Analysis of strategies to meet ASHRAE S241 infectious aerosol control targets by space type and region using EnergyPlus™ simulations

Professional organizations, such as ASHRAE, have recently proposed new voluntary standards for controlling infectious aerosols. Specifically, ASHRAE Standard 241 (S241) defines equivalent clean air targets for a range of space types that can be met through combinations of mitigation measures. This paper seeks to inform the selection of measures by space type and climate zone through building simulations that quantify the impacts of increased outdoor air ventilation; increasing filtration and/or adding germicidal ultraviolet (GUV) in the central heating, ventilation, and air-conditioning (HVAC) systems; or using portable air cleaners (PACs), upper room GUV, or whole room GUV approaches to increase equivalent clean air delivery. The measures are assessed individually and in practical combinations for their ability to meet S241 in four space types (offices, classrooms, dining areas, and healthcare waiting rooms) using prototype buildings modeled using EnergyPlus. The mitigation measures are compared holistically against baseline building operations using metrics for equivalent clean air, energy, and comfort. The results in this study show that single measures can meet S241 for offices with minimal impacts on energy and comfort, while either upper room GUV systems or combinations of measures such as MERV 13 HVAC filtration with PACs are needed to meet S241 for classrooms. The dining area and healthcare waiting room targets cannot be met in this study when assuming design occupancy and MS2 as the challenge agent, even when combining multiple measures together. This paper provides valuable considerations when designing measures to meet S241 for a range of spaces and scenarios.

GUV↗

Building ControlScore: General Service Administration Office Building Deployment

Improvements to building control systems can lead to energy savings and increased occupant comfort. In an optimized system, process variables such as air temperature will closely follow their desired setpoints and avoid excess energy use. Typically, experts must manually inspect individual control loops to identify poor performance and opportunities for improvement. However, this approach is difficult in modern buildings that have a prohibitively large number of controllers. To address this issue, Pacific Northwest National Laboratory (PNNL) created the ControlScore concept, which takes operating data from the many controllers within a building and generates standardized scores for each loop on a scale of 0 to 10 (a score of 0 indicates poor control, a score of 10 indicates good control). PNNL applied the Building ControlScore application to all available data from a General Services Administration office building within the period of January 1, 2023, to March 9, 2023. The building scored a 4.7 overall, with all 74 of the building’s loops fitting a roughly normal distribution centered around 5. These results indicate that the analyzed systems have below-average performance with room for improvement, especially in the poorly scored systems. Airflow loops tended to have much lower scores than zone temperature loops. The lowest and highest performing systems in the building section were identified, as were all loops with a score less than 1. While the ControlScore identifies loops and systems that aren’t meeting their designated setpoints, it does not indicate the cause of those issues. For example, consider a supply air terminal unit’s airflow loop that received a low score due to it delivering less air than specified by the setpoint. The lower-than-desired airflow could be due to equipment limitations (e.g., the terminal unit or duct serving is too small to accommodate that airflow), malfunctioning equipment (e.g., a stuck damper or bad sensor), or something else entirely. The ControlScore does not diagnose problems it simply identifies the symptoms that can be explored and addressed by building operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A General Purpose Real-Time Optimization Strategy Applied to Minimizing Simultaneous Heating and Cooling in Buildings

Supervisory control strategies in heating, ventilating, and air-conditioning (HVAC) systems hold the potential for significant energy savings but they are difficult to set up and often depend on unreliable sensor measurements. In this paper, we propose a sensor-free approach to minimizing the energy penalties due to simultaneous heating and cooling in variable-air-volume (VAV) systems with reheat. A general-purpose real-time optimizer is described that is easy to set-up and integrate with existing control logic. A cost function is derived that quantifies the simultaneous heating and cooling penalty that does not require any sensor measurements. The optimizer then minimizes this cost function by automatically adjusting the supply temperature setpoint in the air-handling unit. The paper describes the approach and shows results from application from field trials on a 27-zone building.

Salsbury, Timothy↗

Building ControlScore: Research Laboratory Building Deployment

Improvements to building control systems can lead to energy savings and increased occupant comfort. In an optimized system, process variables such as air temperature will closely follow their desired setpoints and avoid excess energy use. Typically, experts must manually inspect individual control loops to identify poor performance and opportunities for improvement. However, this approach is difficult in modern buildings that have a prohibitively large number of controllers. To address this issue, Pacific Northwest National Laboratory (PNNL) created the ControlScore tool which captures operating data from the many controllers within a building and generates standardized scores for each loop on a scale of 0 to 10 (a score of 0 indicates poor control, a score of 10 indicates good control).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Verification and Validation for Energy System Co-Design and Simulation

This project was only active for two months and was terminated due to a re-organization of the sponsoring initiative. The original purpose of the project was to develop and apply verification and validation (V&V) methodologies for the Energy System Co-Design with Multiple Objectives and Power Electronics (E-COMP) Initiative. This report summarizes the project and the work that was completed in the shortened time frame.

42 ENGINEERING↗