Search NASA⌕ Search

Engineering topics

Rybka, Gray

Publications and source records attributed to Rybka, Gray.

Larmor power limit for cyclotron radiation of relativistic particles in a waveguide

Cyclotron radiation emission spectroscopy (CRES) is a modern technique for high-precision energy spectroscopy, in which the energy of a charged particle in a magnetic field is measured via the frequency of the emitted cyclotron radiation. The He6-CRES collaboration aims to use CRES to probe beyond the standard model physics at the TeV scale by performing high-resolution and low-background beta-decay spectroscopy of 6 He and 19 Ne. Having demonstrated the first observation of individual, high-energy (0.1–2.5 MeV) positrons and electrons via their cyclotron radiation, the experiment provides a novel window into the radiation of relativistic charged particles in a waveguide via the time-derivative (slope) of the cyclotron radiation frequency, df c /dt. We show that analytic predictions for the total cyclotron radiation power emitted by a charged particle in circular and rectangular waveguides are approximately consistent with the Larmor formula, each scaling with the Lorentz factor of the underlying e ± as γ 4 . This hypothesis is corroborated with experimental CRES slope data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Axions beyond Gen 2

The QCD (Quantum ChromoDynamics) axion emerged as one of the best-motivated dark matter candidates. In 2018, the Axion Dark Matter eXperiment (ADMX), one of the U.S. Department of Energy’s “Gen 2” flagship dark-matter projects, demonstrated first sensitivity to the highly plausible “DFSZ” dark matter axion couplings over a small frequency range. We anticipate this development marks the first step in constructing yet more powerful experiments that can explore large swaths of the axion parameter space at high sensitivity and result in a discovery. But, realizing this requires advances in both our understanding of the theory and experiment design. Between 25 January and 27 January 2021, the “Axions Beyond Gen 2 Workshop” was held, where selected members of the community discussed our broad understanding of the QCD axion and charted a course for future experiments having sensitivity and mass reach well beyond the current “Gen 2” experiments. These proceedings are summaries of the topics presented and discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multi-mode analysis of surface losses in a superconducting microwave resonator in high magnetic fields

This paper reports on a surface impedance measurement of a bulk metal niobium–titanium superconducting radio frequency (SRF) cavity in a magnetic field (up to 10 T). Here, a novel method is employed to decompose the surface resistance contributions of the cylindrical cavity end caps and walls using measurements from multiple TM cavity modes. The results confirm that quality factor degradation of a NbTi SRF cavity in a high magnetic field is primarily from surfaces perpendicular to the field (the cavity end caps), while parallel surface resistances (the walls) remain relatively constant. This result is encouraging for applications needing high Q cavities in strong magnetic fields, such as the Axion Dark Matter eXperiment because it opens the possibility of hybrid SRF cavity construction to replace conventional copper cavities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Snowmass Cosmic Frontier Report

This report summarizes the current status of Cosmic Frontier physics and the broad and exciting future prospects identified for the Cosmic Frontier as part of the 2021 Snowmass Process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Axion dark matter experiment: Run 1B analysis details

Searching for axion dark matter, the ADMX Collaboration acquired data from January to October 2018, over the mass range 2.81–3.31 μeV, corresponding to the frequency range 680–790 MHz. Using an axion haloscope consisting of a microwave cavity in a strong magnetic field, the ADMX experiment excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions at 90% confidence level and 100% dark matter density over this entire frequency range, except for a few gaps due to mode crossings. This paper explains the full ADMX analysis for run 1B, motivating analysis choices informed by details specific to this run.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron radiated power in cyclotron radiation emission spectroscopy experiments

The recently developed technique of Cyclotron Radiation Emission Spectroscopy (CRES) uses frequency information from the cyclotron motion of an electron in a magnetic bottle to infer its kinetic energy. Here we derive the expected radio-frequency signal from an electron in a waveguide CRES apparatus from first principles. We demonstrate that the frequency-domain signal is rich in information about the electron's kinematic parameters and extract a set of measurables that in a suitably designed system are sufficient for disentangling the electron's kinetic energy from the rest of its kinematic features. This lays the groundwork for high-resolution energy measurements in future CRES experiments, such as the Project 8 neutrino mass measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Piezoelectrically Tuned, Multimode Cavity Search for Axion Dark Matter

The eV axion is a well-motivated extension to the standard model. The Axion Dark Matter 27 eXperiment (ADMX) collaboration seeks to discover this particle by looking for the resonant con28 version of dark-matter axions to microwave photons in a strong magnetic eld. In this paper we 29 report results from an ADMX pathnder experiment, the ADMX \Sidecar", which is designed to 30 pave the way for future, higher mass, searches. The Sidecar experiment excludes masses in three 31 widely spaced frequency ranges (4202-4249 MHz, 5086-5799 MHz and 7173-7203 MHz), correspond32 ing to masses favored by some cosmic string simulations. In addition, Sidecar demonstrates the 33 successful use of piezoelectric actuators for both cavity tuning and antenna coupling. Finally, this publication is the rst to report data taken on both the TM010 and TM020 modes.

