Search NASA⌕ Search

Engineering topics

Russell, Nick

Publications and source records attributed to Russell, Nick.

NSUF BOILER Pre-Irradiation Characterization and High Flux Isotope Reactor Experiment Design

Alumina-forming austenitic (AFA) stainless steels have emerged as a candidate alloy because of their high-temperature strength, formability, cost, and compatibility with primary coolants for lead-cooled fast reactors (LFRs). This class of steels has exceptional high-temperature oxidation performance; however, a high concentration of Ni is required to stabilize the austenite phase and to provide sufficient creep strength. AFA stainless steels are also susceptible to liquid metal embrittlement (LME). Additionally, under neutron irradiation, Ni will enrich at grain boundaries due to radiation-induced segregation (RIS). Nickel RIS can increase the LME under these coupled effects. Oak Ridge National Laboratory (ORNL) and the NSUF program have leveraged its High Flux Isotope Reactor (HFIR) and experience with complex irradiation experiments to design experiment capsules that test the aforementioned coupled effects. These capsules are designed for insertion in the central flux trap, the highest flux region, of HFIR. The experiment capsules will be filled with Pb, designed to passively melt from the gamma heating in HFIR. The specimens were fabricated into miniature tensile specimens from two different alloys, GA05-25Ni and GA05-20Ni, varying Ni concentrations. The experiment capsules are designed to achieve target temperatures of 400 °C and 650 °C with accumulated dosage of 3 dpa. This report documents the specimen alloy characterization, experimental design, and expected performance of the capsules.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Testing of an Optical Fiber--Based Gamma Thermometer in the High Flux Isotope Reactor Gamma Irradiation Facility

This report describes the design, thermal modeling, and gamma irradiation testing of an optical fiber–based gamma thermometer (OFBGT), which was irradiated in the High Flux Isotope Reactor (HFIR) Gamma Irradiation Facility (GIF). OFBGTs are a promising technology for application in nuclear reactors because they can provide a distributed measurement of gamma ray heating rate, unlike thermocouple-based gamma thermometers, which are fixed in-core sensors that can be used in boiling water reactors to calibrate local power range monitors. OFBGTs measure gamma ray heating rate by measuring the temperature difference between a pair of optical fibers; one fiber is in thermal contact with a heat sink (usually the reactor coolant), and the other is in thermal contact with a thermally isolated mass. The device can be calibrated with a heating wire within the thermal mass. The OFBGT that was designed and fabricated at Oak Ridge National Laboratory can measure distributed gamma ray heating rate over an effective measurement length of 61 cm, and the outer diameter of the sensor is 12.7 mm, giving the prototypical sensor design a relatively small footprint. The sensor housing is backfilled with Ar to ensure a well-predicted thermal response that is not affected by humidity or chemical interactions during operation. For calibration, the sensor design uses a Ni–Cr wire, which can be supplied with currents from 0 to 1 A to capture the wide range of potential gamma ray heating rates expected in HFIR’s spent fuel elements. The OFBGT was thermally modeled analytically and numerically; both models account for temperature-dependent thermal conductivities of the materials and show good agreement. The thermal response of the sensor inside spent HFIR fuel elements was simulated for times up to 1 year after discharge of the fuel element. Out-of-pile open-air tests indicated that the steady-state response of the sensor matches modeled results within experimental uncertainty. Calibration tests were performed using electrical heating in the HFIR spent fuel pool, above the fuel elements, to establish a relationship between the difference in spectral shift measured by optical fibers located inside and outside the OFBGT and the applied electrical heating. Subsequently, the OFBGT was placed within the the spent fuel element from HFIR cycle 501 to measure the spatial profile of the gamma heating rates. Results showed good agreement between the theoretical and measured gamma dose rate profiles, with maximum deviations of ~10% or less.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Volume 10: Flow Test Facilities

Adding additional flow testing facilities has been considered as part of the High Flux Isotope Reactor (HFIR) Sustaining and Enhancing Neutron Science (SENSe) Initiative at Oak Ridge National Laboratory (ORNL) to support HFIR operations and experiments. This prospect has prompted many ideas and discussions regarding potential features, configurations, locations, and applications for the facilities. A working group of ORNL staff members was formed in fiscal year 2022 to recommend one or more configurations to best support future HFIR operations and scientific capacities and to develop order-of magnitude cost estimates and timing. The ideas discussed in this report include options ranging from upgrading existing small-scale testing facilities to building a full-scale HFIR mockup for detailed thermohydraulic testing and fuel assessment.

07 ISOTOPE AND RADIATION SOURCES↗