Search NASA⌕ Search

Engineering topics

Rozeveld, Steve

Publications and source records attributed to Rozeveld, Steve.

Imaging 3D chemistry at 1 nm resolution with fused multi-modal electron tomography

Measuring the three-dimensional (3D) distribution of chemistry in nanoscale matter is a longstanding challenge for metrological science. The inelastic scattering events required for 3D chemical imaging are too rare, requiring high beam exposure that destroys the specimen before an experiment is completed. Even larger doses are required to achieve high resolution. Thus, chemical mapping in 3D has been unachievable except at lower resolution with the most radiation-hard materials. Here, high-resolution 3D chemical imaging is achieved near or below one-nanometer resolution in an Au-Fe 3 O 4 metamaterial within an organic ligand matrix, Co 3 O 4 -Mn 3 O 4 core-shell nanocrystals, and ZnS-Cu 0.64 S 0.36 nanomaterial using fused multi-modal electron tomography. Multi-modal data fusion enables high-resolution chemical tomography often with 99% less dose by linking information encoded within both elastic (HAADF) and inelastic (EDX/EELS) signals. We thus demonstrate that sub-nanometer 3D resolution of chemistry is measurable for a broad class of geometrically and compositionally complex materials.

36 MATERIALS SCIENCE↗

Measuring 3D Chemistry at 1 nm Resolution with Fused Multi-Modal Electron Tomography

Measuring the three-dimensional (3D) distribution of chemistry in nanoscale matter is a longstanding challenge for metrological science. The inelastic scattering events required for 3D chemical imaging are too rare, requiring high beam exposure that destroys the specimen before an experiment is completed. Even larger doses are required to achieve high resolution. Thus, chemical mapping in 3D has been unachievable except at lower resolution with the most radiation-hard materials. Here, high-resolution 3D chemical imaging is achieved near or below one-nanometer resolution in an Au-Fe3O4 metamaterial within an organic ligand matrix, Co3O4-Mn3O4 core-shell nanocrystals, and ZnS-Cu0.64S0.36 nanomaterial using fused multi-modal electron tomography. Multi-modal data fusion enables high-resolution chemical tomography often with 99% less dose by linking information encoded within both elastic (HAADF) and inelastic (EDX/EELS) signals. We thus demonstrate that sub-nanometer 3D resolution of chemistry is measurable for a broad class of geometrically and compositionally complex materials.

Schwartz, Jonathan↗

Exploring Functional Materials by Understanding Beam‐Sample Interactions

Abstract Ultra‐low‐dose electron diffraction is performed with a double metal cyanide catalyst (DMC) to understand how electron irradiation stimulates structural alterations in functional materials. The commonly fading diffraction patterns with dose accumulation depend on the irradiated area and the beam current even when below 50 femto Amperes. Heat generation is observed and modeled by statistical, inelastic scattering events to describe how phonon excitations modulate radiation hardness. Specifically, the characteristic 1/e‐decay of Bragg intensities from DMC is delayed from 6 to 30 eÅ −2 at room temperature, which is comparable to the effect of embedding radiation soft matter in ice. DMC's radiation hardness is enhanced by a latency dose that forms during a phase transformation. This unifying model predicts that a critical dose rate exists for any material that varies between 0.1 and 10 4 eÅ −2 s −1 because of a material dependent competition of heat generation and spread. It shows that Brillouin scattering causes time dependent perturbations in electron irradiated solids that trigger time‐temperature‐transformations on a time scale of nanoseconds to microseconds at room temperature, which is not included in traditional models describing the decay of Bragg intensities by radiolysis.

Kisielowski, Christian↗

Support Effect and Surface Reconstruction in In 2 O 3 / m- ZrO 2 Catalyzed CO 2 Hydrogenation

