Search NASASearch

Engineering topics

Rollbuhler, R. J.

Publications and source records attributed to Rollbuhler, R. J..

Experimental studies on effervescent atomizers with wide spray angles

An experimental investigation was conducted to examine the operating and spray characteristics of two internal-mixing twin-fluid atomizers that were designed to produce effervescent atomization at low air/liquid mass ratios (ALR's). These two experimental atomizers ejected the two phase flow so as to produce a wide spray angle. One atomizer was a plain orifice design that used a four-hole exit orifice which divided and turned the two phase flow just prior to ejection. The other atomizer, called the conical sheet atomizer, ejected the two phase flow through an annular passage in such a way as to form a hollow cone spray. The atomizer operating parameters varied during this investigation were the air/liquid mass ratio, atomizer operating pressure, and, in the case of the conical sheet atomizer, the exit gap width. Studies of spray characteristics included measurements of the spray Sauter mean diameter (SMD), drop size distribution, and, for the conical sheet atomizer, circumferential distribution of the liquid mass within the spray. For both atomizers it was found that SMD decreases with an increase in either ALR or operating pressure. The effect of ALR on SMD diminishes as the value of ALR increases. For the conical sheet atomizer, when operating at low values of pressure and ALR, SMD increases with increase in gap width, but the influence of gap width on SMD diminishes with an increase in either pressure or ALR. At the highest operating pressure of the conical sheet atomizer (552 kPa), SMD is independent of gap width at all ALR's. For both atomizers, changes in operating pressure and ALR have little effect on the distribution of drop sizes in the spray.

Whitlow, J. D.

Lewis Pressurized, Fluidized-Bed Combustion Program. Data and Calculated Results

A 200 kilowatt (thermal), pressurized, fluidized bed (PFB) reactor and research test facility were designed, constructed, and operated. The facility was established to assess and evaluate the effect of PFB hot gas effluent on aircraft turbine engine materials that may have applications in stationary powerplant turbogenerators. The facility was intended for research and development work and was designed to operate over a wide range of conditions. These conditions included the type and rate of consumption of fuel (e.g., coal) and sulfur reacting sorbent material: the ratio of feed fuel to sorbent material; the ratio of feed fuel to combustion airflow; the depth of the fluidized reaction bed; the temperature and pressure in the reaction bed; and the type of test unit that was exposed to the combustion exhaust gases.

Rollbuhler, R. J.

Lewis Research Center's coal-fired, pressurized, fluidized-bed reactor test facility

A 200-kilowatt-thermal, pressurized, fluidized-bed (PFB) reactor, research test facility was designed, constructed, and operated as part of a NASA-funded project to assess and evaluate the effect of PFB hot-gas effluent on aircraft turbine engine materials that might have applications in stationary-power-plant turbogenerators. Some of the techniques and components developed for this PFB system are described. One of the more important items was the development of a two-in-one, gas-solids separator that removed 95+ percent of the solids in 1600 F to 1900 F gases. Another was a coal and sorbent feed and mixing system for injecting the fuel into the pressurized combustor. Also important were the controls and data-acquisition systems that enabled one person to operate the entire facility. The solid, liquid, and gas sub-systems all had problems that were solved over the 2-year operating time of the facility, which culminated in a 400-hour, hot-gas, turbine test.

Kobak, J. A.

Improved PFB operations - 400-hour turbine test results

The paper deals with a 400-hr small turbine test in the effluent of a pressurized fluidized bed (PFB) at an average temperature of 770 C, an average relative gas velocity of 300 m/sec, and average solid loadings of 200 ppm. Consideration is given to combustion parameters and operating procedure as well as to the turbine system and turbine test operating procedures. Emphasis is placed on erosion/corrosion results.

Rollbuhler, R. J.

