Temporal light modulation: A phantom array visibility measure

At temporal light modulation (TLM) frequencies between 80 Hz and 20 000 Hz observers may perceive a series of repeated images called the phantom array effect (PAE) when they move their eyes in large saccades across a modulating light source or across a scene lit by the modulating light source. To date, there is no well-established measure for quantifying PAE visibility, but there is growing awareness of the need for one among design professionals and sensitive populations. This paper documents a new measure, the phantom array visibility measure (PAVM), which is based on the results of recent human factors experiments. The measure follows the mathematical underpinning used by the flicker visibility measure and the stroboscopic visibility measure, where the time-domain TLM waveform is converted into its Fourier frequency components; each component is evaluated through a threshold curve of modulation depth, then summed through an equation employing a Minkowski exponent. This scales the PAVM so that a value of 1 indicates a waveform at a threshold visibility in the conditions of the underlying experiment.

Tan, J.↗

Experimental validation of color rendition specification criteria based on ANSI/IES TM-30-18

An experiment was conducted to examine color preference specification criteria. Twenty-five participants each evaluated 90 lighting scenes in a room filled with objects. The lighting scenes included nine chromaticity groups, each with 10 systematically-varied color rendition conditions designed to meet or not meet previously proposed color preference specification criteria using ANSI/IES TM-30-18 Rf, Rcs,h1, and Rg. The color rendition conditions did not meet the criterion for none, one, two, or all three of these measures. Participants, who chromatically adapted to each chromaticity group, rated the objects’ color appearance on eight-point scales for saturated-dull, normal-shifted, and like-dislike (preference), as well as a binary for acceptable or unacceptable. The findings corroborate past work, but also indicate that color preference criteria could be adjusted slightly to improve performance, with Tier A having Rf = 78, Rg = 95, and -1% = Rcs,h1 = 15%, Tier B having Rf = 74, Rg = 92, and -7% = Rcs,h1 = 19%, and Tier C having Rf = 70, Rg = 89, -12% = Rcs,h1 = 23%. A companion regression analysis shows models based on Rf, Rg, and Rcs,h1 were superior in predicting color preference compared to those using other measures of color rendition.

Royer, Michael P.↗

Human perceptions of colour rendition vary with average fidelity, average gamut, and gamut shape

An experiment was conducted to evaluate how subjective impressions of color quality vary with changes in average fidelity, average gamut, and gamut shape (which considers the specific hues that are saturated or desaturated). Twenty-eight participants each evaluated 26 lighting conditions—created using four, seven-channel, tunable LED luminaires—in a 3.1 m by 3.7 m room filled with objects selected to cover a range of hue, saturation, and lightness. IES TM-30 fidelity index (Rf) values ranged from 64 to 93, IES TM-30 gamut index (Rg¬) values from 79 to 117, and IES TM-30 Rcs,h1 values (a proxy for gamut shape) from -19% to 26%. All lighting conditions delivered the same nominal illuminance and chromaticity. Participants were asked to rate each condition on eight point semantic differential scales for saturated-dull, normal-shifted, and like-dislike. They were also asked one multiple choice question, classifying the condition as saturated, dull, normal, or shifted. The findings suggest that gamut shape is more important than average gamut for human preference, where reds play a more important role than other hues. Additionally, average fidelity alone is a poor predictor of human perceptions, although Rf was somewhat better than CIE Ra. The most preferred source had a CIE Ra value of 68, and 9 of the top 12 rated products had a CIE Ra value of 73 or less, which indicates that the commonly used criteria of CIE Ra ≥ 80 may be excluding a majority of preferred light sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