Enhancing Electrochemical Sensing through Molecular Engineering of Reduced Graphene Oxide–Solution Interfaces and Remote Floating-Gate FET Analysis
Not Available
Engineering topics
Publications and source records attributed to Ryu, Byunghoon.
Not Available
Rapid diagnosis of coronavirus disease 2019 (COVID-19) is key for the long-term control of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) amid renewed threats of mutated SARS-CoV-2 around the world. Here, we report on an electrical label-free detection of SARS-CoV-2 in nasopharyngeal swab samples directly collected from outpatients or in saliva-relevant conditions by using a remote floating-gate field-effect transistor (RFGFET) with a 2-dimensional reduced graphene oxide (rGO) sensing membrane. RFGFET sensors demonstrate rapid detection (<5 min), a 90.6% accuracy from 8 nasal swab samples measured by 4 different devices for each sample, and a coefficient of variation (CV) < 6%. Also, RFGFET sensors display a limit of detection (LOD) of pseudo-SARS-CoV-2 that is 10 000-fold lower than enzyme-linked immunosorbent assays, with a comparable LOD to that of reverse transcriptionpolymerase chain reaction (RT-PCR) for patient samples. To achieve this, comprehensive systematic studies were performed regarding interactions between SARS-CoV-2 and spike proteins, neutralizing antibodies, and angiotensin-converting enzyme 2, as either a biomarker (detection target) or a sensing probe (receptor) functionalized on the rGO sensing membrane. Finally, taken together, this work may have an immense effect on positioning FET bioelectronics for rapid SARS-CoV-2 diagnostics.
Heterogeneous nucleation could be an effective approach to producing an array of transition metal dichalco-genides (TMDs) at controlled locations on a substrate. In this study, we prepared Pt mesa structures on the substrate to induce heterogeneous nucleation of MoS 2 during chemical vapor deposition (CVD) and investigated the adsorption of nuclei using Monte Carlo (MC) simulations. The MC simulations suggest that the site-selectivity of MoS 2 dramatically drops when the CVD growth time goes beyond the critical time at which nuclei fully cover the Pt mesas, and such critical time can be delayed when the size of Pt mesas increases. Our experimental observations on a clean array of MoS 2 successfully synthesized on 10 um-width square Pt mesas but not on 4 um -width square Pt mesas support the MC simulation. We further designed a simple method employing dummy substrates to increase the yield of the site-selective MoS 2 array. Computational fluid dynamics (CFD) simulation reveals that such dummy substrates restrict the precursor concentration and provide a confined channel for the precursors to react slowly, which benefits producing large-area and site-selective MoS 2 . Furthermore, compared with conventional CVD, the total coverage of site-selective MoS 2 has enlarged by seven times using dummy substrates.
Despite intensive research of nanomaterials-based field-effect transistors (FETs) as a rapid diagnostic tool, it remains to be seen for FET sensors to be used for clinical applications due to a lack of stability, reliability, reproducibility, and scalability for mass production. In this work, we propose a remote floating-gate (RFG) FET configuration to eliminate device-to-device variations of two-dimensional reduced graphene oxide (rGO) sensing surfaces and most of the instability at the solution interface. Also, critical mechanistic factors behind the electrochemical instability of rGO such as severe drift and hysteresis were identified through extensive studies on rGO–solution interfaces varied by rGO thickness, coverage, and reduction temperature. rGO surfaces in our RFGFET structure displayed a Nernstian response of 54 mV/pH (from pH 2 to 11) with a 90% yield (9 samples out of total 10), coefficient of variation (CV) < 3%, and a low drift rate of 2%, all of which were calculated from the absolute measurement values. As proof-of-concept, we demonstrated highly reliable, reproducible, and label-free detection of spike proteins of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in a saliva-relevant media with concentrations ranging from 500 fg/mL to 5 μg/mL, with an R 2 value of 0.984 and CV < 3%, and a guaranteed limit of detection at a few pg/mL. Taken together, this new platform may have an immense effect on positioning FET bioelectronics in a clinical setting for detecting SARS-CoV-2.
Machine learning (ML) is becoming an effective tool for studying 2D materials. Taking as input computed or experimental materials data, ML algorithms predict the structural, electronic, mechanical, and chemical properties of 2D materials that have yet to be discovered. Such predictions expand investigations on how to synthesize 2D materials and use them in various applications, as well as greatly reduce the time and cost to discover and understand 2D materials. This tutorial review focuses on the understanding, discovery, and synthesis of 2D materials enabled by or benefiting from various ML techniques. Here, we introduce the most recent efforts to adopt ML in various fields of study regarding 2D materials and provide an outlook for future research opportunities. The adoption of ML is anticipated to accelerate and transform the study of 2D materials and their heterostructures.