Search NASA⌕ Search

Engineering topics

Sagisaka, A

Publications and source records attributed to Sagisaka, A.

Electron energy transport in the thin foil driven by high contrast high intensity laser pulse

The fast electron spectrum was measured for the interaction between the thin foil and the relativistic optical high field. There were two components in the electron spectrum. The higher temperature component was almost explained by the ponderomotive formula T{sub e}[MeV] = 0.511({radical}(1+I{sub 18}{lambda}{sup 2}{sub {mu}m}/1.37)-1). The total electron spectrum including the lower temperature component was also explained by a simple model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative measurement of hard x-ray spectra for high intensity laser produced plasma

X-ray line spectra ranging from 17 to 77 keV were quantitatively measured with a Laue spectrometer, composed of a cylindrically curved crystal and a detector. Either a visible CCD detector coupled with a CsI phosphor screen or an imaging plate can be chosen, depending on the signal intensities and exposure times. The absolute sensitivity of the spectrometer system was calibrated using pre-characterized laser-produced x-ray sources and radioisotopes. The integrated reflectivity for the crystal is in good agreement with predictions by an open code for x-ray diffraction. The energy transfer efficiency from incident laser beams to hot electrons, as the energy transfer agency for specific x-ray line emissions, is derived as a consequence of this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser driven proton beam for the applications: toward ultra-high intensity and short pulse proton beam

As a benchmark experiment to realize a novel and compact laser driven proton accelerator whose significant features are high number density in a short pulse width (approxns), 2.4 MeV laser driven proton beam is stably focused at 1 Hz repetition rate by using a pair of permanent quadrupole magnets (PMQs) with large apertures whose diameters and field strengths are 3.5 cm and 55 T/m for the first and 2.3 cm and 60 T/m for the second magnets, respectively. The proton beam has been focused to a focal spot of 3x8 mm{sup 2} in horizontal and vertical direction (full width at half maximum) at 650approxmm from the source, which is well reproduced by the simulation. The further optimization of the focusing system will sure to pave a way to the novel proton accelerator with which we can investigate the physics appeared in the short time scale as well as that in a high energy density matter, oncology, astrophysics, and so on.

43 PARTICLE ACCELERATORS↗

Radiobiological study by using laser-driven proton beams

Particle acceleration driven by high-intensity laser systems is widely attracting interest as a potential alternative to conventional ion acceleration, including ion accelerator applications to tumor therapy. Recent works have shown that a high intensity laser pulse can produce single proton bunches of a high current and a short pulse duration. This unique feature of laser-ion acceleration can lead to progress in the development of novel ion sources. However, there has been no experimental study of the biological effects of laser-driven ion beams. We describe in this report the first demonstrated irradiation effect of laser-accelerated protons on human lung cancer cells. In-vitro A549 cells are irradiated with a proton dose of 20 Gy, resulting in a distinct formation of gamma-H2AX foci as an indicator of DNA double-strand breaks. This is a pioneering result that points to future investigations of the radiobiological effects of laser-driven ion beams. The laser-driven ion beam is apotential excitation source for time-resolved determination of hydroxyl (OH) radical yield, which will explore relationship between the fundamental chemical reactions of radiation effects and consequent biological processes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On-Target Contrast Diagnostic via Specular Reflectivity Measurement

High-power laser contrast is challenging to measure, especially in the real target irradiation conditions. We present a convenient and relatively simple contrast diagnostic technique based on the measurement of target specular reflectivity at full laser power. The reflectivity remains high even at intensities above 10{sup 19} W/cm{sup 2} in the case of a high-contrast prepulse-free laser. On the contrary, the specular reflectivity drops in the case of lower contrast, due to the beam break-up and increased absorption caused by the preformed plasma. The technique was demonstrated using three different laser systems with several contrast conditions: Astra (CLF, RAL), TiS laser at APRI, GIST, and J-KAREN (APRC, JAEA).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion spectrometer composed of time-of-flight and Thomson parabola spectrometers for simultaneous characterization of laser-driven ions

