Volatile aldehyde emissions from “sub-ohm” vaping devices
"Sub-ohm" atomizers with reduced resistance can deliver more power than conventional electronic cigarettes. Typical battery outputs are 100 watts or more. These devices are particularly popular among young users, and can be a significant source of volatile carbonyls in the indoor environment. Emissions from next-generation sub-ohm vaping products were characterized by determining e-liquid consumption and volatile aldehydes emissions for several combinations of popular high-power configurations. Tests explored the effect of dilution air flow (air vent opening), puffing volume, and coil assembly configuration. The mass of liquid consumed per puff increased as the puff volume increased from 50 to 100 mL, then remained relatively constant for larger puff volumes up to 500 mL. This is likely due to mass transfer limitations at the wick and coil assembly, which reduced the vaporization rate at higher puff volumes. Carbonyl emission rates were systematically evaluated using a 0.15 Ω dual coil atomizer as a function of the puffing volume and dilution air flow, adjusted by setting the air vents to either 100% (fully open), 50%, 25%, or 0% (closed). The highest formaldehyde emissions were observed for the lowest puff volume (50 mL) when the vents 31 were closed (48 ng mg-1), opened at 25% (39 ng mg -1 ) and at 50% (32 ng mg -1 ).. By contrast, 50-mL puffs with 100% open vents, and puff volumes >100 mL for any vent aperture, generated formaldehyde yields of 20 ng mg -1 or lower, suggesting that a significant cooling effect resulted in limited carbonyl formation. Considering the effect of the coil resistance when operated at a voltage of 3.8 V, the amount of liquid evaporated per puff decreased as the resistance increased, in the order of 0.15 Ω > 0.25 Ω > 0.6 Ω consistent with decreasing aerosol temperatures measured at the mouthpiece. Three different configurations of 0.15 Ω coils (dual, quadruple and octuple) were evaluated, observing significant variability. No clear trend was found between carbonyl emission rates and coil resistance or configuration, with highest emissions corresponding to a 0.25 Ω dual coil atomizer. Carbonyl emission rates were compared with those determined using the same methodology for conventional e-cigarettes (lower power tank systems), observing overall lower yields for the sub-ohm devices.
Emissions from Heated Terpenoids Present in Vaporizable Cannabis Concentrates
Vaporizable cannabis concentrates (VCCs) consumed as a liquid (vaping) or a waxy solid (dabbing) are becoming increasingly popular. However, their associated emissions and impacts have not been fully described. Mixtures containing different proportions of 12 VCC terpenoids and high MW compounds were heated at 100-500 °C inside a room-sized chamber to simulate emissions. Terpenoids, thermal degradation byproducts, and ultrafine particles (UFPs) were quantified in the chamber air. Air samples contained over 50% of emitted monoterpenes and less than 40% of released sesquiterpenes and terpene alcohols. Eleven degradation byproducts were quantified, including acrolein (1.3-3.9 μg m -3 ) and methacrolein (2.0 μg m -3 ). A large amount of UFPs were released upon heating and remained airborne for at least 3 h. The mode diameter increased from 80 nm at 100 °C to 140 nm at 500 °C, and particles smaller than 250 nm contributed to 90% of PM 1.0 . Here, the presence of 0.5% of lignin, flavonoid, and triterpene additives in the heated mixtures resulted in a threefold increase in the particle formation rate and PM 1.0 concentration, suggesting that these high-molecular-weight compounds enhanced aerosol inception and growth. Predicted UFP emission rates in typical consumption scenarios (6 × 10 11 -2 × 10 13 # min -1 ) were higher than, or comparable with, other common indoor sources such as smoking and cooking.
