High frequency fatigue testing of Udimet 700 at 1400 F
An investigation pertaining to the development of life prediction methods for materials subjected to high temperature creep/fatigue conditions is presented. High frequency (13.4 kHz) fatigue data were measured at 1400 F on specimens of the nickel-based alloy Udimet 700. Tests were conducted on the virgin material, as well as on specimens which had received prior exposures to high temperature, fatigue, and creep.