Search NASA⌕ Search

Engineering topics

Rokni, Sayed H.

Publications and source records attributed to Rokni, Sayed H..

Monte Carlo simulation of shielding designs for a cabinet form factor preclinical MV–energy photon FLASH radiotherapy system

Purpose: A preclinical MV-energy photon FLASH radiotherapy system is being designed at Stanford and SLAC National Accelerator Laboratory. Because of the higher energy and dose rate compared to conventional kV-energy photon laboratory-scale irradiators, adequate shielding in a stand-alone cabinet form factor is more challenging to achieve. We present a Monte Carlo simulation of multilayered shielding for a compact self-shielding system without the need for a radiation therapy vault. Methods: A multilayered shielding approach using multiple alternating layers of high-Z and low-Z materials is applied to the self-shielded cabinet to effectively mitigate the secondary radiation produced and to allow the device to be housed in a Controlled Radiation Area outside of a radiation vault. The multilayered shielding approach takes advantage of the properties of high-Z and low-Z radiation shielding materials such as density, cross-section, atomic number of the shielding elements, and products of radiation interactions within each layer. The Monte Carlo radiation transport code, FLUKA, is used to simulate the total effective dose produced by the operation. Results: The multilayered shielding designs proposed and simulated produced effective dose rates significantly lower than monolayer designs with the same total material thickness at the regulatory boundary; this is accomplished through the manipulation of the locations where secondary radiation is produced and reactions due to material properties such as neutron back reflection in hydrogen. Borated polyethylene at 5 wt% significantly increased the shielding performance as compared to regular polyethylene, with the magnitude of the reduction depending upon the order of the shielding material. Conclusions: The multilayered shielding provides a path for shielding preclinical FLASH systems that deliver MV-energy bremsstrahlung photons. Furthermore, this approach promises to be more efficient with respect to the shielding material mass and space claim as compared to shielded vaults typically required for clinical radiation therapy with MV photons.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Skyshine from an Accelerator Facility: Dependence on Distance and Angle

Neutron skyshine from Linac Coherent Light Source II 4 GeV electron beam operation at SLAC National Accelerator Laboratory can contribute to prompt radiation exposure to the public at distances far beyond the accelerator tunnel housing. One of the shielding design requirements at SLAC is that the annual dose to a member of the public is no more than 0.05 mSv y -1 . Our work uses Monte Carlo code FLUKA to simulate the generation of neutrons from 4 GeVelectron beam losses on a thick copper target inside a generalized geometry of the Linac Coherent Light Source II Beam Transport Hall accelerator tunnel section. The effective dose from neutron skyshine was characterized as a function of both distance from the tunnel wall (up to 1 km away) and angle relative to the beam direction (between 0° and 180°). Furthermore, this new methodology for evaluating neutron skyshine dose is applicable to high-energy GeV-range electron accelerator facilities both at SLAC and elsewhere.

43 PARTICLE ACCELERATORS↗

Radiation Protection Around High-intensity Laser Interactions with Solid Targets

Interaction of a high-intensity optical laser with a solid target can generate an ionizing radiation hazard in the form of high-energy "hot" electrons and bremsstrahlung, resulting from hot electrons interacting with the target itself and the surrounding target chamber. Previous studies have characterized the bremsstrahlung dose yields generated by such interactions for lasers in the range of 10 17 to 10 22 W cm -2 using particle-in-cell code EPOCH and Monte Carlo code FLUKA. Electron measurements based on a depth-dose approach are presented for two laser intensities, which indicate a Maxwellian distribution is more suitable for estimating the hot electrons' energy distribution. Also, transmission factors for the resulting bremsstrahlung for common shielding materials are calculated with FLUKA, and shielding tenth-value-layer thicknesses are also derived. In combination with the bremsstrahlung dose yield, the tenth-value layers provide radiation protection programs the means to evaluate radiation hazards and design shielding for high-intensity laser facilities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Bremsstrahlung Dose Yield for High-Intensity Short-Pulse Laser–Solid Experiments

A bremsstrahlung source term has been developed by the Radiation Protection (RP) group at SLAC National Accelerator Laboratory for high-intensity short-pulse laser–solid experiments between 10 17 and 10 22 W cm –2 . This source term couples the particle-in-cell plasma code EPOCH and the radiation transport code FLUKA to estimate the bremsstrahlung dose yield from laser–solid interactions. EPOCH characterizes the energy distribution, angular distribution, and laser-to-electron conversion efficiency of the hot electrons from laser–solid interactions, and FLUKA utilizes this hot electron source term to calculate a bremsstrahlung dose yield (mSv per J of laser energy on target). The goal of this paper is to provide RP guidelines and hazard analysis for high-intensity laser facilities. In conclusion, a comparison of the calculated bremsstrahlung dose yields to radiation measurement data is also made.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation Protection Aspects in the Design of the Linac Coherent Light Source II

Since 2009, the Linac Coherent Light Source at the SLAC National Accelerator Laboratory produces ultra-fast, ultra-bright X-ray pulses with which atoms and molecules can be visualized as they move, hence revealing the mechanics of chemistry and revolutionizing the research in fields ranging from biology to energy sciences. LCLS-II is a sister vicinal facility with new features that will be soon constructed to address the surging demand of FEL beams. In this paper we summarize the radiation protection scheme for LCLS-II and we describe diverse challenges and the adopted solutions. In particular we present the access modes of LCLS-II that allow simultaneous operation with LCLS. Monte Carlo simulations have been used to design beam components like stoppers and to define the thickness of walls. Also, by carefully analyzing the contributors to the residual dose, the shielding of the main dumps has been optimized to meet engineering constraints while allowing access after short cool down.

43 PARTICLE ACCELERATORS↗

Monte Carlo Studies for the Radiation Shielding Design of LCLS-II

Intensive Monte Carlo simulations performed with state-of-the-art computation codes are applied to the radiation shielding design of LCLS-II, which will be the extension of Linac Coherent Light Source (LCLS) at SLAC and will use the middle one-third of SLAC two-mile Linac. This paper describes the Monte Carlo studies of the first and last system where electron beams are involved, namely the LCLS-II Injector and the X-ray Transport and Diagnostics System (XTOD).

43 PARTICLE ACCELERATORS↗

Top-Off Injection and Higher Currents at the Stanford Synchrotron Radiation Lightsource

The Stanford Synchrotron Radiation Lightsource (SSRL) at the SLAC National Accelerator Laboratory is a 234 m circumference storage ring for 3 GeV electrons with its synchrotron radiation serving currently 13 beamlines with about 27 experimental stations. It operated for long time with 100 mA peak current provided by usually three injections per day. In July 2009, the maximum beam current was raised to 200 mA. Over the period from June 2009 to March 2010, Top-Off operation started at every beamline. Top-Off, i.e., the injection of electrons into the storage ring with injection stoppers open, is necessary for SSRL to reach its design current of 500 mA. In the future, the maximal power of the injection current will also soon be raised from currently 1.5 W to 5 W. The Radiation Protection Department at SLAC worked with SSRL on the specifications for the safety systems for operation with Top-Off injection and higher beam currents.

43 PARTICLE ACCELERATORS↗