Boutan, Christian R.↗

Listening for Dark Matter with ADMX

The Axion Dark Matter Experiment (ADMX) is on the hunt for theoretical particles called axions, which may solve the dark matter mystery. ADMX, managed by Fermilab and housed at the University of Washington, is the first and only experiment of its type with the sensitivity to detect axion dark matter particles. For more information, please visit https://news.fnal.gov/2018/04/admx-announces-breakthrough-in-axion-dark-matter-detection-technology/ and https://www.fnal.gov/pub/science/particle-physics/experiments/admx.html

79 ASTRONOMY AND ASTROPHYSICS↗

Laboratory searches for $\mathrm{QCD}$ axion dark matter

The QCD axion, originally proposed as a solution to the strong-CP problem, is one of the most promising dark matter candidates. Only now after decades of development are experimental techniques beginning to probe the most promising dark matter axion parameter space. In addition new ideas are being developed to expand the search for axion dark matter to cover the entire plausible range of axion masses. The state of the current laboratory-based axion searches based on the established haloscope and developing NMR techniques are noted here along with some of the astrophysical searches relevant to dark matter axions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determining the neutrino mass with cyclotron radiation emission spectroscopy—Project 8

The most sensitive direct method to establish the absolute neutrino mass is observation of the endpoint of the tritium beta-decay spectrum. Cyclotron radiation emission spectroscopy (CRES) is a precision spectrographic technique that can probe much of the unexplored neutrino mass range with ${ \mathcal O }(\mathrm{eV})$ resolution. A lower bound of $m({\nu }_{e})\gtrsim 9(0.1)\,\mathrm{meV}$ is set by observations of neutrino oscillations, while the KATRIN experiment—the current-generation tritium beta-decay experiment that is based on magnetic adiabatic collimation with an electrostatic (MAC-E) filter—will achieve a sensitivity of $m({\nu }_{e})\lesssim 0.2\,\mathrm{eV}$. The CRES technique aims to avoid the difficulties in scaling up a MAC-E filter-based experiment to achieve a lower mass sensitivity. Here in this paper we review the current status of the CRES technique and describe Project 8, a phased absolute neutrino mass experiment that has the potential to reach sensitivities down to $m({\nu }_{e})\lesssim 40\,\mathrm{meV}$ using an atomic tritium source.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Limits on axion–photon coupling or on local axion density: Dependence on models of the Milky Way’s dark halo

The μV-scale axion is a compelling cold dark matter candidate. The Axion Dark Matter eXperiment (ADMX) searches for axions by stimulating the decay of galactic dark matter halo axions into detectable microwave photons by their conversion in a resonant cavity permeated by a strong, static magnetic field. The signal depends on properties of the Milky Way’s dark matter halo; the choice of halo model has significant implications for the sensitivity of direct detection searches, e.g., ADMX. This work explores the sensitivity of the data taken by ADMX from 2008 to 2010 to various dark matter halo models. New models for the phase-space distribution of local axions are considered; the analysis demonstrates that certain assumptions about the dark matter halo improve limits on axion–photon coupling. In addition, new ADMX data covering 860–892 MHz are included in the analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single-electron detection and spectroscopy via relativistic cyclotron radiation

It has been understood since 1897 that accelerating charges should emit electromagnetic radiation. Cyclotron radiation, the particular form of radiation emitted by an electron orbiting in a magnetic field, was first derived in 1904. Despite the simplicity of this concept, and the enormous utility of electron spectroscopy in nuclear and particle physics, single-electron cyclotron radiation has never been observed directly. Here we demonstrate single-electron detection in a novel radiofrequency spectrometer. We observe the cyclotron radiation emitted by individual electrons that are produced with mildly-relativistic energies by a gaseous radioactive source and are magnetically trapped. The relativistic shift in the cyclotron frequency permits a precise electron energy measurement. Precise beta electron spectroscopy from gaseous radiation sources is a key technique in modern efforts to measure the neutrino mass via the tritium decay endpoint, and this work is a proof-of-concept for future neutrino mass experiments using this technique.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Project 8: Precision Electron Specroscopy to Measure the Mass of the Neutrino

The Project 8 Collaboration is exploring a new technique for the spectroscopy of medium-energy electrons (* 1 – 100 keV) with the ultimate goal of measuring the effective mass of the electron antineutrino by the tritium endpoint method. Our method is based on the detection of microwave-frequency cyclotron radiation emitted by magnetically trapped electrons. The immediate goal of Project 8 is to demonstrate the utility of this technique for a tritium endpoint experiment through a high-precision measurement of the conversion electron spectrum of 83mKr. We present concepts for detecting this cyclotron radiation, focusing on a guided wave design currently being implemented in a prototype apparatus at the University of Washington.

neutrino, tritium, beta decay, krypton-83, convers↗

Exotic Physics with ADMX

The Axion Dark Matter Experiment (ADMX) is an axion haloscope intended to search for local dark matter axions through their resonant conversion to microwave photons. As such, it is extremely sensitive to any particle that couples weakly to microwave photons. Preliminary results from a search for scalar chameleons and plans for a search for a two cavity search for hidden sector photons are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