Factors affecting cleanup of exhaust gases from a pressurized, fluidized-bed coal combustor

The cleanup of effluent gases from the fluidized-bed combustion of coal is examined. Testing conditions include the type and feed rate of the coal and the sulfur sorbent, the coal-sorbent ratio, the coal-combustion air ratio, the depth of the reactor fluidizing bed, and the technique used to physically remove fly ash from the reactor effluent gases. Tests reveal that the particulate loading matter in the effluent gases is a function not only of the reactor-bed surface gas velocity, but also of the type of coal being burnt and the time the bed is operating. At least 95 percent of the fly ash particules in the effluent gas are removed by using a gas-solids separator under controlled operating conditions. Gaseous pollutants in the effluent (nitrogen and sulfur oxides) are held within the proposed Federal limits by controlling the reactor operating conditions and the type and quantity of sorbent material.

Rollbuhler, R. J.

Improved PFB operations: 400-hour turbine test results

A pressurized fluidized bed (PFB) coal-burning reactor was used to provide hot effluent gases for operation of a small gas turbine. Preliminary tests determined the optimum operating conditions that would result in minimum bed particle carryover in the combustion gases. Solids were removed from the gases before they could be transported into the test turbine by use of a modified two stage cyclone separator. Design changes and refined operation procedures resulted in a significant decrease in particle carryover, from 2800 to 93 ppm (1.5 to 0.05 grains/std cu ft), with minimal drop in gas temperature and pressure. The achievement of stable burn conditions and low solids loadings made possible a 400 hr test of small superalloy rotor, 15 cm (6 in.) in diameter, operating in the effluent. Blades removed and examined metallographically after 200 hr exhibited accelerated oxidation over most of the blade surface, with subsurface alumina penetration to 20 micron m. After 400 hours, average erosion loss was about 25 micron m (1 mil). Sulfide particles, indicating hot corrosion, were present in depletion zones, and their presence corresponded in general to the areas of adherent solids deposit. Sulfidation appears to be a materials problem equal in importance to erosion.

Rollbuhler, R. J.

Effluent characterization from a conical pressurized fluid bed

To obtain useable corrosion and erosion results it was necessary to have data with several levels of particulate matter in the hot gases. One level of particulate loading was as low as possible so that ideally no erosion and only corrosion occurred. A conical fluidized bed was used to obtain some degree of filtration through the top of the bed which would not be highly fluidized. This would minimize the filtration required for the hot gases or conversely the amount of particulate matter in the hot gases after a given level of filtration by cyclones and/or filters. The data obtained during testing characterized the effluent from the bed at different test conditions. A range of bed heights, coal flows, air flows, limestone flows, and pressure are represented. These tests were made to determine the best operating conditions prior to using the bed to determine erosion and corrosion rates of typical turbine blade materials.

Priem, R. J.

Effluent characterization from a conical pressurized fluid bed

An important factor regarding the use of a pressurized coal burning fluidized bed (PFB) providing gases for driving a gas turbine is the turbine blade lifetime. However, very little data are currently available to predict erosion and corrosion rates produced by the effluent from a PFB. To assess the potential of alloys developed for aeronautical applications to resist this environment it was decided to build a coal burning fluidized bed that could be employed to measure erosion and corrosion rates. Tests were conducted with a conical fluidized bed to obtain some degree of filtration through the top of the bed. A description is presented of the data obtained in the first 138 hours of testing to characterize the effluent from the bed under different test conditions. The considered tests had been made to determine the best operating conditions prior to using the bed for a determination of the erosion and corrosion rates of typical turbine blade materials.

Priem, R. J.

Centaur boost pump turbine icing investigation

An investigation was conducted to determine if ice formation in the Centaur vehicle liquid oxygen boost pump turbine could prevent rotation of the pump and whether or not this phenomenon could have been the failure mechanism for the Titan/Centaur vehicle TC-1. The investigation consisted of a series of tests done in the LeRC Space Power Chamber Facility to evaluate evaporative cooling behavior patterns in a turbine as a function of the quantity of water trapped in the turbine and as a function of the vehicle ascent pressure profile. It was found that evaporative freezing of water in the turbine housing, due to rapid depressurization within the turbine during vehicle ascent, could result in the formation of ice that would block the turbine and prevent rotation of the boost pump. But for such icing conditions to exist it would be necessary to have significant quantities of water in the turbine and/or its components, and the turbine housing temperature would have to be colder than 40 F at vehicle liftoff.

Rollbuhler, R. J.