Chemical changes in thirdhand smoke associated with remediation using an ozone generator
Ozonation is a common remediation approach to eliminate odors from mold, tobacco and fire damage in buildings. Little information exists to: 1) assess its effectiveness; 2) provide guidance on operation conditions; and 3) identify potential risks associated with the presence of indoor ozone and ozonation byproducts. The goal of this study is to evaluate chemical changes in thirdhand smoke (THS) aerosols induced by high levels of ozone, in comparison with THS aerosols aged under similar conditions in the absence of ozone. Samples representing different stages of smoke aging in the absence of ozone, including freshly emitted secondhand smoke (SHS) and THS, were collected inside an 18-m 3 room-sized chamber over a period of 42 h after six cigarettes were consumed. The experiments involved collection and analysis of gas phase species including volatile organic compounds (VOCs), volatile carbonyls, semivolatile organic compounds (SVOCs), and particulate matter. VOC analysis was carried out by gas chromatography/mass spectrometry with a thermal desorption inlet (TD-GC/MS), and volatile carbonyls were analyzed by on-line derivatization with dinitrophenylhydrazine (DNPH), followed by liquid chromatography with UV/VIS detection. SVOCs were extracted from XAD-coated denuders and Teflon-coated fiberglass filters in the absence of ozone. In those extracts, tobacco-specific nitrosamines (TSNAs) and other SVOCs were analyzed by gas chromatography with positive chemical ionization-triple quadrupole mass spectrometric detection (GC/PCI-QQQ-MS), and polycyclic aromatic hydrocarbons (PAHs) were quantified by gas chromatography with ion trap mass spectrometric detection (GC/IT-MS) in selected ion monitoring mode. Particulate matter concentration was determined gravimetrically. In a second experiment, a 300 mg h -1 commercial ozone generator was operated during 1 h, one day after smoke was generated, to evaluate the remediation of THS by ozonation. VOCs and volatile carbonyls were analyzed before and after ozonation. Extracts from fabrics that were exposed in the chamber before and after ozonation as surrogates for indoor furnishings were analyzed by GC/IT-MS, and aerosol size distribution was studied with a scanning mobility particle sizer. Ozone concentration was measured with a photometric detector. An estimated 175 mg ozone reacted with THS after 1 h of treatment, corresponding to 58% of the total O 3 released during that period. Fabric-bound nicotine was depleted after ozonation, and the surface concentration of PAHs adsorbed to fabric specimens decreased by an order of magnitude due to reaction with ozone, reaching pre-smoking levels. These results suggest that ozonation has the potential to remove harmful THS chemicals from indoor surfaces. However, gas phase concentrations of volatile carbonyls, including formaldehyde, acetaldehyde and acetone were higher immediately after ozonation. Ultrafine particles (UFP, in most cases with size <60 nm) were a major ozonation byproduct. UFP number concentrations peaked shortly after ozonation ended, and remained at higher-than background levels for several hours. Based on these results, minimum re-entry times after ozone treatment were predicted for different indoor scenarios. Clearly defining re-entry times can serve as a practical measure to prevent acute exposures to ozone and harmful ozonation byproducts after treatment. This study evaluated potential benefits and risks associated with THS remediation using ozone, providing insights into this technology.
Heated Tobacco Products: Volatile Emissions and Their Predicted Impact on Indoor Air Quality
This study characterized emissions from IQOS, a heated tobacco product promoted as a less harmful alternative to cigarettes. Consumable tobacco plugs were analyzed by headspace GC/MS to assess the influence of heating temperature on the emission profile. Yields of major chemical constituents increased from 4.1 mg per unit at 180 °C to 6.2 mg at 200 °C, and 10.5 mg at 220 °C. The Health Canada Intense smoking regime was used to operate IQOS in an environmental chamber, quantifying 33 volatile organic compounds in mainstream and sidestream emissions. Aldehydes, nitrogenated species, and aromatic species were found, along with other harmful and potentially harmful compounds. Compared with combustion cigarettes, IQOS yields were in most cases 1-2 orders of magnitude lower. However, yields were closer to, and sometimes higher than electronic cigarettes. Predicted users' daily average intake of benzene, formaldehyde, acetaldehyde and acrolein were 39 μg, 32 μg, 2.2 mg and 71 μg, respectively. Indoor air concentrations were estimated for commonly encountered scenarios, with acrolein levels of concern (over 0.35 μg m-3) derived from IQOS used in homes and public spaces. Heated tobacco products are shown to be a weaker indoor pollution source than conventional cigarettes, but their impacts are neither negligible nor yet fully understood.
De-pollution efficacy of photocatalytic roofing granules
Photocatalytic building surfaces can harness sunlight to reduce urban air pollution. The NO x abatement capacity of TiO 2 -coated granules used in roofing products was evaluated for commercial product development. A laboratory test chamber and ancillary setup were built following conditions prescribed by ISO Standard 22197-1. It was validated by exposing reference P25-coated aluminum plates to a 3 L min -1 air flow enriched in 1 ppm NO under UVA irradiation (360 nm, 11.5 W m -2 ). We characterized prototype granule-surfaced asphalt shingles and loose granules prepared with different TiO 2 loadings and post-treatment formulations. Tests performed at surface temperatures of 25 and 60 °C showed that NO x abatement was more effective at the higher temperature. Preliminary tests explored the use of 1 ppm NO 2 and of 1 ppm and 0.3 ppm NO/NO 2 mixtures. Specimens were aged in a laboratory accelerated weathering apparatus, and by exposure to the outdoor environment over periods that included dry and rainy seasons. Laboratory aging led to higher NO removal and NO 2 formation rates, and the same catalyst activation was observed after field exposure with frequent precipitation. However, exposure during the dry season reduced the performance. This inactivation was mitigated by cleaning the surface of field-exposed specimens. Doubling the TiO 2 loading led to a 50–150% increase in NO removal and NO x deposition rates. Finally, application of different post-treatment coatings decreased NO removal rates (21–35%) and NO x deposition rates (26–74%) with respect to untreated granules. The mass balance of nitrogenated species was assessed by extracting granules after UV exposure in a 1 ppm NO-enriched atmosphere.
