Search NASA⌕ Search

Engineering topics

Rosas, Rogelio

Publications and source records attributed to Rosas, Rogelio.

Thermal Design of the Thermal Infrared Spectrometer (TIRS) Instrument on PREFIRE

The Polar Radiant Energy in the Far-Infrared Experiment (PREFIRE) consists of two 6U CubeSats that each host a Thermal Infrared Spectrometer (TIRS) instrument. The CubeSats are scheduled for launch in March and October of 2023. The purpose of the TIRS instrument is to make spectrally resolved measurements of the Earth’s thermal radiation from the top of the atmosphere. PREFIRE will document, for the first time, variability in spectral fluxes from 4 to 54 microns on hourly to seasonal timescales. The primary mission is 12 months in a polar orbit with inclination of 82 to 98 at altitudes between 450 km and 650 km. The TIRS instrument is an Offner spectrometer that uses a thermopile detector array and a Schwarzchild telescope. In addition, there is a scan mirror which is periodically actuated for calibration. The instrument concept of operation is to collect radiation emitted towards zenith in a nadir sounding orientation with periodic internal and space calibrations. The TIRS thermal control architecture consists of entirely passive elements. The instrument requires all elements be maintained between 0 C and 50 C during operation for the duration of the mission. An overview of the overall thermal control design approach is presented.

Andrade, Andres↗

Multi-Angle Imager for Aerosols Thermal Control System

The Multi-Angle Imager for Aerosols (MAIA) Thermal Control System is a NASA funded instrument that will collect data to help characterize airborne particulate matter over a number of population centers across the globe using multi-angle spectropolarimetric imagery. The data collected by MAIA will facilitate assessments of the impacts of different types of particulate matter on adverse health outcomes. MAIA is a hosted payload meant to operate in a near-circular sun-synchronous polar orbit, with a mean altitude between 600 km and 850 km. The nominal on-orbit mission design lifetime is three years. Temperature control of the MAIA instrument is accomplished with a combination of passive radiators and heaters. The focal plane module (FPM) is cooled to ≤ 235K with a disc shaped radiator that faces the anti-sun side of the sun-synchronous orbit. The temperature of the MAIA cameras and associated electronics is controlled with a cylindrical shaped radiator that projects a near constant area in the nadir direction as the cameras rotate. A noteworthy feature of the MAIA thermal control system design is the novel, low cost, rotationally articulating thermal strap used to transfer heat from the FPMs to their associated FPM Radiator. The strap spans one of the axes of rotation, sweeping out an arc of approximately 60° as the instrument operates. A prototype of the articulating thermal strap was life tested to 260,000 cycles with no signs of significant degradation. An overview of the MAIA thermal control system baseline design is presented, with focus on its novel aspects, including life testing of the prototype articulating thermal strap. In addition, a discussion of the considerations involved in designing a thermal control system for a hosted instrument is provided.

Rosas, Rogelio↗

A Focus on Cryogenic Engineering for the Primordial Inflation Polarization Explorer (PIPER) Mission

Cryogenic engineering involves design and modification of equipment that is used under boiling point of nitrogen which is 77 K. The focus of this paper will be on the design of hardware for cryogenic use and a retrofit that was done to the main laboratory cryostat used to test flight components for the Primordial Inflation Polarization Explorer balloon-borne mission. Data from prior tests showed that there was a superfluid helium leak and a total disassemble of the cryostat was conducted in order to localize and fix the leak. To improve efficiency new fill tubes and clamps with modifications were added to the helium tank. Upon removal of the tank, corrosion was found on the flange face that connects to the helium cold plate and therefore had to be fully replaced and copper plated to prevent future corrosion. Indium seals were also replaced for the four fill tubes, a helium level sensor, and the nitrogen and helium tanks. Four additional shielded twisted pairs of cryogenic wire and a wire harness for the Superconducting Quantum Interference Devices (SQUIDs) were added. Finally, there was also design work done for multiple pieces that went inside the cryostat and a separate probe used to test the SQUIDs. Upon successful completion of the cryostat upgrade, tests were run to check the effectiveness and stability of the upgrades. The post-retrofit tests showed minor leaks were still present and due to this, superfluidity has still not been attained. As such there could still be a possibility of a superfluid leak appearing in the future. Regardless, the copper plating on the helium tank has elongated the need to service it by three to five years.

Rosas, Rogelio↗