Here, we investigate the chemical and structural dynamics at the interface of In 2 O 3 /m-ZrO 2 and their consequences on the CO 2 hydrogenation reaction (CO 2 HR) under reaction conditions. While acting to enrich CO 2 , monoclinic zirconia (m-ZrO 2 ) was also found to serve as a chemical and structural modifier of In 2 O 3 that directly governs the outcome of the CO 2 HR. These modifying effects include the following: (1) Under reaction conditions (above 623 K), partially reduced In 2 O 3 , i.e., InO x (0 < x < 1.5), was found to migrate in and out of the subsurface of m-ZrO 2 in a semireversible manner, where m-ZrO 2 accommodates and stabilizes InO x by serving as a reservoir. The decreased concentration of surface InO x under elevated temperatures coincides with significantly decreased selectivity toward methanol and a sharp increase of the reverse water–gas shift reaction. The reconstruction-induced variation of InO x concentration appears to be one of the most important factors contributing to the altered catalytic performance of CO 2 HR at different reaction conditions. (2) The strong interactions and reactions between m-ZrO 2 and In 2 O 3 result in the activation of a pool of In–O bonds at the In 2 O 3 /m-ZrO 2 interface to form oxygen vacancies. On the other hand, the high dispersity of In 2 O 3 nanostructures onto m-ZrO 2 prevents their over-reduction under catalytically relevant conditions (up to 673 K), when bare In 2 O 3 is unavoidably reduced into the metallic phase (In 0 ). The relationship between the extent of reduction of In 2 O 3 and catalytic performance (CO 2 conversion, CH 3 OH selectivity, or yield of CH 3 OH) suggests the presence of an optimum coverage of surface InO x and oxygen vacancies under reaction conditions. The conventional model that links catalytic performance solely to the coverage of oxygen vacancies appears invalid in the present case. In situ analysis also allows the observation of surface reaction intermediates and their interconversions, including the reduction of CO 3 * into formate, a precursor for the formation of methanol and CO. The combinative ex situ and in situ study sheds light on the reaction mechanism of the CO 2 HR on In 2 O 3 /m-ZrO 2 -based catalysts. Our findings on the large-scale surface reconstructions, support effect, and the reaction mechanism of In 2 O 3 /m-ZrO 2 for CO 2 HR may apply to other related metal oxide catalyzed CO 2 reduction reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging atomic-scale chemistry from fused multi-modal electron microscopy

Efforts to map atomic-scale chemistry at low doses with minimal noise using electron microscopes are fundamentally limited by inelastic interactions. Here, fused multi-modal electron microscopy offers high signal-to-noise ratio (SNR) recovery of material chemistry at nano- and atomic-resolution by coupling correlated information encoded within both elastic scattering (high-angle annular dark-field (HAADF)) and inelastic spectroscopic signals (electron energy loss (EELS) or energy-dispersive x-ray (EDX)). By linking these simultaneously acquired signals, or modalities, the chemical distribution within nanomaterials can be imaged at significantly lower doses with existing detector hardware. In many cases, the dose requirements can be reduced by over one order of magnitude. This high SNR recovery of chemistry is tested against simulated and experimental atomic resolution data of heterogeneous nanomaterials.

36 MATERIALS SCIENCE↗

Discovering Hidden Material Properties of MgCl 2 at Atomic Resolution with Structured Temporal Electron Illumination of Picosecond Time Resolution

Abstract A combination of atomic resolution phase contrast electron microscopy and pulsed electron beams reveals pristine properties of MgCl 2 at 1.7 Å resolution that were previously masked by air and beam damage. Both the inter‐ and intra‐layer bonding in pristine MgCl 2 are weak, which leads to uncommonly large local orientation variations that characterize this Ziegler–Natta catalyst support. By delivering electrons with 1–10 ps pulses and ≈160 ps delay times, phonons induced by the electron irradiation in the material are allowed to dissipate before the subsequent delivery of the next electron packet, thus mitigating phonon accumulations. As a result, the total electron dose can be extended by a factor of 80–100 to study genuine material properties at atomic resolution without causing object alterations, which is more effective than reducing the sample temperature. In conditions of minimal damage, beam currents approach femtoamperes with dose rates around 1 eÅ −2 s −1 . Generally, the utilization of pulsed electron beams is introduced herein to access genuine material properties while minimizing beam damage.

Kisielowski, Christian↗

Performance of a Silicon-Drift Detector in 200kV TEM Environments

Silicon-drift detectors for energy-dispersive spectroscopy have gained increasing acceptance in the field principally because of their outstanding capabilities for high count-rate performance coupled with excellent resolution [1,2]. Improvements in design in the last few years have overcome some early disadvantages of the SDD in comparison to Si(Li) detectors, which have dominated the field for nearly 4 decades. Amongst these are detection efficiency in the low-energy regime, and a dropoff in detection efficiency at higher energies above 10keV. The former disadvantage has been largely overcome by generational design improvements to minimize the effective dead layer at the entrance window, so that present detectors provide better performance in the low-energy regime than Si(Li) detectors. In the latter case, higher energy peak detection performance has been improved by increasing the thickness of the detector. This is important primarily for the use of the SDD in a TEM environment, where very high count rates are not encountered due to the thin sample geometry. Also of importance for incorporation of an SDD into a TEM column is the lack of need for liquid nitrogen, since the SDD is chilled by a thermoelectric cooler. This is an advantage for SEM and microprobe operation also, but high-resolution TEMs (particularly aberration-corrected instruments) are more sensitive to vibration than SEMs or microprobes, so the much reduced form factor of an air-cooled SDD relative to a Si(Li) detector with a large LN2 dewar is desirable for use on the TEM. We have recently tested two Bruker C

200kV TEM↗