Remote Sensing of Nitric Acid and Temperature via Design of Experiments, Chemometrics, and Raman Spectroscopy
Not Available
Engineering topics
Publications and source records attributed to Sadergaski, Luke R..
Not Available
In situ optical spectroscopy, spectropotentiometry, and multivariate analysis were applied to the Np(IV) nitrate system to better understand speciation and quantify HNO 3 concentration. Thin-layer spectropotentiometry, or spectroelectrochemistry, was leveraged to isolate and stabilize Np(IV) without compromising the solution conditions and generate representative Vis-NIR absorption spectra from 0.5 to 10 M HNO 3 and benchmark the corresponding Np(IV) molar absorptivity coefficients. Spectra were described with principal component analysis (PCA) to identify the purest Np(IV) absorbance spectra among other oxidation states [e.g., Np(V/VI)] at each acid concentration and then to identify the primary sources of variance within each Np(IV) spectrum with respect to Np(IV) nitrate complexes. Then, partial least-squares regression (PLSR) and support vector regression (SVR) models were built to predict HNO 3 concentration from the Np(IV) spectral data. The nonlinear SVR model outperformed the linear PLSR model for the HNO 3 concentration predictions. Finally, the inclusion of spectra collected in edge and center point HNO 3 concentrations in the calibration set was determined to be crucial for producing models with strong predictive capabilities. The multivariate approach used in this study makes it possible to quantify HNO 3 concentration solely based on Np(IV) absorption spectra, which is essential to quantifying processing streams in various online monitoring applications.
The multilab Intentional Forensics Venture is working to identify which stable elements (i.e., taggants) at trace concentrations relative to U would persist throughout the nuclear fuel cycle in a voluntary fuel tagging scheme. A taggant would provide the nuclear forensics community with a “barcode” to help identify nuclear materials found outside of regulatory control. A portion of this project was focused on reprocessing effects and determining which, if any, elements would coextract with U(VI) in standard Pu–U reduction extraction (PUREX) conditions. Elements with a propensity to coextract could, in theory, be used as taggants from a PUREX perspective. Although retention is not a performance requirement, the taggant signature would need to partition predictably from the U stream after the PUREX process to maintain forensic utility. This report documents results from several batch extraction studies with numerous trace elements from HNO 3 (1.5–5 M), with and without U(VI), into 30% tri-n-butyl phosphate (TBP) in kerosene. Extraction and back-extraction tests were used to evaluate nearly 60 elements in surrogate conditions for PUREX, and distribution coefficients (i.e., D-values) for most species were <0.1, indicating few species are likely to co-extract with U through PUREX. Additional studies are needed to optimize sample volumes and dilutions to dial in these low D-values. The D-values (D) were determined for several of the more promising elements, including Re and Se. Ultimately, we conclude that only a limited number of the ~ 60 elements investigated are extractable in the U stream of PUREX, based on measured D values, meaning most candidate elemental taggants would likely be lost at this stage of the nuclear fuel cycle, even when considering a range of acid concentrations.
An automated platform has been developed to assist researchers in the rapid development of optical spectroscopy sensors to quantify species from spectral data. This platform performs calibration and validation measurements simultaneously. Real-time, in situ monitoring of complex systems through optical spectroscopy has been shown to be a useful tool; however, building calibration models requires development time, which can be a limiting factor in the case of radiological or otherwise hazardous systems. While calibration time can be reduced through optimized design of experiments, this study approached the challenge differently through automation. The ATLAS (Automated Transient Learning for Applied Sensors) platform used pneumatic control of stock solutions to cycle flow profiles through desired calibration concentrations for multivariate model construction. Additionally, the transients between desired concentrations based on flow calculations were used as validation measurements to understand model predictive capabilities. This automated approach yielded an incredible 76% reduction in model development time and a 60% reduction in sample volume versus estimated manual sample preparation and static measurements. The ATLAS system was demonstrated on two systems: a three-lanthanide system with Pr/Nd/Ho representing a use case with significant overlap or interference between analyte signatures and an alternate system containing Pr/Nd/Ni to demonstrate a use case in which broad-band corrosion species signatures interfered with more distinct lanthanide absorbance profiles. Both systems resulted in strong model prediction performance (RMSEP < 9%). Lastly, ATLAS was demonstrated as a tool to simulate process monitoring scenarios (e.g., column separation) in which models can be further optimized to account for day-to-day changes as necessary (e.g., baseline correction). Ultimately, ATLAS offers a vital tool to rapidly screen monitoring methods, investigate sensor fusion, and explore more complex systems (i.e., larger numbers of species).
