Search NASA⌕ Search

Engineering topics

Salatino, M.

Publications and source records attributed to Salatino, M..

BICEP/Keck. XX. Component-separated Maps of the Polarized Cosmic Microwave Background and Thermal Dust Emission Using Planck and BICEP/Keck Observations through the 2018 Observing Season

We present component-separated polarization maps of the cosmic microwave background (CMB) and Galactic thermal dust emission, derived using data from the BICEP/Keck experiments through the 2018 observing season and Planck. By employing a maximum-likelihood method that utilizes observing matrices, we produce unbiased maps of the CMB and dust signals. We outline the computational challenges and demonstrate an efficient implementation of the component map estimator. We show methods to compute and characterize power spectra of these maps, opening up an alternative way to infer the tensor-to-scalar ratio from our data. We compare the results of this map-based separation method with the baseline BICEP/Keck analysis. Our analysis demonstrates consistency between the two methods, finding an 84% correlation between the pipelines.

cosmic inflation↗

Advanced ACTPol Multichroic Polarimeter Array Fabrication Process for 150 mm Wafers

Advanced ACTPol (AdvACT) is a third-generation cosmic microwave background receiver to be deployed in 2016 on the Atacama Cosmology Telescope (ACT). Spanning five frequency bands from 25 to 280 GHz and having just over 5600 transition-edge sensor (TES) bolometers, this receiver will exhibit increased sensitivity and mapping speed compared to previously fielded ACT instruments. This paper presents the fabrication processes developed by NIST to scale to large arrays of feedhorn-coupled multichroic AlMn-based TES polarimeters on 150-mm diameter wafers. In addition to describing the streamlined fabrication process which enables high yields of densely packed detectors across larger wafers, we report the details of process improvements for sensor (AlMn) and insulator (SiN(sub x)) materials and microwave structures, and the resulting performance improvements.

Atacama Cosmology Telescope(ACT)↗

Design and Deployment of a Multichroic Polarimeter Array on the Atacama Cosmology Telescope

We present the design and the preliminary on-sky performance with respect to beams and pass bands of a multichroic polarimeter array covering the 90 and 146 GHz cosmic microwave background bands and its enabling broad-band optical system recently deployed on the Atacama Cosmology Telescope (ACT). The constituent pixels are feedhorn-coupled multichroic polarimeters fabricated at NIST. This array is coupled to the ACT telescope via a set of three silicon lenses incorporating novel broad-band metamaterial anti-reflection coatings. This receiver represents the first multichroic detector array deployed for a CMB experiment and paves the way for the extensive use of multichroic detectors and broad-band optical systems in the next generation of CMB experiments.

passbands↗

High-Density Superconducting Cables for Advanced ACTPol

Advanced ACTPol (AdvACT) is an upcoming Atacama Cosmology Telescope (ACT) receiver upgrade, scheduled to deploy in 2016, that will allow measure- ment of the cosmic microwave background polarization and temperature to the highest precision yet with ACT. The AdvACT increase in sensitivity is partly provided by an increase in the number of transition-edge sensors (TESes) per array by up to a factor of two over the current ACTPol receiver detector arrays. The high-density AdvACT TES arrays require 70 μ m pitch superconducting flexible cables (flex) to connect the detec- tor wafer to the first-stage readout electronics. Here, we present the flex fabrication process and test results. For the flex wiring layer, we use a 400-nm-thick sputtered alu- minum film. In the center of the cable, the wiring is supported by a polyimide substrate, which smoothly transitions to a bare (uncoated with polyimide) silicon substrate at the ends of the cable for a robust wedge wire-bonding interface. Tests on the first batch of flex made for the first AdvACT array show that the flex will meet the requirements for AdvACT, with a superconducting critical current above 1 mA at 500 mK, resilience to mechanical and cryogenic stress, and a room temperature yield of 97%.

transition-edge sensors (TESes)↗