Defect Characterization in a Thin Walled Composite RP-1 Tank: A Case Study

A full scale thin walled composite tank, designed and fabricated for the storage of pressurized RP- I rocket fuel, was fully inspected with digital infrared thermography (IR) during assembly and prior to proof testing. The tank featured a "pill capsule" design with the equatorial bondline being overwrapped on both the inner and outer surfaces. A composite skirt was bonded to the aft dome of the tank to serve as a structural support when the tank was stood on end in service. Numerous anomalies were detected and mapped prior to proof testing, some along bondlines and some scattered throughout the acreage. After the tank was intentionally burst, coupons were cut from the regions including thermographic anomalies. These coupons were again inspected thermographically to document the growth of any indications due to proof testing. Ultrasonic inspections (UT) were also performed on the coupons for comparison to thermography. Several coupons were dissected and micrographed. Relationships between IR and UT indications and the physical nature of the dissected material are presented.

Langsing, Matthew D.↗

Thermographic Analysis of Composite Cobonds on the X-33

The methods utilized to perform an infrared thermography inspection of the bondline of structural reinforcing caps on X-33 liquid hydrogen (LH2) tank during the manufacture are described in this presentation. A total of thirty-six caps were bonded to the tank using a wet cobond process with vacuum bagging and low temperature curing. The thermal map of each bondline was acquired through the vacuum bag by applying heat to the cap and then viewing it during cool down. Poorly bonded regions, or voids, were characterized by localized hot spots in the thermal image. These regions were marked on the tank by referring to a live thermal image, then hand massaged in an attempt to remove the entrapped air. The cap was then reinspected and, if it was determined that the entrapped air could not be removed, the cap was removed and the adhesive cleaned away before it cured. Measures were then taken to better match the surface of the cap to the tank and the process repeated. After the bondline had cured sufficiently to allow vacuum bag removal, a "flash heating" thermographic Investigation was performed to verify that the cap had bonded properly to the tank. Any regions that had opened up after the preliminary inspection were marked and filled by drilling small holes in the cap and injecting resin. A final inspection was then performed to ensure the quality of the bondline.

Russell, Samual S.↗