WE-AB-BRB-04: A Novel Monolithic Silicon 2D Detector Array for Use in Stereotactic Applications

Purpose: To assess the capability of a novel 2D monolithic silicon detector array in measuring stereotactic photon fields. Methods: The silicon array detector used in this work, named Magic Plate-512 (MP512), is a thin monolithic silicon wafer (52 × 52 × 0.47 mm{sup 3}) with 512 ion-implanted diodes (0.5 × 0.5 mm{sup 2}). Adjacent pixels are spaced evenly with 2 mm pitch, covering a maximum detection area 46 mm wide. Its fast, FPGA based read-out system is synchronised with the linac to allow readout of all pixels pulse-by-pulse. A clinical SABR lung plan (consisting of 9 single segment beams, 6MV) was measured with the array at 1.5 cm depth in a solid water phantom (100 cm SSD). The typical field size was in the range of 3 × 3 cm{sup 2} to 4 × 4 cm{sup 2}. Each beam was delivered at perpendicular incidence to the detector plane so as to avoid the need for angular dependence corrections. The fields were measured under the same conditions using Gafchromic EBT3 film for comparison. The film was scanned at 72 dpi resolution, with the red channel data used for analysis. Results: Average gamma passing rates of (92.3 ± 1.8) % for 2%/2mm criteria, and (86.6 ± 2.3) % for 1%/2mm criteria were achieved for MP512, using EBT3 film as the reference distribution. The detector array was able to accurately measure the full-width-at-half-maximum (FWHM), to within (0.77 ± 0.01) mm accuracy when compared to film. The penumbral widths (80%-20%) were measured to within (0.30 ± 0.01) mm accuracy to film. Conclusion: The MP512 is a feasible option for measurement of stereotactic photon fields, with its high density of detection points making it useful for small field applications. The prototype array has demonstrated merit; in the future the development of a larger array detection area would be beneficial for clinical applications.

60 APPLIED LIFE SCIENCES↗

Formation of laser-induced periodic surface structures on fused silica upon multiple cross-polarized double-femtosecond-laser-pulse irradiation sequences

The formation of laser-induced periodic surface structures (LIPSS) upon irradiation of fused silica with multiple irradiation sequences consisting of five Ti:sapphire femtosecond (fs) laser pulse pairs (150 fs, 800 nm) is studied experimentally. A Michelson interferometer is used to generate near-equal-energy double-pulse sequences with a temporal pulse delay from -20 to +20 ps between the cross-polarized individual fs-laser pulses ({approx}0.2 ps resolution). The results of multiple double-pulse irradiation sequences are characterized by means of Scanning Electron and Scanning Force Microscopy. Specifically in the sub-ps delay domain striking differences in the surface morphologies can be observed, indicating the importance of the laser-induced free-electron plasma in the conduction band of the solids for the formation of LIPSS.

36 MATERIALS SCIENCE↗

Laser-induced modification of transparent crystals and glasses

We analyse the processes taking place in transparent crystals and glasses irradiated by ultrashort laser pulses in the regimes typical of various applications in optoelectronics and photonics. We consider some phenomena, which have been previously described by the authors within the different model representations: charging of the dielectric surface due to electron photoemission resulting in a Coulomb explosion; crater shaping by using an adaptive control of the laser pulse shape; optimisation of the waveguide writing in materials strongly resistant to laser-induced compaction under ordinary irradiation conditions. The developed models and analysis of the processes relying on these models include the elements of the solid-state physics, plasma physics, thermodynamics, theory of elasticity and plasticity. Some important experimental observations which require explanations and adequate description are summarised. (photonics and nanotechnology)

