Breakthroughs in Picometer Ultra-Stable Spatial Metrology Systems for Next Generation Telescopes

Goal is to discover and characterize habitable planet candidates around Sun-like stars. Need 10(exp -10) contrast between reflected earth like planet and sun like stars. Options are internal Coronagraphs (LUVOIR and Habex) and large starshades (Habex) which each have pros and cons. Coronagraphs require 10(exp -10)contrast stability which means the primary mirror must be stable to roughly 10 picometers RMS wavefront over an exposure(minutes). Simplistically: Primary mirror instabilities of 10 picometers in certain spatial frequencies look like planets!

Feinberg, Lee↗

Sub-Picometer Dynamic Measurements of a Diffuse Surface

Future space observatory missions are forecasting the need for sensing and controlling wave front error and system alignment stability to picometer scale. Picometer stability performance demands precision knowledge of the mirror and metering structure materials to the same degree. A high-speed electronic speckle pattern interferometer was designed and built to demonstrate measurements of both static and dynamic responses of picometer amplitudes in materials of diffuse surface subjected to very low energy disturbances. This paper describes the details of a test to impart a dynamic disturbance of picometer scale and measure the response of a composite material.The results of the test are also reported and show conclusively that sub-picometer scale effects can be accurately measured in an open test environment outside a vacuum chamber.

Saif, Babak↗

JWST Optical Telescope Element Center of Curvature Test

The James Webb Space Telescope (JWST) Optical Telescope Element (OTE) and Integrated Science Instrument Module (ISIM) completed element level integration and test programs and were integrated to the next level of assembly called OTE/ISIM (OTIS) at Goddard Space Flight Center (GSFC) in Greenbelt, Maryland in 2016. Before shipping the OTIS to Johnson Space Center (JSC) for optical test at cryogenic temperature a series of vibration and acoustic tests were performed. To help ensure that the OTIS was ready to be shipped to JSC an optical center of curvature (CoC) test was performed to measure changes in the mirror's optical performance to verify that the telescope's primary mirror was not adversely impacted by the environmental testing and help us in understanding potential anomalies identified during the JSC tests. The primary is a 6.5 meter diameter mirror consisting of 18 individual hexagonal segments. Each segment is an off-axis asphere. There are a total of three prescriptions repeated six times each. As part of the CoC test each segment was individually measured using a high-speed interferometer (HSI) designed and built specifically for this test. This interferometer is capable of characterizing both static and dynamic characteristics of the mirrors. The latter capability was used, with the aid of a vibration stinger applying a low-level input force, to measure the dynamic characteristic changes of the PM backplane structure. This paper describes the CoC test setup and both static and dynamic test results.

interferometer↗

New Method for Characterizing the State of Optical and Opto-Mechanical Systems

James Webb Space Telescope Optical Telescope Element (OTE) is a three mirror anastigmat consisting of a 6.5 m primary mirror (PM), secondary mirror (SM) and a tertiary mirror. The primary mirror is made out of 18 segments. The telescope and instruments will be assembled at Goddard Space Flight Center (GSFC) to make it the Optical Telescope Element-Integrated Science Instrument Module (OTIS). The OTIS will go through environmental testing at GSFC before being transported to Johnson Space Center for testing at cryogenic temperature. The objective of the primary mirror Center of Curvature test (CoC) is to characterize the PM before and after the environmental testing for workmanship. This paper discusses the CoC test including both a surface figure test and a new method for characterizing the state of the primary mirror using high speed dynamics interferometry.

Optical Testing↗

Measuring the In-Process Figure, Final Prescription, and System Alignment of Large Optics and Segmented Mirrors Using Lidar Metrology

The fabrication of large optics is traditionally a slow process, and fabrication capability is often limited by measurement capability. W hile techniques exist to measure mirror figure with nanometer precis ion, measurements of large-mirror prescription are typically limited to submillimeter accuracy. Using a lidar instrument enables one to measure the optical surface rough figure and prescription in virtuall y all phases of fabrication without moving the mirror from its polis hing setup. This technology improves the uncertainty of mirror presc ription measurement to the micron-regime.

Ohl, Raymond↗

Phase-Conjugate Mirror Removes Wave-Front Distortions

Phase-conjugate mirrors remove distortions or aberrations from wave fronts in laser beams. With help of mirrors, one obtains high-power laser beams of diffraction-limited quality. Potential applications include multistage laser systems.

Seery, Bernard D.↗

Acousto-Optical Imaging Spectropolarimeter

Imaging spectropolarimeter designed around acousto-optical tunable filter (AOTF) takes polarization-specific spectral images of solid surfaces, aerosols, and absorption and emission phenomena in gas phase, at wavelengths from 500 to 1,000 nm. Produces side-by-side spectral images in two mutually perpendicular polarizations, one corresponding to ordinary, other corresponding to extraordinary waves in acousto-optical material. Offers large aperture, high resolving power, and rapid tunability, with no moving parts.

Saif, Babak↗

Self-Heterodyne Laser-Spectrum Analyzer

Apparatus measures spectral widths of light emitted by GaAs or other narrow-linewidth diode lasers at wavelengths between 800 and 900 nm. Operating on quasi-homodyne of self-heterodyne principle, apparatus provides relatively high spectral resolution: measures spectral widths of order of 100 kHz. Fine spectral resolution of apparatus provides data relevant to use of AlGaAs diode lasers in such applications as coherent optical communication through free space and injection seeding of solid-state lasers. Also used to explore connections between lifetimes and spectral widths of diode lasers.

Saif, Babak↗