Resolving discrepancies in bang-time predictions for indirect-drive ICF experiments on the NIF: Insights from the Build-A-Hohlraum campaign

This study investigated discrepancies between measured and simulated x-ray drive in Indirect-Drive Inertial Confinement Fusion (ID-ICF) hohlraums at the National Ignition Facility. Despite advances in radiation-hydrodynamic simulations, a consistent “drive deficit” remains. Experimentally measured ID-ICF capsule bang-times are systematically 400–700 ps later than simulations predict. The Build-A-Hohlraum (BAH) campaign explored potential causes for this discrepancy by systematically varying hohlraum features, including laser entrance hole (LEH) windows, capsules, and gas fills. Overall, the agreement between simulated and experimental x-ray drive was found to be largely unaffected by these changes. The data allow us to exclude some hypotheses put forward to potentially explain the discrepancy. Errors in the local thermodynamic equilibrium (LTE) atomic modeling, errors in the modeling of LEH closure, and errors due to a lack of plasma species mix physics in simulations are shown to be inconsistent with our measurements. Instead, the data support the hypothesis that errors in NLTE emission modeling are a significant contributor to the discrepancy. X-ray emission in the 2–4 keV range is found to be approximately 30% lower than in simulations. This is accompanied by higher than predicted electron temperatures in the gold bubble region, pointing to errors in non-LTE modeling. Introducing an opacity multiplier of 0.87 on energy groups above 1.8 keV improves agreement with experimental data, reducing the bang-time discrepancy from 300 to 100 ps. These results underscore the need for refined NLTE opacity models to enhance the predictive power of hohlraum simulations.

Band emission↗

Ultra-fast single-crystal CVD diamonds in the particle time-of-flight (PTOF) detector for low yield burn-history measurements on the NIF (invited)

The Particle Time of Flight (PTOF) diagnostic is a chemical vapor deposition diamond-based detector and is the only diagnostic for measuring nuclear bang times of low yield (<1013) shots on the National Ignition Facility. Recently, a comprehensive study of detector impulse responses revealed certain detectors with very fast and consistent impulse responses with a rise time of <50 ps, enabling low yield burn history measurements. At the current standoff of 50 cm, this measurement is possible with fast 14 MeV neutrons from deuterium–tritium (DT) fusion plasmas. PTOF-inferred DT burn width numbers compare well with widths inferred from the gamma reaction history diagnostic on mid-yield (1013–1015) shots, where both systems are capable of making this measurement. These new capabilities could be extended to 2.5 MeV deuterium–deuterium neutrons from D plasmas and to even lower yield by reducing the detector standoff distance to 10 cm; a design for this is also presented.

42 ENGINEERING↗

Thermonuclear performance variability near ignition at the National Ignition Facility

We describe our current understanding of the variability and degradation mechanisms observed through a series of five indirectly driven inertial fusion implosions fielded at the National Ignition Facility in the fall of 2021, four of which attempted to reproduce the first experiment to achieve Lawson's criterion for ignition with a thermonuclear yield of 1.35 MJ on August 8, 2021. A large number of absolutely calibrated (imaging, time-resolved, and spectrally resolved) x-ray and neutron diagnostics are fielded on the NIF along multiple lines of sight for each experiment. This allows for a reconstruction of the DT fuel and ablator mix injected into the hotspot around peak burn. We show that nuclear yield variations are well reproduced by numerical modeling when the measured low mode asymmetries and mix mass are included. Furthermore, these observed perturbations during burn are linked to small variations in laser delivery and capsule defects. Stringent specifications are then set to achieve robust ignition with the implosion design studied in this paper.

Divol, L. (ORCID:0000000269699898)↗

Modeling ablator defects as a source of mix in high-performance implosions at the National Ignition Facility