Raman spectra of three NpO 2 samples and two samples produced from a modified direct denitration (MDD) process were collected. The spectral features of the NpO 2 samples were consistent and indicated only NpO 2 . The spectra of the MDD samples indicated the presence of NpO 2 and an additional phase attributed to the neptunium binary oxide Np 2 O 5 . These Raman spectra are the first reported of Np 2 O 5 , and the proportions of these neptunium oxide phases varied within the samples, suggesting significant sample inhomogeneity. Peaks in the Raman spectra of Np 2 O 5 at 569 and 782 cm –1 were tentatively assigned to concerted, symmetric stretches of the neptunyl cations. Finally, laser-induced heating of regions in the MDD samples that were rich in Np 2 O 5 showed spectral features that indicated conversion to NpO 2 .
Partial least squares regression (PLSR) and support vector regression (SVR) models were optimized for the quantification of U(VI) (10–320 g L −1 ) and HNO 3 (0.6–6 M) by Raman spectroscopy with optimized calibration sets chosen by optimal design of experiments. The designed approach effectively minimized the number of samples in the calibration set for PLSR and SVR by selecting sample concentrations with a quadratic process model, despite complex confounding and covarying spectral features in the spectra. The top PLS2 model resulted in percent root mean square errors of prediction for U(VI), HNO 3 , and NO 3 − of 3.7%, 3.6%, and 2.9%, respectively. PLS1 models performed similarly despite modeling an analyte with a majority linear response (i.e., uranyl symmetric stretch) and another with more covarying vibrational modes (i.e., HNO 3 ). Partial least squares (PLS) model loadings and regression coefficients were evaluated to better understand the relationship between weaker Raman bands and covarying spectral features. Support vector machine models outperformed PLS1 models, resulting in percent root mean square error of prediction values for U(VI) and HNO 3 of 1.5% and 3.1%, respectively. The optimal nonlinear SVR model was trained using a similar number of samples (11) compared with the PLSR model, even though PLS is a linear modeling approach. The generic D-optimal design presented in this work provides a robust statistical framework for selecting training set samples in disparate two-factor systems. This approach reinforces Raman spectroscopy for the quantification of species relevant to the nuclear fuel cycle and provides a robust chemometric modeling approach to bolster online monitoring in challenging process environments.
Radioisotope production relies on complex chemical processes that must be performed in radiological hot cells or glove boxes because of the radioactive and otherwise hazardous materials being used. In these situations, optical sensors can provide real-time monitoring to users, which is unobtainable by more traditional methods. This study explores the use of calibration transfer methods to train a model on one instrument and date and then transfer it to another instrument of the same or different configuration on a different date. By performing laser-induced fluorescence measurements of Eu(III) and Sm(III) in 10 M LiCl over the course of 6 months using two disparate spectrometers and two different training sets, a strategy for calibrating and deploying models for online monitoring was established. Three transfer techniques were compared: direct standardization (DS), piecewise direct standardization (PDS), and external parameter orthogonalization (EPO). DS and PDS outperformed EPO for day-to-day transfers, and EPO was not effective for instrument-to-instrument transfers. Transferring the initial date’s full factorial model provided better prediction performance compared with retraining models the day of measurements using a D-optimal designed calibration set. For both day-to-day and instrument-to-instrument transfers, five Kennard–Stone selected samples were sufficient. Based on this choice, the initial-date, high-resolution spectrometer model was transferred to a lower-resolution, compact spectrometer 6 months later to monitor a simulated, real-time demonstration. Here, the combined predictions of the DS and PDS transferred models were able to accurately track the anticipated concentration profiles, maintaining root-mean-square error of prediction values below 10 ppm.