Results of the California Healthy Homes Indoor Air Quality Study of 2011-2013: Impact of natural gas appliances on air pollutant concentrations
This study was conducted to assess the current impact of natural gas appliances on air quality in California homes. Data were collected via telephone interviews and measurements inside and outside of 352 homes. Passive samplers measured time-resolved CO and time-integrated NO X , NO 2 , formaldehyde, and acetaldehyde over ~6d periods in November 2011 - April 2012 and October 2012 - March 2013. The fraction of indoor NO X and NO 2 attributable to indoor sources was estimated. NO X , NO 2 and highest 1-h CO were higher in homes that cooked with gas and increased with amount of gas cooking. NO X and NO 2 were higher in homes with cooktop pilot burners, relative to gas cooking without pilots. Homes with a pilot burner on a floor or wall furnace had higher kitchen and bedroom NO X and NO 2 compared to homes without a furnace pilot. When scaled to account for varying home size and mixing volume, indoor-attributed bedroom and kitchen NO X and kitchen NO 2 were not higher in homes with wall or floor furnace pilot burners, though bedroom NO 2 was higher. In homes that cooked 4 h or more with gas, self-reported use of kitchen exhaust was associated with lower NO X , NO 2 and highest 1-h CO. Gas appliances were not associated with higher concentrations of formaldehyde or acetaldehyde.
Formaldehyde and acetaldehyde exposure mitigation in US residences: In-home measurements of ventilation control and source control
Measurements were taken in new US residences to assess the extent to which ventilation and source control can mitigate formaldehyde exposure. Increasing ventilation consistently lowered indoor formaldehyde concentrations. However, at a reference air exchange rate of 0.35 h -1 , increasing ventilation was up to 60% less effective than would be predicted if the emission rate were constant. This is consistent with formaldehyde emission rates decreasing as air concentrations increase, as observed in chamber studies. In contrast, measurements suggest acetaldehyde emission was independent of ventilation rate. To evaluate the effectiveness of source control, formaldehyde concentrations were measured in Leadership in Energy and Environmental Design (LEED) certified/Indoor airPLUS homes constructed with materials certified to have low emission rates of volatile organic compounds (VOC). At a reference air exchange rate of 0.35 h -1 , and adjusting for home age, temperature and relative humidity, formaldehyde concentrations in homes built with low-VOC materials were 42% lower on average than in reference new homes with conventional building materials. Without adjustment, concentrations were 27% lower in the low-VOC homes. The mean and standard deviation of formaldehyde concentration were 33 μg m-3 and 22 μg m -3 for low-VOC homes and 45 μg m -3 and 30 μg m -3 for conventional.
Investigation of Formaldehyde and Acetaldehyde Sampling Rate and Ozone Interference for Passive Deployment of Waters Sep-Pak XPoSure Samplers
Explore the source record for details and available documents.
Indoor Environmental Quality Benefits of Apartment Energy Retrofits
Explore the source record for details and available documents.
Ventilation Control of Volatile Organic Compounds in New U.S. Homes: Results of a Controlled Field Study in Nine Residential Units
In order to optimize strategies to remove airborne contaminants in residences, it is necessary to determine how contaminant concentrations respond to changes in the air exchange rate. The impact of air exchange rate on the indoor concentrations of 39 target volatile organic compounds (VOCs) was assessed by measuring air exchange rates and VOC concentrations at three ventilation settings in nine residences. Active sampling methods were used for VOC concentration measurements, and passive perfluorocarbon tracer gas emitters with active sampling were used to determine the overall air exchange rate corresponding to the VOC measurements at each ventilation setting. The concentration levels and emission rates of the target VOCs varied by as much as two orders of magnitude across sites. Aldehyde and terpene compounds were typically the chemical classes with highest concentrations, followed by alkanes, aromatics, and siloxanes. For each home, VOC concentrations tended to decrease as the air exchange rate was increased, however, measurement uncertainty was significant. The indoor concentration was inversely proportional to air exchange rate for most compounds. For a subset of compounds including formaldehyde, however, the indoor concentration exhibited a non-linear dependence on the timescale for air exchange.
Ventilation Control of Volatile Organic Compounds in New U.S. Homes: Results of a Controlled Field Study in Nine Residential Units
In order to optimize strategies to remove airborne contaminants in residences, it is necessary to determine how contaminant concentrations respond to changes in the air exchange rate. The impact of air exchange rate on the indoor concentrations of 39 target volatile organic compounds (VOCs) was assessed by measuring air exchange rates and VOC concentrations at three ventilation settings in nine residences. Active sampling methods were used for VOC concentration measurements, and passive perfluorocarbon tracer gas emitters with active sampling were used to determine the overall air exchange rate corresponding to the VOC measurements at each ventilation setting. The concentration levels and emission rates of the target VOCs varied by as much as two orders of magnitude across sites. Aldehyde and terpene compounds were typically the chemical classes with highest concentrations, followed by alkanes, aromatics, and siloxanes. For each home, VOC concentrations tended to decrease as the air exchange rate was increased, however, measurement uncertainty was significant. The indoor concentration was inversely proportional to air exchange rate for most compounds. For a subset of compounds including formaldehyde, however, the indoor concentration exhibited a non-linear dependence on the timescale for air exchange