−0.2}$ TeV, where 𝐸 𝜇 is the muon energy and 𝜃 Zenith is the zenith angle of incoming cosmic-ray muons. This result is consistent with the Honda flux model while indicating a tension with the 𝜋⁢𝐾 model of 1.9⁢𝜎. We also measured the muon polarization at the production location to be 𝑃$^{𝜇}_{0}$ = 0.52 ± 0.02 (stat+syst) at the muon momentum of 0.9$^{+0.6}_{−0.1}$ TeV/𝑐 at the surface of the mountain; this also suggests a tension with the Honda flux model of 1.5⁢𝜎. This is the most precise measurement ever to experimentally determine the cosmic-ray muon polarization near 1 TeV/𝑐. These measurement results are useful to improve atmospheric neutrino simulations.

Atmospheric neutrino oscillations↗

Second gadolinium loading to Super-Kamiokande

The first loading of gadolinium (Gd) into Super-Kamiokande in 2020 was successful, and the neutron capture efficiency on Gd reached 50%. To further increase the Gd neutron capture efficiency to 75%, 26.1 tons of Gd 2 (SO 4 ) 3 ∙ 8H 2 O was additionally loaded into Super-Kamiokande (SK) from May 31 to July 4, 2022. As the amount of loaded Gd 2 (SO 4 ) 3 ∙ 8H 2 O was doubled compared to the first loading, the capacity of the powder dissolving system was doubled. We also developed new batches of gadolinium sulfate with even further reduced radioactive impurities. In addition, a more efficient screening method was devised and implemented to evaluate these new batches of Gd 2 (SO 4 ) 3 ∙ 8H 2 O. Following the second loading, the Gd concentration in SK was measured to be 333.5 ± 2.5 ppm via an Atomic Absorption Spectrometer (AAS). From the mean neutron capture time constant of neutrons from an Am/Be calibration source, the Gd concentration was independently measured to be 332.7 ± 6.8(sys.) ± 1.1(stat.) ppm, consistent with the AAS result. Furthermore, during the loading the Gd concentration was monitored continually using the capture time constant of each spallation neutron produced by cosmic-ray muons, and the final neutron capture efficiency was shown to become 1.5 times higher than that of the first loaded phase, as expected.

Gadolinium↗