36 MATERIALS SCIENCE↗

Potential High Resolution Dosimeters For MRT

Microbeam Radiation Therapy (MRT) uses highly collimated, quasi-parallel arrays of X-ray microbeams of 50-600 keV, produced by 2nd and 3rd generation synchrotron sources, such as the National Synchrotron Light Source (NSLS) in the U.S., and the European Synchrotron Radiation Facility (ESRF) in France, respectively. High dose rates are necessary to deliver therapeutic doses in microscopic volumes, to avoid spreading of the microbeams by cardiosynchronous movement of the tissues. A small beam divergence and a filtered white beam spectrum in the energy range between 30 and 250 keV results in the advantage of steep dose gradients with a sharper penumbra than that produced in conventional radiotherapy. MRT research over the past 20 years has allowed a vast number of results from preclinical trials on different animal models, including mice, rats, piglets and rabbits. Microbeams in the range between 10 and 100 micron width show an unprecedented sparing of normal radiosensitive tissues as well as preferential damage to malignant tumor tissues. Typically, MRT uses arrays of narrow ({approx}25-100 micron-wide) microplanar beams separated by wider (100-400 microns centre-to-centre, c-t-c) microplanar spaces. We note that thicker microbeams of 0.1-0.68 mm used by investigators at the NSLS are still called microbeams, although some invesigators in the community prefer to call them minibeams. This report, however, limits it discussion to 25-100 {mu}m microbeams. Peak entrance doses of several hundreds of Gy are surprisingly well tolerated by normal tissues. High resolution dosimetry has been developed over the last two decades, but typical dose ranges are adapted to dose delivery in conventional Radiation Therapy (RT). Spatial resolution in the sub-millimetric range has been achieved, which is currently required for quality assurance measurements in Gamma-knife RT. Most typical commercially available detectors are not suitable for MRT applications at a dose rate of 16000 Gy/s, micron resolution and a dose range over several orders of magnitude. This paper will give an overview of all dosimeters tested in the past at the ESRF with their advantages and drawbacks. These detectors comprise: Ionization chambers, Alanine Dosimeters, MOSFET detectors, Gafchromic registered films, Radiochromic polymers, TLDs, Polymer gels, Fluorescent Nuclear Track Detectors (Al{sub 2}O{sub 3}:C, Mg single crystal detectors), OSL detectors and Floating Gate-based dosimetry system. The aim of such a comparison shall help with a decision on which of these approaches is most suitable for high resolution dose measurements in MRT. The principle of these detectors will be presented including a comparison for some dosimeters exposed with the same irradiation geometry, namely a 1x1 cm{sup 5} field size with microbeam exposures at the surface, 0.1 cm and 1 cm in depth of a PMMA phantom. For these test exposures, the most relevant irradiation parameters for future clinical trials have been chosen: 50 micron FWHM and 400 micron c-t-c distance. The experimental data are compared with Monte Carlo calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combinatorial investigation of (Ti{sub 1-x}Nb{sub x}){sub 2}AlC

We have synthesized thin films of (Ti{sub 1-x}Nb{sub x}){sub 2}AlC by combinatorial method on TiC (111) seed layers grown on c-axis sapphire (Al{sub 2}O{sub 3}) substrates at 900 deg. C using magnetron sputter. X-ray diffraction showed the films to be c-axis oriented and epitaxial, and films contained a minor secondary phase of (Ti,Nb)C, irrespective of stoichiometry. Most notably, Raman spectroscopy suggest a sizable increase in the elastic modulus in the Nb-rich region as compared to either of the end members.

36 MATERIALS SCIENCE↗

Femtosecond laser-induced periodic surface structures revisited: A comparative study on ZnO

Laser-induced periodic surface structures (LIPSS) (ripples) with different spatial characteristics have been observed after irradiation of single-crystalline zinc oxide surfaces with multiple linearly polarized femtosecond pulses (150-200 fs, 800 nm) in air. For normal incident laser radiation, low spatial frequency LIPSS (LSFL) with a period (630-730 nm) close to the wavelength and an orientation perpendicular to the laser polarization have been found in the fluence range between {approx}0.7 and {approx}0.8 J/cm{sup 2} and predominantly for pulse numbers up to N=100. For lower fluences (0.5-0.7 J/cm{sup 2}), a sharp transition from the LSFL features toward the formation of high spatial frequency LIPSS (HSFL) appears at any given pulse number below N=100. The HSFL are always parallel to the LSFL, exhibit spatial periods between 200 and 280 nm, and completely substitute the LSFL for pulse numbers N>100. Additionally, the influence of the angle of incidence has been studied experimentally for both LIPSS types revealing a different behavior. Experimental evidence for surface scattered second harmonic generation is presented in the regime of HSFL formation. Moreover, we will show that the HSFL structures on ZnO surfaces can be fully explained by an extension of the existing LIPSS theories if the photoexcitation of the dielectric material (affecting its transient optical properties) is considered in the frame of a simple Drude model along with the second harmonic generation at the irradiated surface. Based on our analysis, the current models of femtosecond laser-induced LIPSS are revisited and an explanation is proposed why HSFL are observed predominantly in the subpicosecond range for below band-gap excitation of dielectrics and semiconductors.

36 MATERIALS SCIENCE↗

Dynamics of femtosecond laser induced voidlike structures in fused silica

Focused ultrafast laser irradiation of fused silica usually induces a spatially modulated refractive index variation in the bulk material. Strong energy concentration leads to the localized formation of a lower-density cavitylike depressed structure surrounded by compacted matter. We report on applying time-resolved phase contrast microscopy to investigate the timescale of the void formation. We indicate a temporal behavior consistent with shock wave generation and subsequent rarefaction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