Search NASA⌕ Search

Engineering topics

Salvat, D. J.

Publications and source records attributed to Salvat, D. J..

Accessing new physics with an undoped, cryogenic CsI CEvNS detector for COHERENT at the SNS

We consider the potential for a 10 kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model (BSM). Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We considered tests of several BSM scenarios such as neutrino nonstandard interactions and accelerator-produced dark matter. This detector’s performance was also studied for relevant questions in nuclear physics and neutrino astronomy, namely the weak charge distribution of Cs and I nuclei and detection of neutrinos from a core-collapse supernova. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of Electron-Neutrino Charged-Current Cross Sections on 127 I with the COHERENT NaI$ν$E Detector

Using an 185-kg NaI[Tl] array, COHERENT has measured the inclusive electron-neutrino chargedcurrent cross section on 127 I with pion decay-at-rest neutrinos produced by the Spallation Neutron Source at Oak Ridge National Laboratory. Iodine is one the heaviest targets for which low-energy (≤ 50 MeV) inelastic neutrino-nucleus processes have been measured, and this is the first measurement of its inclusive cross section. After a five-year detector exposure, COHERENT reports a flux-averaged cross section for electron neutrinos of ${9.2}_{–1.8}^{+2.1}$ × 10 –40 cm 2 . This corresponds to a value that is ~41% lower than predicted using the MARLEY event generator with a measured Gamow-Teller strength distribution. In addition, the observed visible spectrum from charged-current scattering on 127 I has been measured between 10 and 55 MeV, and the exclusive zero-neutron and one-or-more-neutron emission cross sections are measured to be ${5.2}_{–3.1}^{+3.4}$ × 10 –40 and ${2.2}_{—2.2}^{+3.5}$ × 10 –40 cm 2 , respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Demonstration of sub-micron UCN position resolution using room-temperature CMOS sensor

High spatial resolution of ultracold neutron (UCN) measurement is of growing interest to UCN experiments such as UCN spectrometers, UCN polarimeters, quantum physics of UCNs, and quantum gravity. Here we utilize physics informed deep learning to enhance the experimental position resolution and to demonstrate sub-micron spatial resolutions for UCN position measurements obtained using a room-temperature CMOS sensor, extending our previous work that demonstrated a position uncertainty of 1.5 microns. We explore the use of the open-source software Allpix Squared to generate experiment-like synthetic hit images with ground-truth position labels. We use physics-informed deep learning by training a fully connected neural network (FCNN) to learn a mapping from input hit images to output hit position. The automated analysis for sub-micron position resolution in UCN detection combined with the fast data rates of current and next generation UCN sources will enable improved precision for future UCN research and applications.

10B nanometer thin film↗

Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap

The past two decades have yielded several new measurements and reanalysis of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the most precise lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magneto-gravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. In this work, the new measurement gives a free neutron lifetime of $τ_n$ = 876.3(2.4) stat (0.8) syst . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap

The past two decades have yielded several new measurements and reanalysis of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the most precise lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magnetogravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. The new measurement gives a free neutron lifetime of $τ_n$ = 876.3(2.4) stat (0.8) syst . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT

Here, we present results of several measurements of CsI[Na] scintillation response to 3–60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at the Spallation Neutron Source (SNS), have been reassessed. We discuss corrections for the identified systematic effects and update the respective uncertainty values. The impact of updated results on future precision tests of CEvNS is estimated. We scrutinize potential systematic effects that could affect each measurement. In particular we confirm the response of the H11934-200 Hamamatsu photomultiplier tube (PMT) used for the measurements presented in this study to be linear in the relevant signal scale region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