Search NASA⌕ Search

Engineering topics

Romano, F.

Publications and source records attributed to Romano, F..

Overview of Liquid-Metal PFC R&D at the University of Illinois Urbana-Champaign

The design and implementation of future flowing liquid-lithium plasma-facing components (LLPFCs) will be dependent on several factors. Of course, one of the most important is the need to be able to deal with high heat fluxes incident on the surface of the LLPFCs, but there are also several other important liquid-metal behaviors that have been identified for their critical impact on the feasibility of a LLPFC. One of these is the ability to constantly wet 100% of the plasma-facing component area and the best way to achieve that. Another key point is knowing and understanding the erosion and corrosion of the surfaces subject to a flowing liquid-lithium system and the ability for hydrogen and helium uptake by the system. The Center for Plasma Material Interactions (CPMI) has been tasked with looking at these various issues. The Mock-up Entry module for EAST device was used to investigate wetting and erosion effects and to design a suitable distribution and collection system with a liquid-lithium loop. The vapor shielding effects of lithium on the surface were also modeled and studied. A model coupling CRANE, an open-source global reaction network solver, and Zapdos, a plasma transport solver, is being developed to better understand the dynamics of the vapor cloud. Experiments on the Magnum-PSI at the Dutch Institute for Fundamental Energy Research have been carried out to study the vapor shielding effect and obtain experimental benchmarks to verify the model. Also, initial experiments using the Hybrid Illinois Device for Research and Applications have been performed to understand the pumping effects of lithium on helium. Experiments with a drop of liquid lithium (~100 mg) into a helium plasma have shown the ability of lithium to take out the cold recycling helium gas as well as hydrogen and oxygen impurity gases. The improvement in plasma performance was significant, and further understanding of this effect will have impacts on how future LLPFCs will be designed. Further investigation into the exact mechanism for helium pumping by lithium needs to be performed in the future. Finally, this paper presents a summary of the results obtained at the CPMI.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Report on G4-Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group

Geant4 is a Monte Carlo code extensively used in medical physics for a wide range of applications, such as dosimetry, micro- and nanodosimetry, imaging, radiation protection, and nuclear medicine. Geant4 is continuously evolving, so it is crucial to have a system that benchmarks this Monte Carlo code for medical physics against reference data and to perform regression testing. In this work, to respond to these needs, we developed G4-Med, a benchmarking and regression testing system of Geant4 for medical physics. G4-Med currently includes 18 tests. They range from the benchmarking of fundamental physics quantities to the testing of Monte Carlo simulation setups typical of medical physics applications. Both electromagnetic and hadronic physics processes and models within the prebuilt Geant4 physics lists are tested. The tests included in G4-Med are executed on the CERN computing infrastructure via the use of the geant-val web application, developed at CERN for Geant4 testing. The physical observables can be compared to reference data for benchmarking and to results of previous Geant4 versions for regression testing purposes. This paper describes the tests included in G4-Med and shows the results derived from the benchmarking of Geant4 10.5 against reference data.

60 APPLIED LIFE SCIENCES↗

Recent developments in Geant4

Geant4 is a software toolkit for the simulation of the passage of particles through matter. It is used by a large number of experiments and projects in a variety of application domains, including high energy physics, astrophysics and space science, medical physics and radiation protection. Over the past several years, major changes have been made to the toolkit in order to accommodate the needs of these user communities, and to efficiently exploit the growth of computing power made available by advances in technology. The adaptation of Geant4 to multithreading, advances in physics, detector modeling and visualization, extensions to the toolkit, including biasing and reverse Monte Carlo, and tools for physics and release validation are discussed here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EAQUATE: An International Experiment for Hyper-Spectral Atmospheric Sounding Validation

The international experiment called EAQUATE (European AQUA Thermodynamic Experiment) was held in September 2004 in Italy and the United Kingdom to demonstrate certain ground-based and airborne systems useful for validating hyperspectral satellite sounding observations. A range of flights over land and marine surfaces were conducted to coincide with overpasses of the AIRS instrument on the EOS Aqua platform. Direct radiance evaluation of AIRS using NAST-I and SHIS has shown excellent agreement. Comparisons of level 2 retrievals of temperature and water vapor from AIRS and NAST-I validated against high quality lidar and drop sonde data show that the 1K/1km and 10%/1km requirements for temperature and water vapor (respectively) are generally being met. The EAQUATE campaign has proven the need for synergistic measurements from a range of observing systems for satellite cal/val and has paved the way for future cal/val activities in support of IASI on the European Metop platform and CrIS on the US NPP/NPOESS platform.

Taylor, J. P.↗