Search NASA⌕ Search

Engineering topics

Russo, P.

Publications and source records attributed to Russo, P..

Accurate and Simple Parametrization to Estimate Solar UV from GHI and Other Accessible Variables

This study is part of a broader program that aims to generate reliable ultraviolet (UV) data for several applications. This work presents a simple and fast parametrization to estimate UV solar irradiation at the ground level from global horizontal irradiance (GHI) information. The work focuses on UVB (280-315 nm) and erythemic UV (UVE) irradiance weighted by the average skin response.

GHI↗

Analysis of Integrated Fuselage Composite Seat for Small Aircraft in Crashworthiness Applications

The research paper is addressed to develop and validate an aircraft seat cushion to be used for the passenger seat directly integrated in the fuselage. For very light aircraft, these systems result to be a good choice in terms of weight reduction and space optimization, but can represent a challenging problem for crashworthiness design and a key energy-absorbing function for human protection from injuries so to improve the level of the safety. The first issue was dedicated to investigate the mechanical properties of four commercial foams, diffused in different industrial applications, which present nonlinear and time-dependent viscoelastic behavior, and finally to determine whether typical seat cushion materials are rate sensitive or not. Then, numerical simulations were validated with measurements to simulate the mechanical properties of foams and to evaluate the contact pressures, stress distribution, and the dependence of stress on the strain rate in order to provide adequate levels of both comfort and energy absorption.

36 MATERIALS SCIENCE↗

Energy dependent calibration of XR-QA2 radiochromic film with monochromatic and polychromatic x-ray beams

Purpose: This work investigates the energy response and dose-response curve determinations for XR-QA2 radiochromic film dosimetry system used for synchrotron radiation work and for quality assurance in diagnostic radiology, in the range of effective energies 18–46.5 keV. Methods: Pieces of XR-QA2 films were irradiated, in a plane transverse to the beam axis, with a monochromatic beam of energy in the range 18–40 keV at the ELETTRA synchrotron radiation facility (Trieste, Italy) and with a polychromatic beam from a laboratory x-ray tube operated at 80, 100, and 120 kV. The film calibration curve was expressed as air kerma (measured free-in-air with an ionization chamber) versus the net optical reflectance change (netΔR) derived from the red channel of the RGB scanned film image. Four functional relationships (rational, linear exponential, power, and logarithm) were tested to evaluate the best curve for fitting the calibration data. The adequacy of the various fitting functions was tested by using the uncertainty analysis and by assessing the average of the absolute air kerma error calculated as the difference between calculated and delivered air kerma. The sensitivity of the film was evaluated as the ratio of the change in net reflectance to the corresponding air kerma. Results: The sensitivity of XR-QA2 films increased in the energy range 18–39 keV, with a maximum variation of about 170%, and decreased in the energy range 38–46.5 keV. The present results confirmed and extended previous findings by this and other groups, as regards the dose response of the radiochromic film XR-QA2 to monochromatic and polychromatic x-ray beams, respectively. Conclusions: The XR-QA2 radiochromic film response showed a strong dependence on beam energy for both monochromatic and polychromatic beams in the range of half value layer values from 0.55 to 6.1 mm Al and corresponding effective energies from 18 to 46.5 keV. In this range, the film response varied by 170%, from a minimum sensitivity of 0.0127 to a maximum sensitivity of 0.0219 at 10 mGy air kerma in air. The more suitable function for air kerma calibration of the XR-QA2 radiochromic film was the power function. A significant batch-to-batch variation, up to 55%, in film response at 120 kV (46.5 keV effective energy) was observed in comparison with published data.

61 RADIATION PROTECTION AND DOSIMETRY↗

A SURVEY OF ASTRONOMICAL RESEARCH: A BASELINE FOR ASTRONOMICAL DEVELOPMENT

Measuring scientific development is a difficult task. Different metrics have been put forward to evaluate scientific development; in this paper we explore a metric that uses the number of peer-reviewed, and when available non-peer-reviewed, research articles as an indicator of development in the field of astronomy. We analyzed the available publication record, using the Smithsonian Astrophysical Observatory/NASA Astrophysics Database System, by country affiliation in the time span between 1950 and 2011 for countries with a gross national income of less than 14,365 USD in 2010. This represents 149 countries. We propose that this metric identifies countries in ''astronomical development'' with a culture of research publishing. We also propose that for a country to develop in astronomy, it should invest in outside expert visits, send its staff abroad to study, and establish a culture of scientific publishing. Furthermore, we propose that this paper may be used as a baseline to measure the success of major international projects, such as the International Year of Astronomy 2009.

79 ASTRONOMY AND ASTROPHYSICS↗

Imaging performance comparison between a LaBr{sub 3}:Ce scintillator based and a CdTe semiconductor based photon counting compact gamma camera

The authors report on the performance of two small field of view, compact gamma cameras working in single photon counting in planar imaging tests at 122 and 140 keV. The first camera is based on a LaBr{sub 3}:Ce scintillator continuous crystal (49x49x5 mm{sup 3}) assembled with a flat panel multianode photomultiplier tube with parallel readout. The second one belongs to the class of semiconductor hybrid pixel detectors, specifically, a CdTe pixel detector (14x14x1 mm{sup 3}) with 256x256 square pixels and a pitch of 55 {mu}m, read out by a CMOS single photon counting integrated circuit of the Medipix2 series. The scintillation camera was operated with selectable energy window while the CdTe camera was operated with a single low-energy detection threshold of about 20 keV, i.e., without energy discrimination. The detectors were coupled to pinhole or parallel-hole high-resolution collimators. The evaluation of their overall performance in basic imaging tasks is presented through measurements of their detection efficiency, intrinsic spatial resolution, noise, image SNR, and contrast recovery. The scintillation and CdTe cameras showed, respectively, detection efficiencies at 122 keV of 83% and 45%, intrinsic spatial resolutions of 0.9 mm and 75 {mu}m, and total background noises of 40.5 and 1.6 cps. Imaging tests with high-resolution parallel-hole and pinhole collimators are also reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