Search NASASearch

Engineering topics

Saha, Timo

Publications and source records attributed to Saha, Timo.

25 records · Page 2

The Constellation-X Spectroscopy X-ray Telescope: Recent Technology Development

We describe recent progress in the technology development program for the mirror system for the Constellation-X Spectroscopy X-ray Telescope (SXT). Development of this mirror represents a significant technology challenge, as it must provide a combination of large effective area (3 sq. m) and modest angular resolution (15 arc second half power diameter requirement; 5 arc second goal) with a limited mass allocation. The baseline design incorporates over 200 nested Wolter 1 mirrors. Each of these in turn is segmented in order to simplify handling of the mirrors and facilitate mass production. The X-ray reflecting surfaces are fabricated from thin, thermally formed glass sheets. Production improvements have yielded mirror segments that approach the performance requirement without the need for epoxy replication. A mounting and alignment approach incorporating piezoelectric actuators has been shown to manipulate mirror segments with the required precision without introducing significant distortion. Substantial improvements in metrology methodology have provided insights into the mirror segment forming and alignment processes. An X-ray demonstration of a mirror segment pair is planned for early 2006.

Petre, Robert

Technology Development for the Constellation-X Spectroscopy X-Ray Telescope

The Constellation-X Spectroscopy X-ray Telescope (SXT) is a large diameter, high throughput, grazing incidence imaging mirror system, designed to perform high sensitivity spectroscopy of cosmic X-ray sources in the 0.2-10.0 keV band. The baseline effective area requirement is -3 m# at 1 keV. The system-level angular-resolution requirement is a 15-arcseconds half-power diameter, with a 5-arcsecond goal. The effective area is attained through a modular design, involving the nesting of many confocal, thin-walled Wolter I mirror segments. Considerable progress has been made in developing thin, thermally formed, glass mirror substrates that meet or better the angular-resolution requirement. Several approaches to mounting and aligning reflector segments into a mirror system are under investigation. We report here on the progress of the SXT technology development program toward reaching the performance goals.

Petre, Robert

Optical Metrology for the Segmented Optics on the Constellation-X Spectroscopy X-Ray Telescope

We present the metrology requirements and metrology implementation necessary to prove out the reflector technology for the Constellation X(C-X) spectroscopy X-ray telescope (SXT). This segmented, 1.6m diameter highly nested Wolter-1 telescope presents many metrology and alignment challenges. In particular, these mirrors have a stringent imaging error budget as compared to their intrinsic stiffness; This is required for Constellation-X to have sufficient effective area with the weight requirement. This has implications for the metrology that can be used. A variety of contract and noncontact optical profiling and interferometric methods are combined to test the formed glass substrates before replication and the replicated reflector segments.The reflectors are tested both stand-alone and in-situ in an alignment tower.Some of these methods have not been used on prior X-ray telescopes and some are feasible only because of the segmented approach used on the SXT. Methods discussed include high precision coordinate measurement machines using very low force or optical probe axial interferometric profiling azimuthal circularity profiling and use of advanced null optics such as conical computer generated hologram (CGHs).

Content, David

Development of Mirror Segments for the Constellation-X Observatory

As NASA's next major X-ray observatory, Constellation-X will have a photon collection area of 30,000 sq cm at 1 keV, which, after folding other instrumental responses, translates into an effective area of 15,000 sq cm. The observatory consists of four identical satellites each of which carries a spectroscopic X-ray telescope mirror assembly (SXT) that is 1.6 m in diameter and has a focal length of 10 m and a collection area of 7,500 sq cm at 1 keV and an angular resolution of 15 sec. HPD (half-power diameter) at the system level. Each mirror assembly consists of a large number of mirror segments precisely assembled together. Our development of the mirror segments is divided into two steps. The first one is to develop the basic approach and fabricate segments within the constraints of existing infrastructure to meet the angular resolution requirement, but not mirror segment size requirement. We have all but successfully completed this part of the development. We are now on the verge of going into the second step, that is to fabricate mirror segments of larger sizes to reduce the number of segments that have to be aligned and integrated. In this paper, we report on the requirements and the development status of the mirror segments. These assembly and other requirements of the SXT are reported elsewhere.

Zhang, W.

Constellation-X Cylinder Figuring and Polishing Studies

In support of Goddard's Constellation-X mandrel manufacturing effort a series of fabrication experiments are being performed to determine a best approach. Currently, polishing immediately after diamond turning, produces a RMS surface roughness of 0.31 nm, on a nickel plated aluminum mandrel. Studies currently under way will incorporate an abrasive figuring step followed by a polishing operation. The current diamond turning, figuring and polishing procedures will be described and the results presented.

Waluschka, Eugene

Metrology and Alignment of Light Weight Grazing Incidence X-Ray Mirrors

Metrology and alignment of light weight X-ray optics have been a challenge for two reasons: (1) that the intrinsic mirror quality and distortions caused by handling can not be easily separated, and (2) the diffraction limits of the visible light become a severe problem at the order of one arc-minute. Traditional methods of using a normal incident pencil or small parallel beam which monitors a tiny fraction of the mirror in question at a given time can not adequately monitor those distortions. We are developing a normal incidence setup that monitors a large fraction, if not the whole, of the mirror at any given time. It will allow us to align thin X-ray mirrors to-an accuracy of a few arc seconds or to a limit dominated by the mirror intrinsic quality.

Zhang, William