Rositano, S.

Publications and source records attributed to Rositano, S..

Measuring mandibular motions

Mandibular motion along three axes is measured by three motion transducers on floating yoke that rests against mandible. System includes electronics to provide variety of outputs for data display and processing. Head frame is strapped to test subject's skull to provide fixed point of reference for transducers.

Dimeff, J.↗

Recent NASA contributions to biomedical telemetry

The present work reviews technological progress over the past five years in the field of long-term telemetric monitoring of physiological parameters during space flight. Emphasis is placed on those developments that have direct application to animal or human use on earth. An effort was made in these recent developments to free subjects from encumbering wires: a swallowable telemetry capsule for monitoring body temperature and a wristwatch transmitter connected to EKG leads were two of the devices developed.

Sandler, H.↗

Advance techniques for monitoring human tolerance to positive Gz accelerations

Tolerance to positive g accelerations was measured in ten normal male subjects using both standard and advanced techniques. In addition to routine electrocardiogram, heart rate, respiratory rate, and infrared television, monitoring techniques during acceleration exposure included measurement of peripheral vision loss, noninvasive temporal, brachial, and/or radial arterial blood flow, and automatic measurement of indirect systolic and diastolic blood pressure at 60-sec intervals. Although brachial and radial arterial flow measurements reflected significant cardiovascular changes during and after acceleration, they were inconsistent indices of the onset of grayout or blackout. Temporal arterial blood flow, however, showed a high correlation with subjective peripheral light loss.

Pelligra, R.↗

Advance techniques for monitoring human tolerance to +Gz accelerations.

Standard techniques for monitoring the acceleration-stressed human subject have been augmented by measuring (1) temporal, brachial and/or radial arterial blood flow, and (2) indirect systolic and diastolic blood pressure at 60-sec intervals. Results show that the response of blood pressure to positive accelerations is complex and dependent on an interplay of hydrostatic forces, diminishing venous return, redistribution of blood, and other poorly defined compensatory reflexes.

Pelligra, R.↗