An ion spectrometer, composed of a time-of-flight spectrometer (TOFS) and a Thomson parabola spectrometer (TPS), has been developed to measure energy spectra and to analyze species of laser-driven ions. Two spectrometers can be operated simultaneously, thereby facilitate to compare the independently measured data and to combine advantages of each spectrometer. Real-time and shot-to-shot characterizations have been possible with the TOFS, and species of ions can be analyzed with the TPS. The two spectrometers show very good agreement of maximum proton energy even for a single laser shot. The composite ion spectrometer can provide two complementary spectra measured by TOFS with a large solid angle and TPS with a small one for the same ion source, which are useful to estimate precise total ion number and to investigate fine structure of energy spectrum at high energy depending on the detection position and solid angle. Advantage and comparison to other online measurement system, such as the TPS equipped with microchannel plate, are discussed in terms of overlay of ion species, high-repetition rate operation, detection solid angle, and detector characteristics of imaging plate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of laser-accelerated protons to the demonstration of DNA double-strand breaks in human cancer cells

We report the demonstrated irradiation effect of laser-accelerated protons on human cancer cells. In vitro (living) A549 cells are irradiated with quasimonoenergetic proton bunches of 0.8-2.4 MeV with a single bunch duration of 15 ns. Irradiation with the proton dose of 20 Gy results in a distinct formation of {gamma}-H2AX foci as an indicator of DNA double-strand breaks generated in the cancer cells. This is a pioneering result that points to future investigations of the radiobiological effects of laser-driven ion beams. Unique high-current and short-bunch features make laser-driven proton bunches an excitation source for time-resolved determination of radical yields.

61 RADIATION PROTECTION AND DOSIMETRY↗

Focusing and spectral enhancement of a repetition-rated, laser-driven, divergent multi-MeV proton beam using permanent quadrupole magnets

A pair of conventional permanent magnet quadrupoles is used to focus a 2.4 MeV laser-driven proton beam at a 1 Hz repetition rate. The magnetic field strengths are 55 and 60 T/m for the first and second quadrupoles, respectively. The proton beam is focused to a spot with a size of less than {approx}3x8 mm{sup 2} at a distance of 650 mm from the source. This result is in good agreement with the Monte Carlo particle trajectory simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Femtosecond laser driven high-flux highly collimated MeV-proton beam

Highlly collimated energetic protons whose energies are up to 4 MeV are generated by an intense femtosecond Titanium Sappheire laser pulse interacting with a 7.5, 12.5, and 25 {mu}m-thick Polyimide tape target and 5 {mu}m-thick copper target. We find no clear difference on the proton spectra from 7.5, 12.5, and 25 {mu}m Polyimide tape target. The highest conversion efficiency from laser energy into protons of {approx}3% is observed with a 7.5 {mu}m thick Polyimide target. The quality of the proton beam is good enough to obtain a clear projection image of a mesh having 10 {mu}m line and space structure, installed into the passage of the beam. We obtain clear vertical lines on the proton intensity profiles from the copper target, which are considered to be transferred from the surface of the copper target. From it, we can restrict the size of the proton emitting region to be {approx}20 {mu}m.

43 PARTICLE ACCELERATORS↗

Laser ion acceleration by a near-critical density target

Protons having energies up to 3.8 MeV are experimentally generated by the p-polarized, 45 fs, {approx}10{sup 19} W/cm{sup 2} laser pulse interacting with a near-critical plasma cloud produced by the irradiation of the amplified spontaneous emission (ASE) pedestal at an intensity of {approx}10{sup 13} W/cm{sup 2} onto a 7.5-{mu}m-thick polyimide foil target. The emission angle of the high-energy protons is shifted away from the target normal toward the laser-propagation direction of 45 deg. The mechanism which explains the proton generation from the near-critical plasma cloud is discussed using the two-dimensional (2D) particle-in-cell (PIC) simulation.

43 PARTICLE ACCELERATORS↗

Development of Laser-Driven Proton and Electron Sources Using APRI 100-TW Ti:Sapphire Laser System

At the Advanced Photonics Research Institute (APRI) in Korea, we have a Ti:sapphire laser system which delivers laser pulses of 100-TW peak power and 32-fs pulse duration at the repetition rate of 10 Hz. This laser facility is being used to develop compact laser-driven proton and electron sources. Energetic protons are produced by irradiating the laser pulse on a thin foil target made of copper and polyimide via the target normal sheath acceleration. Proton beam with maximum energy of up to 4 MeV was generated from a polyimide target, and showed high energy conversion efficiency from laser to proton energy. Generation of high-energy electron beams by the laser wakefield acceleration was performed by focusing the laser pulses onto a 4 mm-long He-gas jet. Quasi-monoenergetic electron beam with peak energy of 45 MeV and maximum energy of 130 MeV was produced. The quality and characteristics of electron beams are strongly dependent on the laser-plasma interaction length which depends on focal length of the focusing optics.