Recent indirect drive inertial confinement fusion implosions on the National Ignition Facility (NIF) [Spaeth et al., Fusion Sci. Technol. 69, 25 (2016)] have crossed the threshold of ignition. However, performance has been variable due to several factors. One of the leading sources of variability is the quality of the high-density carbon (HDC) shells used as ablators in these experiments. In particular, these shells can have a number of defects that have been found to correlate with the appearance of ablator mix into the hot spot and a degradation in nuclear yield. These defects include pits on the ablator surface, voids in the ablator bulk, high-Z debris from the Hohlraum wall that adheres to the capsule surface, and finally the inherent granular micro-structure of the crystalline HDC itself. This paper summarizes high-resolution modeling of each of these mix sources in two recent high-performance NIF implosion experiments. The simulated impact from a range of individual capsule defects is found to be broadly consistent with the trends seen in experiment, lending credence to the modeling results and the details of the mixing process that they reveal. Interestingly, modeling of the micro-structure inherent to HDC shows that this perturbation source results in considerable mixing of the deuterium–tritium fuel with ablator material during the implosion. The reduction in fuel compression from this mix results in an approximately factor of two reduction in neutron yield in current implosions and emphasizes the importance of mitigating this significant performance degradation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of drive pulse shape on graded metal pushered single shell capsule implosions on the National Ignition Facility

Graded metal pushered single shells (PSS) are a viable alternative to low-Z capsules (Z is the atomic number) for indirect drive inertial confinement fusion implosions due to enhanced core tamping and radiation trapping, but they can be compromised by the pusher mixing with the fuel. We compare 2-shock and 3-shock laser pulses for Be/Cr PSS capsules filled with deuterium–tritium gas fuel at 6 mg/cc density. 1D radiation-hydrodynamic simulations predict higher core compression and, hence, ∼2× higher fusion yield for the 3-shock drive than for 2-shock. Nevertheless, we observe similar core ion temperatures and fusion yields for both drives. The implosion burn duration is 25% shorter and the core volume is ∼2.5× smaller for the 3-shock drive than for 2-shock, consistent with a higher compression. 1D LASNEX mix simulations using a buoyancy-drag model matching the measured yields also agree with the observed core sizes and burn durations and suggest ∼40% and ∼70% yield degradations for 2-shock and 3-shock drives due to hydrodynamic instabilities and atomic mix at the pusher–fuel interface. At the same time, 2D HYDRA simulations show that mid-mode (2–250) instability degradations are negligible for the 2-shock implosion (9%) and significant (45%) for 3-shock. Subtracting these from the 1D mix simulations, we infer similar degradations from high-mode instabilities and atomic mix for both drives. Due to its robustness to mid-mode instabilities, future pusher–gas mix studies will use the 2-shock drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of fusion reaction history in inertially confined burning plasmas

Direct evidence of inertially confined fusion ignition appears in the abrupt temperature increase and consequent rapid increase in the thermonuclear burn rate as seen in the reaction history. The Gamma Reaction History (GRH) and Gas Cherenkov Detector (GCD) diagnostics are γ-based Cherenkov detectors that provide high quality measurements of deuterium–tritium fusion γ ray production and are, thus, capable of monitoring the thermonuclear burn rate. Temporal shifts in both peak burn time and burn width have been observed during recent high-yield shots (yields greater than 1017 neutrons) and are essential diagnostic signatures of the ignition process. While the current GRH and GCD detectors are fast enough to sense the changes of reaction history due to alpha heating, they do not have enough dynamic range to capture the onset of alpha heating. The next generation of instrumentation, GRH-15m, is proposed to increase the yield-rate coverage to measure the onset of alpha-heating.

42 ENGINEERING↗

A 2–4 keV multilayer mirrored channel for the NIF Dante system

During inertial confinement fusion experiments at the National Ignition Facility (NIF), a capsule filled with deuterium and tritium (DT) gas, surrounded by a DT ice layer and a high-density carbon ablator, is driven to the temperature and densities required to initiate fusion. In the indirect method, 2 MJ of NIF laser light heats the inside of a gold hohlraum to a radiation temperature of 300 eV; thermal x rays from the hohlraum interior couple to the capsule and create a central hotspot at tens of millions degrees Kelvin and a density of 100–200 g/cm3. During the laser interaction with the gold wall, m-band x rays are produced at ∼2.5 keV; these can penetrate into the capsule and preheat the ablator and DT fuel. Preheat can impact instability growth rates in the ablation front and at the fuel–ablator interface. Monitoring the hohlraum x-ray spectrum throughout the implosion is, therefore, critical; for this purpose, a Multilayer Mirror (MLM) with flat response in the 2–4 keV range has been installed in the NIF 37° Dante calorimeter. Precision engineering and x-ray calibration of components mean the channel will report 2–4 keV spectral power with an uncertainty of ±8.7%.