43 PARTICLE ACCELERATORS↗

Relativistic Tennis Using Flying Mirror

Upon reflection from a relativistic mirror, the electromagnetic pulse frequency is upshifted and the duration is shortened by the factor proportional to the relativistic gamma-factor squared due to the double Doppler effect. We present the results of the proof-of-principle experiment for frequency upshifting of the laser pulse reflected from the relativistic 'flying mirror', which is a wake wave near the breaking threshold created by a strong driver pulse propagating in underdense plasma. Experimentally, the wake wave is created by a 2 TW, 76 fs Ti:S laser pulse from the JLITE-X laser system in helium plasma with the electron density of {approx_equal}4-6x10{sup 19} cm{sup -3}. The reflected signal is observed with a grazing-incidence spectrograph in 24 shots. The wavelength of the reflected radiation ranges from 7 to 14 nm, the corresponding frequency upshifting factors are {approx}55-115, and the gamma-factors are y = 4-6. The reflected signal contains at least 3x10{sup 7} photons/sr. This effect can be used to generate coherent high-frequency ultrashort pulses that inherit temporal shape and polarization from the original (low-frequency) ones. Apart from this, the reflected radiation contains important information about the wake wave itself, e.g. location, size, phase velocity, etc.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Efficient production of a collimated MeV proton beam from a polyimide target driven by an intense femtosecond laser pulse

High-flux energetic protons whose maximum energies are up to 4 MeV are generated by an intense femtosecond titanium:sapphire laser pulse interacting with 7.5, 12.5, and 25 {mu}m thick polyimide tape targets. Laser pulse with an energy of 1.7 J and with a duration of 34 fs is focused with an f/3.4 parabolic mirror giving an intensity of 3x10{sup 19} W cm{sup -2}. The main pulse to amplified spontaneous emission (ASE) intensity contrast ratio is 2.5x10{sup 7}. The conversion efficiency from the laser energy into the proton kinetic energies is achieved to be {approx}3%, which is comparable to or even higher than those achieved in the previous works; using nanometer-thick targets, in combination with the short-pulse lasers that have almost the same pulse width and the intensity but different main pulse to ASE intensity contrast of {approx}10{sup 10} [Neely et al., Appl. Phys. Lett. 89, 021502 (2006)], in which the authors claim that the main mechanism is target normal sheath acceleration; or using the 7.5 {mu}m thick polyimide target, in combination with the short-pulse laser, which has almost the same pulse width and the intensity, but the main pulse to ASE intensity contrast ratio was controlled to be 2.5x10{sup 5} [Yogo et al., Phys. Rev. E 77, 016401 (2008)], in which the authors claim the efficient acceleration by the mechanism of the underdense plasma model. The contrast ratio of the present experiment is in between these two experiments. The possible mechanism of this regime is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Frequency multiplication of light back-reflected from a relativistic wake wave

A method of coherent high-frequency electromagnetic radiation generation, proposed by Bulanov, Esirkepov, and Tajima [Phys. Rev. Lett. 91, 085001 (2003)], is experimentally demonstrated. This method is based on the radiation frequency multiplication during reflection at a mirror flying with relativistic velocity. The relativistic mirror is formed by the electron density modulations in a strongly nonlinear wake wave, excited in an underdense plasma in the wake behind an ultrashort laser pulse. In our experiments, the reflection of a countercrossing laser pulse from the wake wave is observed. The detected frequency multiplication factor is in the range from 55 to 114, corresponding to a reflected radiation wavelength from 7 to 15 nm. This may open a way towards tunable high-intensity sources of ultrashort coherent electromagnetic pulses in the extreme ultraviolet and x-ray spectral regions. Parameters of the reflecting wake wave can be determined using the reflected radiation as a probe.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